1. Introduction
Knowledge of the throughput (or mass flow rate) of rarefied gas through a long capillary is essential in many fields, including vacuum technology, microfluidics, aerospace research, the miniaturization of technological processes, etc. This is particularly relevant for MEMS (microelectromechanical systems) devices such as micropumps and microvalves used in lab-on-a-chip applications (Ameri et al. Reference Ameri, Imanparast, Passandideh-Fard and Shaegh2022), in gas chromatography analysis (An, Gupta & Gianchandani Reference An, Gupta and Gianchandani2014) and in medical research focused on respiratory airflow and aerosol transport in the lungs (Sznitman Reference Sznitman2022). Furthermore, knowledge about the mass flow rate through microchannels is critical for various technological applications, including the development of coaxial ion sources (Sharipov, Graur & Salançon Reference Sharipov, Graur and Salançon2025), plasma-based acceleration projects at CERN (Caldwell et al. Reference Caldwell2016) and procedures for pressure gauge calibration (Berman Reference Berman1985).
Several methods are available for measuring throughput (or mass flow rate) through a tube, with the constant pressure and constant volume techniques being the most widely used (see Suetin et al. Reference Suetin, Porodnov, Chernyak and Borisov1973; Arkilic, Schmidt & Breuer Reference Arkilic, Schmidt and Breuer1997; Jousten, Menzer & Niepraschk Reference Jousten, Menzer and Niepraschk2002); Maurer et al. (Reference Maurer, Tabeling, Joseph and Willaime2003); Colin, Lalonde & Caen (Reference Colin, Lalonde and Caen2004); Ewart et al. (Reference Ewart, Perrier, Graur and Méolans2006); Berg, Gooding & Vest (Reference Berg, Gooding and Vest2014). The constant pressure method involves measuring changes in volume over time, typically by monitoring the displacement of a piston. However, this approach is difficult to implement for low mass flow rates measurement due to the difficulty of detecting small volume changes caused by the slow movement of the piston. In addition, maintaining a leak-free system over extended periods adds further complexity, (see McCulloh et al. Reference McCulloh, Tilford, Ehrich and Long1987; Jousten et al. Reference Jousten, Messer and Wandrey1993, Reference Jousten, Menzer and Niepraschk2002); Wangkui et al. (Reference Wangkui, Dixin, Qiang, Shiliang, Detian and Yang1996), Peksa et al. (Reference Peksa, Gronych, Vicar, Jerab, Repa, Tesar, Prazak and Krajicek2011); Berg et al. (Reference Berg, Gooding and Vest2014).
In contrast, the constant volume technique is more suitable for measuring small quantities of gas flowing through a capillary and has been extensively employed to measure mass flow rates (Suetin et al. Reference Suetin, Porodnov, Chernyak and Borisov1973; Arkilic et al. Reference Arkilic, Schmidt and Breuer1997; Maurer et al. Reference Maurer, Tabeling, Joseph and Willaime2003; Colin et al. Reference Colin, Lalonde and Caen2004; Ewart et al. Reference Ewart, Perrier, Graur and Méolans2006, Reference Ewart, Perrier, Graur and Méolans2007; Pitakarnnop et al. Reference Pitakarnnop, Varoutis, Valougeorgis, Geoffroy, Baldas and Colin2010; Bhandarkar, Parham & Fair Reference Bhandarkar, Parham and Fair2011; Hadj Nacer et al. Reference Hadj Nacer, Graur, Perrier, Méolans and Wüest2014). This method involves recording pressure variations over time in both reservoirs. By applying the equation of state, and assuming steady state and isothermal conditions, the mass flow rate is determined by fitting the pressure variation over time. To ensure the stationary assumption, the volumes of the inlet and outlet tanks must be large enough in comparison with that of a capillary. Large tank volumes guarantee that the flow parameters are independent of time: although detectible, the mass variations occurring in the tanks during the experiments do not call into question the steady-state assumption. Thus, a limit for the maximal suitable variation of the pressure in the tanks must be set depending on the inlet and outlet conditions. The duration of the measurement interval must also be carefully chosen: it should be short enough to maintain quasistationary conditions in both reservoirs, i.e. so that the variation of any macroscopic quantity inside the tanks remains negligible, but also long enough to allow the pressure changes to be measured with sufficient accuracy.
An improvement of the constant volume technique was proposed in the works of Rojas-Cárdenas et al. (Reference Rojas-Cárdenas, Silva, Ho, Deschamps and Graur2017) and Johansson et al. (Reference Johansson, Testa, Zaier, Perrier, Bonnet, Moulin and Graur2018), where the mass flow rate for different pressure differences between the tanks was obtained with a single measurement, and the limitation of a single experimental run duration was removed. However, to maintain the mean pressure between the tanks quasiconstant during the measurements, either the inlet and outlet tanks volumes must be equal, or the initial pressure drop between the reservoirs must be limited. Maintaining a constant mean pressure allows the pressure variation in each tank to be fitted using an exponential function with a single relaxation time. A further improvement of this technique was proposed by Silva et al. (Reference Silva, Deschamps, Rojas Cárdenas, Barrot-Lattes, Baldas and Colin2018), which removes the constraints on equal reservoir volumes and initial pressure difference. Nevertheless, this refined technique requires an additional assumption, namely, that the tube conductance varies linearly with the mean pressure, to ensure the reliability of the results.
