Hostname: page-component-74656f9884-rdgjk Total loading time: 0 Render date: 2026-11-08T06:47:24.452Z Has data issue: false hasContentIssue false

In pursuit of damage tolerance in engineering and biological materials

Published online by Cambridge University Press:  15 October 2014

Robert O. Ritchie*
Affiliation:
Department of Materials Science and Engineering, University of California, Berkeley, USA; roritchie@lbl.gov

Abstract

The ability to image and quantify material behavior in real time at nano to near-macro length scales, preferably in three dimensions, is a crucial feature of modern materials science. Here, we examine such an approach to characterize the mechanical properties of three diverse classes of materials: (1) biological materials, principally bone, using both in situ small-/wide-angle x-ray scattering/diffraction to probe nanoscale deformation behavior and x-ray computed microtomography to study microscale damage mechanisms; (2) biomimetic materials, specifically a nacre-like ceramic, where microtomography is used to identify toughening mechanisms; (3) synthetic materials, specifically ceramic textile composites, using in situ microtomography to quantify the salient mechanical damage at ultrahigh temperatures. The mechanistic insights for the understanding of damage evolution and fracture afforded by these techniques are undeniable; as such, they can help provide a basis for the achievement of enhanced damage tolerance in structural materials.

Information

Type
Research Article
Copyright
Copyright © Materials Research Society 2014 
Figure 0

Figure 1. Multiple length scale structure and properties of bone. The structure of bone showing the seven levels of hierarchy with the prevailing toughening mechanisms. At the smallest level, at the scale of the tropocollagen molecules and mineralized collagen fibrils, (intrinsic) toughening (i.e., plasticity) is achieved via the mechanisms of molecular uncoiling and intermolecular sliding of molecules. At coarser levels at the scale of the fibril arrays, microcracking and fibrillar sliding act as plasticity mechanisms and contribute to the intrinsic toughness. At micrometer dimensions, the breaking of sacrificial bonds at the interfaces of fibril arrays contributes to increased energy dissipation, together with crack bridging by collagen fibrils. At the largest length scales in the range of 10s to 100s μm, the primary sources of toughening are extrinsic and result from extensive crack deflection and crack bridging by uncracked ligaments, both mechanisms that are motivated by the occurrence of microcracking and are invariably associated with the osteonal structures.1–4 Adapted with permission from Reference 2.

Figure 1

Figure 2. In situ mechanical testing within the x-ray synchrotron. (a) Schematic illustration of the ultrahigh-temperature tensile testing facility for x-ray computed microtomography (beamline 8.3.2 of the Advanced Light Source).6 The sample, held in water-cooled grips in a vacuum-sealed cell mounted on an air-bearing rotation stage, is heated (b) through a hexapole arrangement of 150 W halogen lamps, each with an ellipsoidal reflector aimed at the center of the cell, giving a spherical hot zone of diameter ∼5 mm. Load is applied by a stepper motor, with force and displacement measured with an in-line load cell and linear variable differential transformer sensor. A 360 degree, 300-μm-thick aluminum x-ray window around the cell supports both the chamber weight and the force on the sample, allowing x-rays to illuminate the sample and pass through to the imaging system. (c) Schematic of the rig in transmission mode for x-ray computed microtomography. (d) SAXS/WAXD testing7 where samples are exposed to high flux x-ray radiation (beamline 7.3.3 of the Advanced Light Source) causing the 67-nm stagger in the mineralized collagen fibril to scatter x-rays at a small angle (SAXS), while the hydroxyapatite mineral’s lattice diffracts x-rays at a high angle (WAXD). As load is applied, changes in the peak positions are used to calculate the individual strains in the mineral and collagen fibrils, with the tissue strain measured with a CCD camera.

Figure 2

Figure 3. Role of aging on the mechanical properties of human cortical bone. (a) Strength and (b) fracture toughness R-curves for bone tested in 25°C Hanks’ Balanced Salt Solution (HBSS) from young (34–41 years old), middle-aged (61–69 years old), and aged (85–99 years old) groups (longitudinal orientation).7 X-ray computed tomographs of the Haversian canal distributions in (c) young and (d) aged bone (color coding indicates canal diameter); (e) aged bone has nearly three times the osteonal density On.Dn., implying more cement lines for microcracks to initiate and smaller crack bridges during crack growth.7In situ uniaxial testing with (f) small- and wide-angle x-ray scattering/diffraction analysis permits partitioning of strain in the collagen and mineral under load. At a fixed tissue strain, the individual strain in the collagen fibrils is ∼25% smaller in aged bone than in young bone; changes in the mineral strain are not significant. (g) The lower strain in the collagen in aged bone is consistent with the accumulation of non-enzymatic AGE collagen cross-links, which act to suppress bone plasticity via fibrillar sliding. All tests involve bone saturated in HBSS. Adapted with permission from Reference 7.

