Concept and realization of a low-cost multi-target simulator for CW and FMCW radar system calibration and testing

Published online by Cambridge University Press:  13 February 2018

Werner Scheiblhofer*
Affiliation:
Institute for Communications Engineering and RF-Systems, Johannes Kepler University Linz, Altenbergerstr. 69, Linz A-4040, Austria
Reinhard Feger
Affiliation:
Institute for Communications Engineering and RF-Systems, Johannes Kepler University Linz, Altenbergerstr. 69, Linz A-4040, Austria
Andreas Haderer
Affiliation:
Inras GmbH, Altenbergerstr. 69, A-4040 Linz, Austria
Andreas Stelzer
Affiliation:
Institute for Communications Engineering and RF-Systems, Johannes Kepler University Linz, Altenbergerstr. 69, Linz A-4040, Austria
*
Author for correspondence: Werner Scheiblhofer, Email: werner.scheiblhofer@jku.at
Rights & Permissions [Opens in a new window]

Abstract

We present the realization of an frequency-modulated continuous-wave radar target simulator, based on a modulated-reflector radar system. The simulator, designed for the 24 GHz frequency band, uses low-cost modulated-reflector nodes and is capable to simultaneously generate multiple targets in a real-time environment. The realization is based on a modular approach and thus provides a high scalability of the whole system. It is demonstrated that the concept is able to simulate multiple artificial targets, located at user-selectable ranges and even velocities, utilized within a completely static setup. The characterization of the developed hardware shows that the proposed concept allows to dynamically and precisely adjust the radar cross-section of each single target within a dynamic range of 50 dB. Additionally, the provided range-proportional target frequency bandwidth makes the system perfectly suitable for fast and reliable intermediate frequency-chain calibration of multi-channel radar systems. Within this paper we demonstrate the application of the concept for a linear sweeped frequency-modulated continuous-wave radar. The presented approach is applicable to any microwave-based measurement system using frequency differences between transmit- and receive signals for range- and velocity evaluation, such as (non-)linear sweeped as well as pure Doppler radar systems.

Information

Type
Research Papers
Copyright
Copyright © Cambridge University Press and the European Microwave Association 2018 
Figure 0

Fig. 1. Schematic representation of the modulated reflector radar. On the left, a 24 GHz frontend of the radar module is sketched, where components in the gray box are in the focus of conducted calibration measurements. On the right, a modulated reflector node is depicted.

Figure 1

Fig. 2. Spectral domain representation of the MRR caused by two MRNs with different modulation frequencies and different distances.

Figure 2

Table 1. Comparison of signal components

Figure 3

Fig. 3. The core component of the MRN is a reflective phase shifter, realized with a single PIN-diode, depicted in (a) and (b). In (c) the front side of a reflector with one possible antenna configuration is shown.

Figure 4

Fig. 4. Magnitude (blue) and phase (red) of the gain of the reflective phase shifter by variation of the voltage, applied to the diode at $f_{{\rm c}}=24.125\, {\rm GHz}$.

Figure 5

Fig. 5. The Smith-chart shows selected courses of the reflection coefficient of the reflective phase shifter by variation of the applied voltage and frequency.

Figure 6

Fig. 6. The schematic setup of the VAMRN, using two MRN phase shifters is depicted in (a). In (b) a photography of the realized hardware with the connections to the antennas on the left side is shown.

Figure 7

Fig. 7. Magnitude (blue) and phase (red) of the gain of the VAMRN phase-shifting core, determined at $f_{{\rm c}}$.

Figure 8

Fig. 8. The Smith-chart of the VAMRN shows similar courses of the reflection coefficient compared with the single-MRN core.

Figure 9

Fig. 9. The top figure shows different measured slopes for the attenuation approach taking advantage of the VAMRNs dual phase-shifting circuity. In the bottom, the difference between the simulated and measured slopes is depicted stating only minimal error values over a wide range.

Figure 10

Fig. 10. RD interrogation sweep sequence with corresponding phase of modulation signal.

Figure 11

Fig. 11. Spectrum of a multi-target measurement setup using a single MRN supplied by up to three simultaneously modulation frequencies.

Figure 12

Fig. 12. A setup of the presented RTS for a measurement with four MRNs.

Figure 13

Table 2. System parameter set of the DUT

Figure 14

Fig. 13. Comparison of the normalized slope of the fundamental, second-, and third-order harmonics caused by different modulation signals.

Figure 15

Fig. 14. The spectrum, AoA, and RD map of a dynamic scenario is depicted. The RCS values are dependent on the simulated target distance and $G_{ {\rm MRN}}$.

Figure 16

Table 3. True, simulated and measured MRN distances

Figure 17

Fig. 15. On the top, the normalized magnitude over frequency with variation of the desired RCS and different anti-aliasing filter settings for a single channel is depicted. The difference of magnitude and phase between the channels for a constant RCS is shown in the bottom.

Figure 18

Table 4. Comparison of presented system with existing RTS