In the present work, we propose a further improvement of the constant-volume technique. This improvement concerns three main aspects: (i) the method enables the recording of a continuous pressure curve over a wide range of values in a single experimental run, allowing the extraction of well-defined Poiseuille coefficients across a broad span of rarefaction parameters without the need for multiple experiments; (ii) the one-tank set-up makes it possible to evaluate the influence of small gas leaks (or outgassing) and to incorporate the corresponding correction into the Poiseuille coefficient calculations; (iii) unlike the classical two-tank approach, the one-tank technique does not require the inlet and outlet reservoir volumes to be nearly identical. Additionally, a new experimental methodology is proposed, based on the further development of the constant volume method (Sharipov & Graur Reference Sharipov and Graur2025). This approach allows the more reliable determination of the values of the Poiseuille coefficient, especially in the transitional flow regime. The paper is organized as follows: first, the experimental set-up and measurement technique are presented, followed by an explanation of the theoretical background. Finally, experimental results on the time dependent pressure variation, the Poiseuille coefficient and the velocity slip coefficient are presented and compared with available numerical predictions.
2. Experimental set-up
The constant-volume technique is used to measure the properties of gas flow through a microchannel, which is fixed between inlet and outlet tanks. The experimental set-up scheme is shown in figure 1. The volumes of the inlet and outlet tanks, including the volumes of the valves and connecting tubes, are equal to
$(29.6\pm 1.42)$
cm
$^3$
and
$(22.6\pm 1.08)$
cm
$^3$
, respectively. The reference volume was determined gravimetrically by weighing it before and after filling it with deionized water. The temperature of the water was recorded, and its density calculated accordingly, allowing the volume to be determined from the measured mass. The volumes of the inlet and outlet tanks were then derived using the reference volume and Boyle’s law. The pressure variations in both tanks are measured using three different capacitance diaphragm gauges (CDG) with full-scale ranges of 10, 100 and 1000 Torr, selected based on the chosen initial pressure. Since each sensor has a different internal volume (3.6, 4.2 and 4.2 cm
$^3$
, respectively, as specified by manufacturer), these volumes are added to the total volume of each tank. Finally, the total inlet volume (
$V_{\textit{in}}$
) became 33.2, 33.8 and 33.8 cm
$^3$
, respectively, depending on the used sensor. Similarly, the total outlet volume (
$V_{\textit{out}}$
) became 26.2, 26.8 and 26.8 cm
$^3$
, respectively.
Experimental set-up: turbomolecular pump, rotary valve pump, CDG.

The experimental system is located in a room with a quasiconstant temperature. The external temperature of both tanks is measured by thermocouples, so that the temperature variation during each experimental run does not exceed 0.2
$^\circ$
C. Therefore, the gas flow from the inlet to the outlet tank can be considered to be isothermal.
The stainless-steel tube, with a circular cross-section, was positioned between the tanks. This tube was previously used for measurements of the CO
$_2$
mass flow rate by Hadj Nacer et al. (Reference Hadj Nacer, Graur, Perrier, Méolans and Wüest2014), and its diameter was determined using an electronic microscope
$2a=(239.73 \pm 2.40)$
μm, where
$a$
is the tube radius. In the present work, the tube radius was re-evaluated through measurements of the flow rate in the viscous regime, see § 6.2. The tube length is equal to
$L=10.33\pm 0.05$
cm.
3. Measurement procedure and leak estimations
A series of measurements was conducted to cover a wide range of gas flow regimes, from the viscous to free molecular regime (Jousten Reference Jousten2008; Sharipov Reference Sharipov2016). To measure the quantity of gas flowing through the capillary, the following procedure was adopted. First, the system was pumped down for an extended period, typically 24 hr. Then, the inlet tank was filled with the test gas at the desired initial pressure. Valves B, D and E, shown in figure 1, were then closed, allowing the gas to flow through the tube into the outlet tank, which was continuously evacuated. Pressure measurements were performed using two CDG sensors in the inlet tank – 1000 and 100 Torr, depending on the desired pressure – and a 10 Torr sensor in the outlet tank. The inlet tank pressure varies from
$15.91$
to
$2.13$
kPa. The typical duration of these measurements ranged between 5 and 15 min. Under these conditions, measurements in the viscous and slip flow regimes were conducted.
To reach the transitional and early free molecular flow regimes, measurements were performed using 10 Torr sensors for both the inlet and outlet tanks. Long-duration measurements (around 10 hr) revealed the presence of minor leaks in the inlet tanks. To characterize and quantify the dynamics of these leaks, the system was first evacuated by opening valves A, B and C (see figure 1). To measure specifically the leaks in inlet tank, valve A was closed while valves B and C remained open. However, this procedure did not yield reproducible measurements, limiting its effectiveness for consistent leak characterization. Finally, for each low-pressure measurement, the leak rate is analysed and the measured pressure is corrected, see § 6.3 for more details.
