A novel shock tube with a laser–plasma driver

Published online by Cambridge University Press:  13 September 2017

Y. Kai*
Affiliation:
Hochschule Emden/Leer, University of Applied Sciences, Institute for Laser and Optics, Constantiaplatz 4, Emden 26723, Germany Carl von Ossietzky University of Oldenburg, Institute of Physics, Oldenburg 26111, Germany
W. Garen
Affiliation:
Hochschule Emden/Leer, University of Applied Sciences, Institute for Laser and Optics, Constantiaplatz 4, Emden 26723, Germany
T. Schlegel
Affiliation:
Hochschule Emden/Leer, University of Applied Sciences, Institute for Laser and Optics, Constantiaplatz 4, Emden 26723, Germany
U. Teubner
Affiliation:
Hochschule Emden/Leer, University of Applied Sciences, Institute for Laser and Optics, Constantiaplatz 4, Emden 26723, Germany Carl von Ossietzky University of Oldenburg, Institute of Physics, Oldenburg 26111, Germany
*
Address correspondence and reprint requests to: Y. Kai, Institute of Physics, Carl von Ossietzky University of Oldenburg, Oldenburg 26111, Germany. E-mail: yun.kai@uni-oldenburg.de

Abstract

A novel method to generate shock waves in small tubes is demonstrated. A femtosecond laser is applied to generate an optical breakdown an aluminum film as target. Due to the sudden appearance of this non-equilibrium state of the target, a shock wave is induced. The shock wave is further driven by the expanding high-pressure plasma (up to 10 Mbar), which serves as a quasi-piston, until the plasma recombines. The shock wave then propagates further into a glass capillary (different square capillaries with hydraulic diameter D down to 50 µm are applied). Shock wave propagation is investigated by laser interferometry. Although the plasma is an unsteady driver, due to the geometrical confinement of the capillaries, rather strong micro shocks can still propagate as far as 35 times D. In addition to the experiments, the initial conditions of this novel method are investigated by hydrocode simulations using MULTI-fs.

Information

Type
Research Article
Copyright
Copyright © Cambridge University Press 2017 
Figure 0

Fig. 1. Illustration of the LIMS method. In reality the target (1 mm thick glass substrate with a 50 nm thin Al-layer) is in close vicinity ($ \lt 5\, {\rm \mu} {\rm m}$, but not in contact) to the capillary entrance, the sketch is exaggerated for clear viewing.

Figure 1

Fig. 2. MULTI-fs simulation of the density development of LIMS at initial stage (t from 0 to 1 ns). Different time steps correspond to different color.

Figure 2

Fig. 3. MULTIfs simulation of the pressure development of the LIMS at initial stage.

Figure 3

Fig. 4. Wave diagram of the LIMS at initial stage, retrieved from the simulated data in Figures 2 and 3. ‘den. pro.’ is short for density profile, while ‘pres. pro.’ for pressure profile.

Figure 4

Fig. 5. Shock wave velocity development of the LIMS at initial stage. Retrieved from the MULTI-fs simulation data of the flow velocity.

Figure 5

Fig. 6. Shock wave ‘t–x’ diagram determined by LDI. Straight dash lines indicates sound wave propagation. The laser intensity is the same for all experiments. Extrapolation of the 200 µm capillary is made till sound wave propagation.

Figure 6

Fig. 7. Shock wave velocity attenuation. Simulated data replotted from Figure 5. Experimental data determined by (1) the time-of-flight method (scattered points with 10% error bars). and (2) the derivative of the fit of the trajectory (solid lines). The laser intensity is the same for all experiments.

Figure 7

Fig. 8. The development of the density jump across the shock in the 50 µm capillary. The error bars here correspond to the standard deviation resulted from the shot-to-shot errors.

Figure 8

Fig. 9. The normalized oscillograms corresponding to the shock detections in the 50 µm capillary.

Figure 9

Fig. 10. Illustration of the detection of a shock wave using the LDI. The oscillograph is taken at $x = 1000 \,{\rm \mu} {\rm m}$ in the 50 µm capillary. The sharp rising and falling edges are caused by the shock wave. The dotted circles highlight the expansion wave signal.

Figure 10

Fig. 11. Illustration of gas propagating through a stagnate shock wave in a capillary. The shock-fixed reference frame is applied.

Figure 11

Fig. 12. Velocity of the shock induced mass motion plotted against the propagation distance. Derived from the trajectory fit.

Figure 12

Fig. 13. The Reynolds number Re2 closely behind the shock front as a function of the normalized propagation time (tsw is the time, when the shock wave has slowed down to sound wave velocity; see the last section).