Giving up knowledge is almost never a good idea: an interview with Dr Evan Zahn

Published online by Cambridge University Press:  30 October 2019

Sebastian Góreczny*
Affiliation:
Department of Cardiology, Polish Mother’s Memorial Hospital, Research Institute, Lodz, Poland Department of Cardiology, Colorado Children’s Hospital, Aurora, CO, USA
Evan M. Zahn
Affiliation:
Guerin Family Congenital Heart Program, Smidt Heart Institute and Department of Pediatrics, Cedars-Sinai Medical Center, Los Angeles, CA, USA
*
Author for correspondence: S. Góreczny MD, PhD, Department of Cardiology, Polish Mother’s Memorial Hospital, Research Institute, 281/289 Rzgowska St, 93-338 Lodz, Poland. Tel: +48 42 271 14 78; Fax: +48 42 271 14 70; E-mail: sebastiangoreczny@yahoo.pl
Rights & Permissions [Opens in a new window]

Extract

The history of congenital interventional cardiology has seen numerous groundbreaking innovations typically related to the introduction of a new device or a novel treatment technique. Similarly, imaging of cardiac defects has changed dramatically over the past decades, although some of the advancements have seemed to omit the catheterisation laboratories. Rotational angiography, one of the imaging techniques for guidance of cardiac catheterisation currently referred to as “advanced”, in fact was described already in 1960s.1 More recently its improved version, including three-dimensional reconstruction (3DRA), became a valuable intra-procedural imaging tool in interventional cardiology and neuroradiology.2 Dr Evan Zahn was one of the pioneers of 3DRA in the field of congenital cardiology, setting an example for many to follow. With his innovative publication and subsequent lecture at 2011 Pediatric and Adult Interventional Cardiac Symposium (PICS-AICS) on “The Emerging Use of 3-Dimensional Rotational Angiography in Congenital Heart Disease” he motivated many to explore benefits of this modality to strive for improved procedural outcomes and reduced patients’ burden of cardiac catheterisation3. I was one of those to take Dr Zahn’s thoughts and implement them into routine workflow.4–6 However, almost a decade after Dr Zahn shared his important work, despite tremendous efforts by teams from Utrecht, (Netherlands) and Columbus (Ohio, United States of America) to popularise 3D imaging in catheterisation laboratory during dedicated meetings, two-dimensional (2D) angiography does not seem to be threatened in many, otherwise-progressive, laboratories. During the recent 30th Japanese Pediatric Interventional Cardiology (JPIC) meeting I had the opportunity to ask Dr Zahn why giving up knowledge is almost never a good idea, what is technology’s natural order of things, and why the technology has to be more than just exciting, pretty, and new.

Information

Type
Interview
Copyright
© Cambridge University Press 2019 
Figure 0

Figure 1. A traditional bi-plane two-dimensional angiography in a patient after total cavo-pulmonary connection shows unobstructed flow through both pulmonary arteries (a and b). Three-dimensional reconstruction from rotational angiography provides views unattainable with 2D angiography allowing for diagnosis of a dog-bone like left pulmonary artery stenosis (c) and evaluation of stent implantation (d).

Figure 1

Figure 2. Three-dimensional reconstruction from rotational angiography in a patient after Norwood procedure with arch obstruction provides multiple views allowing for better understanding of the lesion including relation not the nearby branches (a–c). Additional “cut plane” tool reveals the full extent of the narrowing (d).

Figure 2

Figure 3. A bi-plane two-dimensional angiography in a patient after stenting of aortic coarctation shows unobstructed flow through the stent (a and b). Three-dimensional reconstruction from rotational angiography reveals vessel dissection (white arrow) not visible in traditional angiography (c and d).

Figure 3

Figure 4. Still fluoroscopic frames illustrate the test deployment of a self-expanding Alterra Adaptive Prestent (Edwards Lifesciences) within a three-dimensional soft rubber model of the right ventricular outflow tract (a–d). The model allows for the evaluation of the extent of device contact with vessel wall (e).