4. Modelling
4.1. Main definitions
The mass flow rate,
$\dot M$
[kg s
$^{-1}$
], through a tube connecting two tanks can be related to the pressure variation in both tanks. As shown in Sharipov & Graur (Reference Sharipov and Graur2014), the mass flow rates are the same in the capillary inlet and outlet when the capillary volume is significantly smaller than that of the tanks. The volume of the tube used in the set-up, is
$4.7\times10^{-3}$
cm
$^3$
, that is much smaller than the tank volume. Therefore, the mass flow rate can be related to the inlet pressure variation as
where
$T$
is the gas temperature,
${\mathcal R}_g=8.314$
J K
$^{-1}\,$
mol
$^{-1}$
is the universal gas constant,
$\mathcal M$
is the gas molar mass,
$p_{\textit{in}}$
is the pressure in the inlet reservoir,
$t$
is the time. This expression is derived under several assumptions: (i) the ideal gas law is valid; (ii) the volume
$V_{\textit{in}}$
remains constant; (iii) the gas flow is isothermal. To quantify the deviation from ideal gas law conditions, the compressibility factor
$Z=pV{\mathcal M}/(M{\mathcal R}_g T)$
is usually introduced (Reid, Prausnitz & Poling Reference Reid, Prausnitz and Poling1987). Using the CoolProp library (Bell et al. Reference Bell, Wronski, Quoilin and Lemort2014) with the specified pressure and temperature values, the compressibility factor
$Z$
was calculated. In all cases, the relative deviation of
$Z$
from unity was smaller than 0.0001
$\,\%$
, indicating that non-ideal gas effects are negligible, so the first assumption is valid. The second assumption is also fulfilled for the used set-up. The influence of the temperature variation is estimated via the quantity
$\varepsilon =(\Delta T/T)/(\Delta p/p)$
. During the experiments, the maximum temperature variation is approximately 0.3
$^{\circ }$
C, leading to
$\Delta T/T\sim 10^{-3}$
, while the pressure variation is large, i.e.
$\Delta p/p \sim 1$
. Therefore,
$\varepsilon$
is of the order of
$10^{-3}$
, hence, the temperature variation can be neglected. Thus, the expression (4.1) is applicable to measuring the mass flow rate in the whole range of the pressure considered in the present work.
Theoretical results on the mass flow rate are, usually, reported in term of the Poiseuille coefficient
$G_{\kern-1pt p}$
(Sharipov Reference Sharipov2016). For a long tube (
$a\ll L$
), the mass flow rate is related to the Poiseuille coefficient
$G_{\kern-1pt p}$
as described in Sharipov & Seleznev (Reference Sharipov and Seleznev1994) and Sharipov (Reference Sharipov1997),
where
$v{_{{m}}}$
is the most probable molecular speed, defined as
where
$p$
is the local gas pressure,
$x$
is a coordinate along the tube, so
$\mbox{d} p/\mbox{d} x$
is a local pressure gradient. The Poiseuille coefficient
$G_{\kern-1pt p}(\delta )$
depends on the local rarefaction parameter
$\delta$
defined as
where
$\ell$
is the equivalent molecular free path. Considering the maximum pressure levels used in the experiments, the gas viscosity
$\mu$
is assumed to depend solely on temperature (Ferziger & Kaper Reference Ferziger and Kaper1972; Shan et al. Reference Shan, Li, Tang, Torrilhon, Zhang and Guo2025) and is calculated from
where
$\mu _{\textit{ref}}$
is the gas viscosity at the reference temperature
$T_{\textit{ref}}$
and
$\omega$
is the viscosity index. According to Sharipov (Reference Sharipov2024), the viscosity index
$\omega$
is variable. However, when the temperature variation is small compared with the reference temperature
$T_{\textit{ref}}$
, which is the case of our experimental conditions, (4.5) holds. The dependence of the viscosity on the gas density is characterized by the viscosity virial coefficient. According to Berg & Burton (Reference Berg and Burton2013), the relative effect of the density on viscosity does not exceed
$10^{-5}$
under the experiment conditions. The values of
$\mu _{\textit{ref}}$
and
$\omega$
based on ab initio calculations, (Sharipov & Benites Reference Sharipov and Benites2019, Reference Sharipov and Benites2021) and empirical representations (Cole & Wakeham Reference Cole and Wakeham1985; Kadoya, Matsunaga & Nagashima Reference Kadoya, Matsunaga and Nagashima1985), are given in table 1, together with the molar mass (Meija et al. Reference Meija2016).
Molar mass
$\mathcal M$
(Meija et al. Reference Meija2016), viscosities
$\mu _{\textit{ref}}$
at the reference temperature
$T_{\textit{ref}}=300$
K and viscosity index
$\omega$
based on the data reported in Sharipov & Benites (Reference Sharipov and Benites2019, Reference Sharipov and Benites2021), Cole & Wakeham (Reference Cole and Wakeham1985), and Kadoya et al. (Reference Kadoya, Matsunaga and Nagashima1985).

By integrating (4.2) along the tube and using the mass conservation one obtains
A combination of (4.1) and (4.6) leads to
where
$\tau$
is the characteristic time of the variation of
$p_{\textit{in}}$
:
Therefore,(4.7) serves as the basic relation for extracting the Poiseuille coefficient from the inlet pressure variation.
4.2. Theoretical data on the Poiseuille coefficient
The Poiseuille coefficient for a long tube has been a subject of extensive study in recent decades (Sharipov & Seleznev Reference Sharipov and Seleznev1998). Here, an assess of the numerical uncertainty of
$G_{\kern-1pt p}$
is given.
Relative difference
$\Delta G_{\kern-1pt p}$
versus rarefaction parameter
$\delta$
: blue line, between S-model and Bhatnagar–Gross–Krook (BGK) model
$\Delta G_{\kern-1pt p}=(G_{\kern-1pt p}^{S}/G_{\kern-1pt p}^{\textit{BGK}}-1)\boldsymbol{\cdot }100\,\%$
; red symbols, between S-model and LBE
$\Delta G_{\kern-1pt p}=(G_{\kern-1pt p}^{S}/G_{\kern-1pt p}^{\textit{LBE}}-1)\times100\,\%$
; black line, relative error of approximation (5.1).

