A multicenter investigation to characterize the risk for pathogen transmission from healthcare facility sinks

Published online by Cambridge University Press:  11 December 2018

Scott A. Gestrich
Affiliation:
Research Service, Louis Stokes Cleveland VA Medical Center, Cleveland, Ohio
Annette L. Jencson
Affiliation:
Research Service, Louis Stokes Cleveland VA Medical Center, Cleveland, Ohio
Jennifer L. Cadnum
Affiliation:
Research Service, Louis Stokes Cleveland VA Medical Center, Cleveland, Ohio
Scott H. Livingston
Affiliation:
Research Service, Louis Stokes Cleveland VA Medical Center, Cleveland, OhioCase Western Reserve University School of Medicine, Cleveland, Ohio
Brigid M. Wilson
Affiliation:
Geriatric Research, Education, and Clinical Center, Louis Stokes Cleveland VA Medical Center, Cleveland, Ohio
Curtis J. Donskey*
Affiliation:
Case Western Reserve University School of Medicine, Cleveland, OhioGeriatric Research, Education, and Clinical Center, Louis Stokes Cleveland VA Medical Center, Cleveland, Ohio
*
Author for correspondence: Curtis J. Donskey, MD, Geriatric Research, Education, and Clinical Center 1110W, Louis Stokes Cleveland VA Medical Center, 10701 East Boulevard, Cleveland, Ohio 44106. E-mail: Curtis.Donskey@va.gov
Rights & Permissions [Opens in a new window]

Abstract

In 4 hospitals, we demonstrated frequent dispersal of fluorescent tracer and fluoroquinolone-resistant gram-negative bacilli from sink drains to sink bowls and to surfaces outside the bowl. Fluorescent tracer dispersal correlated inversely with the depth of the sink bowl. Modifications in sink design could substantially reduce the risk for pathogen dissemination.

Information

Type
Concise Communication
Copyright
© 2018 by The Society for Healthcare Epidemiology of America. All rights reserved. 
Figure 0

Fig. 1Frequency of recovery of fluoroquinolone-resistant gram-negative bacilli from sink bowls and countertops at baseline (A) and after running the hot- and cold-water faucets for 30 seconds (B). The sink bowl and countertop were disinfected after the baseline cultures but before running the water.

Figure 1

Table 1Odds Ratios for Sink Design Features Associated with Dispersal of Fluorescent Gel from the Sink Drain by Running Water