Hostname: page-component-74656f9884-c52kr Total loading time: 0 Render date: 2026-11-09T01:28:21.427Z Has data issue: false hasContentIssue false

Capillary ionic liquid electrospray: beam compositional analysis by orthogonal time-of-flight mass spectrometry

Published online by Cambridge University Press:  05 October 2021

S.W. Miller
Affiliation:
Boston College, Institute for Scientific Research, Chestnut Hill, MA 02467, USA
J.R. Ulibarri-Sanchez
Affiliation:
Universities Space Research Association, Houston, TX 77058, USA
B.D. Prince*
Affiliation:
US Air Force Research Laboratory, Space Vehicles Directorate, Kirtland AFB, NM 87117, USA
R.J. Bemish
Affiliation:
US Air Force Research Laboratory, Space Vehicles Directorate, Kirtland AFB, NM 87117, USA
*
†Email address for correspondence: afrl.rvborgmailbox@us.af.mil

Abstract

Orthogonal time-of-flight mass spectrometry has been used to characterize the kinetic energy and charged species distributions from an in vacuo electrospray ion source for four different ionic liquids at volumetric flow rates between 0.3 and 3.3 nanolitres per second. In all cases, the mass spectra revealed charged species consisting of singly charged and multiply charged ions as well as two broad, unresolved droplet distributions occurring in the 104 to 106 atomic mass unit per charge range. The mean jet velocity and mean jet breakup potential were established from analysis of the energy profile of the high mass-to-charge droplets. At the jet breakup point, we find the energy loss and the jet diameter flow rate dependence of the electrospray beam to be similar to that determined by Gamero-Castaño (Phys. Fluids, vol. 20, 2008, 032103; Phys. Rev. Fluids, vol. 8, 2021, 013701) for 1-ethyl-3-methylimidazolium bis(trifluromethylsulfonyl)imide at similar volumetric flow rates. Similar trends are observed for all four liquids over the flow regime. A jet instability analysis revealed that jet electrification and viscous effects drive the jet breakup from the case of an uncharged, inviscid jet; jet breakup occurs at droplet and jet radius ratios that deviate from 1.89. Using the analytically determined ratio and the beam profile, different species are modelled to reconstruct the mass spectra; primary droplets constitute only a fraction of the total species present. The populations of the species are discussed.

Information

Type
JFM Papers
Creative Commons
To the extent this is a work of the US Government, it is not subject to copyright protection within the United States. Published by Cambridge University Press.
Copyright
© Air Force Research Laboratory, Defense Advanced Research Projects Agency and The Author(s), 2021
Figure 0

Figure 1. TOF instrument used to analyse IL electrospray ion beams in vacuum.

Figure 1

Table 1. Surface tension, density, conductivity, viscosity and dielectric constant of the four ILs used in this study.

Figure 2

Table 2. Characteristic flow rate, current, droplet diameter and velocity for the four ILs in this study.

Figure 3

Figure 2. BMI-DCA mass spectrum for four flow rates. The left (log scale) and right (linear scale) axes use two different intensity scales to illustrate all of the measured ions. All four flow rates have the same intervals on vertical axes.

Figure 4

Figure 3. (a) Contour plot of the mass spectra of EMI-IM at 0.72 nl s−1 (Q/Q0 = 2540) at potentials in the range 300–900 V. The colours are on a log scale, with blue being the most significant intensity. (b) The composite spectrum summed from all data in (a) given as counts vs. m/q. The approximate locations of the various distributions, ions, low m/q and high m/q are given with the solid lines. (c) Slices of (a) at specific potential values, with the ion contributions (<5000 amu q−1) excluded. (d) Intensity of the six smallest mass-to-charge ions plotted against the pulsing plate base potential.

Figure 5

Figure 4. LN fits to high m/q droplet components of BMI-IM at 2.29 nl s−1 for ΔE values incremented by 25 eV q−1. Highlighted are the lowest ΔE value – long dash fit and highest ΔE value – small dash fit.