The Poiseuille coefficient was obtained in Cercignani & Sernagiotto (Reference Cercignani and Sernagiotto1966) applying the BGK model (Bhatnagar, Gross & Krook Reference Bhatnagar, Gross and Krook1954). The same data based on the S-model (Shakhov Reference Shakhov1968) are reported in Sharipov (Reference Sharipov1996). The linearized Boltzmann equation (LBE) with the hard sphere potential was solved to calculate
$G_{\kern-1pt p}$
for a tube in Wu et al. (Reference Wu, Zhang, Liu, Zhang and Reese2017). The relative differences of the results based on the BGK model and LBE from those based on the S-model are plotted in figure 2, which shows that the maximum discrepancy of 2 % between these results is observed in the transitional regime (
$\delta =1$
). In the limits
$\delta \to 0$
and
$\delta \to \infty$
, the discrepancy vanishes. Theoretical data on
$G_{\kern-1pt p}$
for tube based on ab initio or Lennard–Jones potential are not available. In order to assess the influence of the potential, the data on the orifice flow by Sharipov & Strapasson (Reference Sharipov and Strapasson2014) at a small pressure drop can be used. These results point out that the flow rate based on ab initio potential is just slightly larger than that based on the hard sphere potential. The deviation does not exceed 1.4 %, i.e. the real Poiseuille coefficient should be between the values obtained from the S-model and those obtained from LBE for the hard sphere potential. Therefore, the red symbols in figure 2 indicate the theoretical uncertainty of the Poiseuille coefficient for the tube flow.
5. Extraction of the Poiseuille coefficient
5.1. Main methods
The relation (4.7) allows us to express the rate of the pressure variation via the average Poiseuille coefficient in the pressure range from
$p_{out}$
to
$p_{in}$
. However, it is not trivial to express
$G_{\kern-1pt p}$
at a specific value of the rarefaction
$\delta$
via the pressure derivative.
The usual approach to this problem is to approximate the integral on the right-hand side of (4.7) as (Sharipov & Seleznev Reference Sharipov and Seleznev1994)
where the rarefaction parameter
$\delta _m$
is calculated from (4.4) using the mean pressure
$p_m=(p_{in}+p_{out})/2$
. The error of this approximation is plotted in figure 2 by the black line, which shows that it reaches its maximum of 1.5 % at
$\delta _m=2$
. Then it vanishes in both limits
$\delta \to 0$
and
$\delta \to \infty$
. Assuming that
$p_{out}\ll p_{in}$
, a combination of (4.7) and (5.1) leads to
Another approach (Sharipov & Graur (Reference Sharipov and Graur2025) is based on the assumption that the outlet pressure
$p_{\textit{out}}$
remains constant during the measurement period. This condition can be met either if the outlet reservoir volume is significantly larger than the inlet volume, or if the outlet reservoir is continuously pumped down to maintain a constant pressure. First, we calculate the derivative of both sides of (4.7) which leads to
Then, the term with a derivative in time of the outlet pressure,
$\mbox{d} p_{\textit{out}}/\mbox{d} t$
, is neglected under condition of constancy of the outlet pressure. Therefore, the expression of the Poiseuille coefficient is obtained as a function of the inlet pressure derivatives and the characteristic time
The advantage of this method is that it does not rely on any approximation. However, it requires to calculate the second derivative that is not easy, when the pressure
$p_{in}$
is given as a table of measurement data.
5.2. Viscous and slip regime
In the case of viscous flow regime the Poiseuille coefficient is equal to
In this case, (5.2) is easily integrated and the evolution of the inlet pressure with respect to the time is obtained as
where
Here
$\delta _{\textit{in0}}$
is the rarefaction parameter, (4.4), calculated with initial inlet pressure
$p_{\textit{in0}}$
at
$t=0$
.
In the case of the slip flow regime (
$\delta _{\textit{in}}\gt 10$
), the Poiseuille coefficient is obtained analytically as in Sharipov (Reference Sharipov2016),
where
$\sigma_{\kern-1pt p}$
is the slip coefficient (Sharipov Reference Sharipov2011). Then, (5.2) becomes
By integrating (5.9) with respect to the time, the evolutions of the pressure
$p_{\textit{in}}$
is obtained as
where
and
These expressions can be used to extract the tube radius
$a$
and the velocity slip coefficient
$\sigma_{\kern-1pt p}$
from the experimental data on
$p_{\textit{in}}$
for large values of the rarefaction parameter. In this case, the quantities
$B$
and
$c$
are used as fitting parameters.
The experimental value of the relaxation time,
$\tau ^{\textit{exp}}$
, is defined from the fit in the viscous regime as
In § 6, the theoretical value of the relaxation time given by (4.8) is compared with the experimental one, (5.13). Additionally, when the relaxation time is normalized by the characteristic time defined as
$t{^{{ch}}}=L/v{_{{m}}}$
it becomes to be independent from the gas nature.
Finally, the Poiseuille coefficient in the slip flow regime is extracted from (5.2). The pressure variation in the inlet tank is recorded and fitted using the form given in (5.10), with
$B$
and
$c$
as fitting parameters. The time derivative of the pressure is then calculated analytically with these fitted parameters and
$G_{\kern-1pt p}$
is calculated from (5.2). The results are presented in § 6.
5.3. Transitional regime
To extract the Poiseuille coefficient from (5.2) and (5.4) we need to calculate the first and second derivatives of the measured pressure with respect to time. To calculate them, the measured pressure is locally represented around a point
$t_i$
, within the interval
$[t_i-\Delta t, t_i+\Delta t]$
, by means of a nonlinear regression of the form
\begin{align} p_{\textit{in}}(t)=C_0\exp \left (\sum _{n=1}^4 C_n(t-t_i)^n\right )\!, \end{align}
where
$C_n$
(
${1}\le n\le 4$
) are coefficients to estimate, obtained by the least square method. Then, the first and second derivatives read
When, the approximation (5.1) is used, (5.15) is substituted into (5.2) and the Poiseuille coefficient is calculated by the first method as
Substituting (5.15) and (5.16) into (5.4), the coefficient
$G_{\kern-1pt p}$
is calculated by the second method as
where the rarefaction parameter
$\delta {_{{i}}}$
is calculated via (4.4) using
$C_0$
for pressure
$p_{\textit{in}}(t{_{{i}}})$
.