Figure 3

Figure 4. Role of osteogenesis imperfecta (OI) on uniaxial tensile and fracture toughness properties of mouse cortical bone for healthy (wild type [ WT ], red) and mild (oim/+, blue) and severe osteogenesis imperfecta (oim/oim, green).21 (a) Uniaxial tensile tests show significant reductions in both strength and ductility in diseased bone. (b) Similarly, fracture toughness R-curve properties, in terms of the stress intensity K as a function of crack extension Δa, reveal much lower toughness coupled with reduced stable crack growth in oim bones. Crack-initiation toughnesses (where Δa → 0) in oim/+ and oim/oim and bone are, respectively, 30% and 60% of that of healthy bone. (ASTM valid measurements are represented with a continuous line with invalid measurements with a dotted line). Such disease-related deterioration in bone toughness is consistent with (c) the crack paths and (d) fracture modes. Crack paths in WT bone underwent multiple crack deflections, in conjunction with the through-thickness crack twists, resulting in a twofold increase in bone toughness with crack extension-rising R-curve behavior (Figure 1b–c). Crack growth in oim/+ and oim/oim bone, conversely, displayed a much more linear crack path, resulting in an almost flat fracture surface. This is also apparent in the fracture surface morphologies. Rough deflected fracture surface in (WT) bone contrasts the flat fracture surfaces in oim bones. All tests involve bone saturated in Hanks’ Balanced Salt Solution. Adapted with permission from Reference 21.

Figure 4

Figure 5. The hierarchical structure and properties of nacre. (a) Nacre consists of mineral platelets (aragonite) and some proteins arranged in a “brick-and-mortar” structure; the mineral “bricks” provide for strength, with limited slip in the biopolymeric “mortar” allowing for ductility and toughness.32–34 The ∼500 nm thick by ∼5–10 μm wide mineral “bricks” are comprised of millions of nanograins glued together by a biopolymer. If the “bricks” were rigidly interlocked, the resulting structure would be hard yet hopelessly brittle. (b) The “mortar” between the bricks generates limited deformation between the mineral layers, allowing for relief of locally high stresses to provide ductility without loss in strength. Too much “give” in the mortar, however, would result in lower strength. Such interphase displacements are restricted by the mechanisms shown in (b); too hard a mortar, conversely, would result in brick failure. (c) Optimum properties are achieved when the strength of the “mortar” is fractionally less than the strength of the “bricks,” such that toughening via crack bridging can occur when the “bricks” pull out without breaking. (d) This can also be achieved in a synthetic alumina/PMMA material with alumina “brick” pull-out and frictional sliding in the compliant polymeric layer.36 (e) Computed x-ray microtomography of fracture in such “nacre-like” materials shows highly deflected crack paths (in green) and highly non-localized damage in the form of microcracks and interfacial voids (in yellow). (f) Toughness properties of “nacre-like” biomimetic ceramics are compared to those of nacre. The “nacre-like” alumina/PMMA ceramic shows exceptional fracture toughness exceeding Kc > 30 MPa√m, which is an order of magnitude tougher than its constituent phases and homogeneous Al2O3/PMMA nanocomposites.

Figure 5

Figure 6. In situ testing of single-tow SiCf-SiCm composite specimens at room (25°C) and ultrahigh (1750°C) temperatures.38 (a–b) Scanning electron microscope (SEM) micrographs of a room-temperature specimen after testing. Arrows in (a) indicate multiple matrix cracks normal to applied tensile load. Image in (b) was taken after complete separation ex situ. Failure is associated with pull-out of fibers from the matrix. (c) Comparison of image resolution in a reconstructed µ-CT slice from a specimen in (a) before testing and a cross-sectional SEM image from another sample of the same composite. (d) Longitudinal µ-CT slices show (at 127 N) single planar crack at 25°C and bifurcated crack with two fiber breaks (indicated by arrows) at 1750°C. (e) Cross-sectional µ-CT slices from 1750°C specimen (d) at two stages of loading (45 N and 127 N). Red circles indicate fiber that is intact at 45 N and broken at 127 N. (f–g) 3D volume-rendered µ-CT images from specimens tested at 25°C (f) and at 1750°C (g) at several applied tensile loads as indicated (in Newtons). False colors were applied (g) to highlight the different test temperatures (*load reading after first matrix crack initiated).38

Figure 6

Figure 7. Quantification of cracks in matrix and fibers of single-tow SiCf-SiCm composite specimens in Figure 6.38 (a–b) 3D rendering from μ-CT data shows matrix cracks and individual fiber breaks in specimens tested at 25°C and 1750°C at the specific tensile loads (in N) at which they were imaged (*load reading after first matrix crack initiated). The red-blue color scheme indicates the crack-opening displacements (CODs) of matrix cracks, quantified by processing the 3D tomography data. Yellow arrows indicate cylindrical holes remaining after relaxation of broken fibers. The fiber and matrix materials have been set to be transparent to reveal the cracks. (c) Force-displacement curves from in situ tests in (a) and (b). Red curve offset by 70 µm for visual clarity. Hollow circles indicate acquired µ-CT data at that load; blue and red solid circles indicate loads corresponding to images in (a) and (b), respectively. (d) Comparison of statistical data on fiber fracture at peak loads in the specimens in (a) and (b): each symbol indicates the distance of a fiber fracture from the nearest matrix crack, and the separation of the fractured fiber ends after relaxation by sliding; red circles correspond to 1750°C test, black circles to 25°C test. (e) Histograms of the number of broken fibers as a function of distance from the closest matrix cracks at peak load.38