Figure 6

Figure 5. The m/q centroid, x0, values of the LN fit to the high m/q droplet component for the four ILs at two different flow rates. Note the BMI-DCA IL is represented by circle, EMI-IM is represented by diamonds, BMI-IM is represented by squares and BMI-BF4 is represented by triangles. The lines represent linear fits to the selected data.

Figure 7

Figure 6. Integrated ion peaks and droplet distributions of EMI-IM charged particles that have been scaled to allow for comparison of the relative FWHM and centroid values at two flow rates. The vertical lines mark the centroids of a Gaussian fit to each data set and the arrows indicate the direction of shift with increasing flow rate.

Figure 8

Figure 7. Comparison of the weighted average (WA) of the high m/q distribution to the ratio of the mass flow rate divided by the emitter current (Q/I) for three liquids at selected flow rate values.

Figure 9

Figure 8. Comparison of the emitter output per dimensionless flow rate for the electrosprayed ILs BMI-IM, BMI-BF4, EMI-IM and BMI-DCA using the dimensionless scaling laws of Gañán-Calvo et al. (2018); (a – top) dimensionless current output with the dashed line representing the theoretical prediction; (a – bottom) theoretical prediction of the dimensionless mean droplet diameter. The results overlap for each IL, thus only two are illustrated; (b – top) theoretical and experimental m/q values of the mean droplet shown for three ILs; (b – bottom) theoretical ratio of droplet mean charge to Rayleigh charge limit. The initial emitted mean droplets are expected to be super Rayleigh above Q/Q0 = 2147.

Figure 10

Figure 9. BMI-IM data plotted for potential versus mass-to-charge ratio. The data points represent the high m/q droplet distribution centroids for select flow rates. Note the open symbols represent the singly charged ions n = 0–5 at each flow rate and correspond to the y-intercept potentials, ΦTip.

Figure 11

Table 3. High m/q droplet distribution projected velocity and breakup potential for select flow rates of all four ILs. The errors represent the accuracy of the linear data fit; ΔΦ is the associated potential loss values for the droplets and ions. Ions – singly charged ions of n = 0, 1, 2, etc. aAnion emission data point.

Figure 12

Figure 10. Illustrated electrospray data of the high m/q distribution partly listed in table 3; (a) the potential loss along the cone-jet, ΔΦ; (b) the mean breakup velocity; (c) the dimensionless jet radius, RJet/D0, (filled markers) and dimensionless primary droplet diameter, DD/D0 (open markers); (d) the jet radius normalized with Gañán-Calvo's characteristic radius RG (Gañán-Calvo et al.2018). The additional EMI-IM data from Gamero-Castaño (2008b) and Gamero-Castaño and Cisquella-Serra (2021) are shown for comparison; noted in the legend as GC1 and GC2, respectively. The error bars represent the accuracy of the linear data fit as seen figure 9.

Figure 13

Table 4. Parameters used for the primary droplet estimation. Here, RD is the primary droplet radius associated with the maximum growth rate of the jet perturbation and is equal to DD/2. aAnion emission data point. ILs listed are BMI-DCA – BD, EMI-IM – EI, BMI-IM – BI and BMI-BF4 – BB.

Figure 14

Figure 11. (a) Intensity of selected m/q values as a function of the base plate potential. (b) Statistical outputs of Gaussian fits to the distributions. FWHM values are offset in x by 25 000.

Figure 15

Figure 12. Kinetic energy integrated mass spectrum for EMI-IM and BMI-IM at six flow rates. Dashed line indicates the expected m/qRay value of the primary droplet, the dash-dot line indicates the m/qRay value of the large droplet while the dotted line indicates the m/qRay value of the small droplet.

Figure 16

Table 5. Model 1 analysis results from selected liquids and flow rates for EMI-IM (EI) and BMI-IM (BI). Here, m is given in amu, q is given in integer charges and represents the range in which the middle 80 % of the charge is contained and qRay is the Rayleigh charge of the primary droplet. Pri, primary droplet; Lg, large droplet; and Sm, small droplet.

Supplementary material: File

Miller et al. supplementary material

Miller et al. supplementary material

Download Miller et al. supplementary material(File)
File 1.1 MB