Finally, expression (5.18) is more correct from theoretical point of view because allows to obtain the expression for the Poiseuille coefficient directly from (4.7) without any additional approximation, required for derivation of (5.17). In § 6, two expressions will be used to extract the Poiseuille coefficient values from the pressure measurements.
5.4. Experimental uncertainty
The experimental uncertainties associated with the measurements performed using the set-up arise from the inlet volume (
$u_V$
), tube radius (
$u_a$
), tube length (
$u_L$
), time (
$u_t$
), gas temperature (
$u_T$
) and gas pressure (
$u_p$
). All these uncertainties are summarized in table 2. The uncertainty of the pressure sensors (
$u_p$
) depends on their measurement range. For the 10 Torr sensor,
\begin{align} u_p=\left \{ \begin{array}{ccc} 0.50\,\% & \mbox{at} & 0.1\le p \le 0.25,\\ 0.25\,\% & \mbox{at} & 0.25\le p \le 1,\\ 0.20\,\% & \mbox{at} & 1\le p \le 10,\\ \end{array}\right . \end{align}
where
$p$
is in Torr. The 100 and 1000 Torr sensors have the maximum error of 0.15 % of the reading, according to the manufacturer. There is no information on the minimum detectable pressure for the sensors. However, for 10 Torr sensors the oscillations occur for reading pressure below 30 Pa for lighter gases and below 10 Pa, for the heavier ones. When the amplitude of the oscillations becomes a half of the measured values, the measurement is discarded. Table 2 contains the highest uncertainty
$u_p$
, which is 0.50 %.
Uncertainties (%) of the main measured parameters.

The mass flow rate and Poiseuille coefficient are determined using the fitting of the measured pressure data. To evaluate the fit quality, standard statistical parameters are used, including the coefficient of determination, the sum of squared residuals and the standard error (
$E{_{{s}}}$
). Only the standard error is taken into account for the uncertainty estimation, and its highest value is reported in table 2.
The combined standard uncertainties
$u$
were calculated following the standard procedure (GUM 2008) as
$u=\sqrt {\sum _i u_i^2}$
. The uncertainty of the mass flow rate
$\dot M$
contains
$u_V$
,
$u_t$
,
$u_T$
and
$u_p$
, so that
$u=4.3\,\%$
. The Poiseuille coefficient uncertainty includes all those given in table 2 and equal to
$u=5.2\,\%$
.
The uncertainty of
$\tau$
is
According to (5.17) and (5.18), this is the main uncertainty of
$G_{\kern-1pt p}$
besides that of
$C_1$
and
$C_2$
.
6. Results
The pressure variation over time due to gas flow through a microtube was measured for six gases: He, Ne, Ar, N
$_2$
, Kr and Xe. Different pressure ranges were studied, and the results are regrouped into two parts: (i) viscous and slip flow regimes; (ii) transitional and free molecular regimes. The link to the row data for all gases in these two ranges can be found in Appendix B (Supplementary material).
6.1. Viscous and slip flow regimes
A series of measurements was conducted in the viscous and slip flow regimes. Typical inlet pressure variation over time, normalized by the initial pressure,
$p_{\textit{in0}}$
, for each gas is shown in figure 3(a), the corresponding rarefaction parameter is plotted in figure 3(b). This measured pressure variation is fitted using expression (5.10). Table 3 summarizes the values of the fitting coefficients
$B^{\textit{fit}}$
and
$c^{\textit{fit}}$
, obtained for typical experimental runs with different gases.
(a) Measured inlet pressure
$p_{\textit{in}}/p_{\textit{in0}}$
versus time; (b) rarefaction parameter
$\delta {_{{m}}}$
versus time.

Fitting coefficients,
$B^{\textit{fit}}$
and
$c^{\textit{fit}}$
, of the pressure variation over time according to (5.10), for the slip flow regime. For each gas the initial pressure as well as the mean temperature of each run are provided. The standard error,
$E{_{{s}}}$
, of the fitted parameter was estimated using the residual variance and the sensitivity of the model, following the classical approach described in Seber & Wild (Reference Seber and Wild1989). Standard error allows to calculate the length of the confidential interval
$y_{\textit{mean}}\pm 1.95 E{_{{s}}}$
,
$y_{\textit{mean}}$
is the mean value of measured quantity.

Poiseuille coefficient
$G_{\kern-1pt p}$
for all tested gases versus the rarefaction parameter
$\delta {_{{m}}}$
. The experimental values of
$G_{\kern-1pt p}$
are obtained from (5.2) in combination with (5.10), while the numerical values are calculated from (A1). The error bars shown for
$G_{\kern-1pt p}$
indicate an uncertainty of 5.2
$\,\%$
relative to the corresponding Poiseuille coefficient value. The error bars on the rarefaction parameter are not presented on the figures to avoid clutter.

Figure 4 shows the Poiseuille coefficient for all gases as a function of the rarefaction parameter, calculated using the mean pressure,
$\delta {_{{m}}}$
. The experimental values of
$G_{\kern-1pt p}$
are obtained from (5.2) in combination with (5.10), while the numerical values are calculated from (A1). This latter expression represents a fit to the numerical solution of the S-model kinetic equation, obtained under the assumption of complete accommodation of gas molecules at the surface. A good agreement is observed between the experimental and numerical results, within the bounds of experimental uncertainty.
6.2. Estimation of several key parameters from the pressure measurements
As shown in the previous section, the pressure variation over time in the slip flow regime is accurately described by the analytical expression (5.10). Two fitting parameters,
$B$
and
$c$
, are linked to seven physical quantities: the channel radius
$a$
; the channel length
$L$
; the inlet reservoir volume
$V_{{in}}$
; the gas viscosity
$\mu$
; the most probable molecular speed
$v_{{m}}$
(the last two depending on the gas type and its temperature); the initial pressure
$p_{{in0}}$
; the velocity slip coefficient
$\sigma _{{p}}$
. Among these, all can be directly measured (or, in the case of viscosity, calculated) except for one: the velocity slip coefficient. Since we have two fitting parameters,
$B$
and
$c$
, describing the pressure variation over time, we can determine the values of two quantities of interest from the list of seven. Here, we derive the channel radius and the velocity slip coefficient from following expressions:
\begin{align} \sigma_{\kern-1pt p}^{\textit{fit}}=\frac {1}{4 v{_{{m}}}}\left (\frac {c^{\textit{fit}}L V_{\textit{in}} p_{\textit{in0}}^3}{\pi (B^{\textit{fit}}\mu )^3}\right )^{1/4}\!, \\[2pt] \nonumber \end{align}
using the fitting coefficients. Both values,
$a^{\textit{fit}}$
and
$\sigma_{\kern-1pt p}^{\textit{fit}}$
, are reported in table 4 for all the gases tested. As can be seen, the tube radius values are determined with an accuracy of approximately 1.5 μm, which is comparable to the accuracy achieved using an electron microscope (around 1–2 μm). In addition, the average radius across all gases is 119.65 μm, which is very close to the value obtained from electron microscopy, namely 119.87 μm. This latter value is used in the following analysis.
The values of tube radius,
$a^{\textit{fit}}$
, and the velocity slop coefficient,
$\sigma_{\kern-1pt p}{^{{{fit}}}}$
, obtained from the fit of measured pressure variation over time (5.10). Here
$\sigma_{\kern-1pt p}^*$
is the velocity slip coefficient calculated from (6.3) with the value of tube radius obtained from the electron microscope,
$\sigma_{\kern-1pt p}^{**}$
is the velocity slip coefficient obtained from polynomial fit of normalized Poiseuille coefficient (6.4),
$\sigma_{\kern-1pt p}^{AI}$
is derived by Basdanis et al. (Reference Basdanis, Valougeorgis and Sharipov2023) using ab initio potential.

As shown in table 4, the tube radius obtained using the proposed technique exhibits slight variations across different gases, which is not physically realistic. Therefore, the tube radius is fixed to the value measured with the electron microscope, and the velocity slip coefficient is then calculated based on this fixed radius using the following expression:
\begin{align} \sigma_{\kern-1pt p}=\frac {1}{2a v{_{{m}}}}\sqrt {\frac {c^{\textit{fit}}}{B^{\textit{fit}}}\frac {p_{\textit{in0}} L V_{\textit{in}}}{\pi \mu }}. \end{align}
The values of the velocity slip coefficient, calculated from (6.3), are provided in table 4, denoted
$\sigma_{\kern-1pt p}^*$
.
Previously different authors (Porodnov et al. Reference Porodnov, Suetin, Borisov and Akinshin1974); Maurer et al. Reference Maurer, Tabeling, Joseph and Willaime2003); Colin et al. Reference Colin, Lalonde and Caen2004); Ewart et al. Reference Ewart, Perrier, Graur and Méolans2007) derived the velocity slip coefficient from the Poiseuille coefficient. Indeed, (5.8) can be written in following form:
By fitting expression
$S-1$
with a first-order polynomial in
$1/\delta$
as
$S-1=a_0+a_1/\delta$
, the velocity slip coefficient is then determined as
$\sigma_{\kern-1pt p}=a_1/4$
. These values of the velocity slip coefficient, calculated from (6.4), are provided in table 4, denoted
$\sigma_{\kern-1pt p}^{**}$
. It is worth to noting that, from a theoretical point of view,
$a_0$
should to be equal to zero. Therefore, its deviation from zero can serve as an indicator of the fit quality. The errors observed in the
$\sigma_{\kern-1pt p}^{**}$
values (table 4) indicate that the uncertainty associated with this method is higher.
A comparison between the values of the velocity slip coefficient obtained from the two different methods, i.e.
$\sigma_{\kern-1pt p}^{*}$
and
$\sigma_{\kern-1pt p}^{**}$
, shows very good agreement, with a maximum deviation of 4
$\,\%$
observed for krypton.
The values of the slip coefficient obtained using the ab initio potential and assuming diffuse gas–surface interaction (Basdanis, Valougeorgis & Sharipov Reference Basdanis, Valougeorgis and Sharipov2023) are also presented in the same table. As the data analysis shows, the difference between the measured values of
$\sigma_{\kern-1pt p}$
and those calculated is significant for argon and krypton. This large deviation can be attributed to the pressure measurement range (see figure 3); that is, the corresponding rarefaction parameter values for these two gases are closer to the viscous flow regime than to the slip regime.
Another parameter of interest, the relaxation time
$\tau$
, can also be extracted by fitting the pressure variation over time in viscous flow regime using (5.6) and then (5.13). Analysing the analytical expression for the relaxation time (4.8), it is clear that
$\tau$
, when normalized by the time,
$t{^{{ch}}}=L/v{_{{m}}}$
, should remain constant whatever is a gas. This property can thus serve as a criterion for assessing the quality of the measurements. The measured characteristic times, obtained from (5.13), are provided in table 5 along with the corresponding theoretical values from (4.8). As can be seen from these data, the measured characteristic times systematically lower than the theoretical values for all analysed gases, with the discrepancy being significantly greater (around 10
$\,\%$
) for helium and neon. This difference can be attributed to the measurement range for these gases, which lies more in the slip regime than in the viscous regime. The measured characteristic time normalized by
$t{^{{ch}}}$
is given in the third row of table 5. The deviation from the theoretically calculated value,
$\tau /t{^{{ch}}}=1.249\times10^7$
, follows the global trend, i.e. this deviation is is more pronounced for helium and neon.
The measured and theoretical values of the characteristic time for various gases. The measured characteristic time normalized by the time,
$t{^{{ch}}}$
, is given in the third row.

The analytical formulae derived for the viscous and slip flow regimes, (5.6) and (5.10), provide a powerful tool for extracting various parameters, such as the tube dimensions, reservoir volume (not shown in the preset text) or the characteristic time. However, the applicability of each expression is limited to its corresponding flow regime. Therefore, the appropriate regime (viscous or slip) should be respected to ensure accurate data extraction.
It is worth emphasizing that the analytical formulae derived for the viscous and slip flow regimes, (5.6) and (5.10), are obtained considering the monoatomic gas approach. However, in the case of the isothermal flow this approach could be successfully extended to the diatomic and polyatomic gases. The formal comparison between BGK model derived for the monoatomic gases (Bhatnagar et al. Reference Bhatnagar, Gross and Krook1954) and that of Rykov (Rykov Reference Rykov1975) and Holway (Holway Reference Holway1966) models obtained for the diatomic and polyatomic gases, respectively, can be found in Sharipov & Seleznev (Reference Sharipov and Seleznev1998), Titarev & Shakhov Reference Titarev and Shakhov2012), Tantos, Varoutis & Day Reference Tantos, Varoutis and Day2020) and Tantos et al. Reference Tantos, Kritikos, Varoutis and Day2023).
6.3. Transitional and free molecular flow regimes
To reach the transitional and free molecular flow regimes of the gas through the microtube, the inlet reservoir is filled with a test gas to a pressure of approximately 1.3 kPa. The gas then flows through the microtube as it is pumped from the outlet reservoir, see § 3 for details of the measurement procedure. The resulting pressure variation over time is shown in figure 5. For all the tested gases except helium and neon, the inlet pressure begins to stagnate when it decreases to around 7–8 Pa, and then slowly approaches its asymptotic value, which lies between 4 and 7 Pa depending on the gas. In contrast, for helium and neon, the pressure initially decreases, then increases slightly, and finally stabilizes at a quasiconstant value of approximately 4 Pa. This pressure behaviour is attributed to leaks (and/or outgassing) in the inlet reservoir. Several tests were conducted to evaluate their magnitude (see § 3), and the procedure described below was adopted for leak estimation.
Inlet pressure versus time and leak estimation: blue lines, measured pressure; green lines, the fitting curve of possible leak; red lines, corrected pressure.

As seen in figure 5, the pressure curve begins to deviate from a straight, decreasing trend at around 50 Pa. This deviation is caused by an additional throughput that alters the balance between the gas removal rate and the influx rate, as previously noted by Helleret (Reference Helleret1999). As a result, the pressure in the tank stagnates. This pressure evolution in the inlet tank, attributed to leaks (and/or outgassing), is modelled by fitting the data using the following expression, inspired by Helleret (Reference Helleret1999):
where
$p_{\textit{leaks}}(t)$
is the pressure in the inlet tank due to the leaks,
$p_{\textit{in}}(t_{\kern-2pt f})$
is the final measured value of pressure in the inlet tank when
$t\to t_{\kern-2pt f}$
, where
$t_{\kern-2pt f}$
is the final time of an experimental run, and
$\tau _{\textit{leaks}}$
is the leakage relaxation time. The fitting process begins at a specific time,
$t_{\textit{leaks}}$
, identified as the moment when the pressure ceases to decrease and begins to stagnate. This fitting process is realized for each measurement at low pressure. The pressure increases due to leaks, fitted using (6.5), is also shown in figure 5 as a green line. It is evident that the leak-induced pressure rise is well captured by the proposed expression. Once the leak contribution is evaluated, the measured inlet pressure is corrected by subtracting the pressure increase due to the leaks as follows:
Since this pressure contribution is typically very small, this correction is only significant for low-pressure measurements, specifically in the 1–50 Pa range. The corrected experimental pressure,
$p_{\textit{in}}^{\textit{corr}}(t)$
, calculated from (6.6), is shown in figure 5 by the red lines. From figure 5, it is evident that the corrected inlet pressure has an expected behaviour of constant decreasing over time.
The measured data cover several flow regimes, ranging from the slip regime to free molecular flow, passing through the transitional regime. As there are not any analytical expression for pressure in the transitional flow regime, the pressure is fitted using (5.10) derived for the slip flow regime. The fitting coefficients and the corresponding errors are provided in table 6. Even if these coefficients cannot be related to any physical quantities as it was done in the case of the slip flow regime, we can use these coefficients to calculate the
$G_{\kern-1pt p}$
by combining (5.2) and (5.10). The Poiseuille coefficient calculated by this way is shown in figure 6.
The fitting coefficients for all gases for the low-pressure experiments, i.e. the transitional and beginning of free molecular flow regimes. Standard error,
$E{_{{s}}}$
, (Seber & Wild Reference Seber and Wild1989) allows us to calculate the confidence interval; CI is the 95 % confidence interval.

The Poiseuille coefficient can also be extracted using two other approaches, explained in § 5.3, (5.17) and (5.18). The use of both expressions requires the interpolation of the pressure over time in (5.14). Two time steps are tested to calculate the pressure derivatives, namely
$\Delta t=t{_{{i}}}/3$
and
$t{_{{i}}}/6$
, making sure that they lead to the same results. Finally,
$\Delta t=t{_{{i}}}/3$
is used for all calculations. Among two expressions (5.17) and (5.18), the second one does not required any additional approximations as (5.1) to calculate the Poiseuille coefficient
$G_{\kern-1pt p}$
from the measured pressure.
The Poiseuille coefficient extracted from the pressure measurements by three different ways explained above as well as the numerical values obtained from the numerical solution of the S-model kinetic equation, (A1), and the LBE, (A2), are shown in figure 6. Very good agreement is observed between the data sets up to rarefaction parameter values of
$\delta =0.1$
. However, for helium the measured
$G_{\kern-1pt p}$
values begin to deviate from the numerical ones at relatively large values of the rarefaction parameter. This deviation can be attributed to the quality of the pressure fit using (5.10), which performs well in the slip regime, but is probably less accurate in the transitional and free molecular regimes.
The Poiseuille coefficient versus the rarefaction parameter
$\delta {_{{m}}}$
. In each graph: the solid orange line corresponds to (A2), the numerical results obtained from the solution of the LBE; the solid black line corresponds to (A1), the numerical solution of the S-model kinetic equation; blue symbols correspond to the
$G_{\kern-1pt p}$
extraction using (5.2) and (5.10); the red symbols correspond to (5.17); the green symbols correspond to (5.18). The error bars shown for
$G_{\kern-1pt p}$
indicate an uncertainty of 5.2
$\,\%$
relative to the corresponding Poiseuille coefficient value. The error bars on the rarefaction parameter are not presented on the figures to avoid clutter.

The Poiseuille coefficient versus the rarefaction parameter
$\delta {_{{m}}}$
. In each graph: the solid red line corresponds to (A1); the solid cyan line corresponds to the results from Tison (Reference Tison1993); the green circles are the data from Perrier et al. (Reference Perrier, Graur, Ewart and Méolans2011); the orange circles are the data from Hadj Nacer et al. (Reference Hadj Nacer, Graur, Perrier, Méolans and Wüest2014); the black circles are the data from Marino (Reference Marino2009); the blue circles are the present results.

The comparison of the present results with other previously obtained results on the
$G_{\kern-1pt p}$
coefficient are presented on figure 7. As can be seen from the figure, the results presented here are closer to the kinetic theory results.
To sum up, the proposed methodology for the Poiseuille coefficient measurement allows to obtain experimentally the data in very large range of the rarefaction parameter with relatively good accuracy. All approaches confirm the diffuse gas–surface interaction for all tested gases.
7. Conclusion
The new analytical expression of pressure variation over time in the inlet reservoir in the hydrodynamical and slip flow regimes is obtained under assumption of smallness of the outlet pressure compared with the inlet ones. This analytical expression fits extremely well the measured pressure data. From two fitting parameters two key quantities are extracted, the tube radius and the velocity slip coefficient. The average over all gases the tube radius extracted in this way is very close (the difference is less than 1 μm) to that obtained with the electron microscope. Therefore, this approach is very efficient for estimation of the unknown tube radius, especially if it is of a micron size and difficult to obtain with other measurement techniques. The second extracted parameter is the velocity slip coefficient which characterize the gas–surface interaction. It was found that the interaction between all tested gases with the stainless-steel surface is very close to the diffuse one. Previously reported values of the velocity slip coefficient for interactions involving the same gases and surface suggested less diffusive behaviour, which may be attributed to surface contamination, variations in roughness or the improved measurement method proposed in this work. From the fit of the pressure over time the characteristic time is also obtained. This relaxation time when normalizing by the most probable speed needs to be constant whatever the gas is. This property was checked with the experimental data and the normalized relaxation time constancy is fulfilled with accuracy around 10
$\,\%$
, which confirm the quality of the experimental data.
A new measurement technique for the Poiseuille coefficient is proposed. This technique allows the direct extraction of this coefficient under the assumption of the pressure constancy in the outlet reservoir. The measured Poiseuille coefficient is very close to the numerical data obtained with the fit of the numerical solution of the linearized S-model kinetic equation.
Supplementary material
Supplementary material is available at https://doi.org/10.1017/jfm.2025.10949.
Acknowledgements
The study was supported by the ANR TEGTIC project number ANR-23-CE51-0055-01. F.S. thanks the Aix Marseille University for the support of his stay at the IUSTI laboratory in July 2024 and CNPq (Brazil, grant no. 303429/2022-4).
Declaration of interests
The authors report no conflict of interest.
Appendix A. Expressions for
$\boldsymbol{G_{\kern-1pt p}}$
The theoretical data for
$G_{\kern-1pt p}$
obtained from the S-model (Sharipov Reference Sharipov1996) is interpolated in Sharipov, Graur & Day (Reference Sharipov, Graur and Day2010):
The numerical results based on the LBE (Wu et al. Reference Wu, Zhang, Liu, Zhang and Reese2017) are interpolated by








































