Dosimetric case study of 3-D FiF vs. VMAT techniques in the treatment of H/N tumour

Published online by Cambridge University Press:  25 August 2023

Zhaohui Xie*
Affiliation:
John Patrick University of Health and Applied Sciences, South Bend, IN, USA
*
Corresponding author: Zhaohui Xie; Email: johnxie0228@gmail.com
Rights & Permissions [Opens in a new window]

Abstract

A case study comparing three-dimensional conformal radiation therapy with field-in-field (FiF) technique and volumetric-modulated arc therapy (VMAT) for head/neck (H/N) irradiation, evaluating the differences in the treatment techniques and low doses to critical structures. Compared to VMAT plan, 3D FIF plan offers similar planning target volume coverage and acceptable organs at risk dose. Therefore, 3D FIF is still a feasible alternative for some centres unqualified for IMRT/VMAT worldwide.

Information

Type
Case Study
Copyright
© The Author(s), 2023. Published by Cambridge University Press
Figure 0

Figure 1. The H/N anatomical region. Red = PTV

Figure 1

Figure 2. 3D-CRT fields properties

Figure 2

Figure 3. VMAT fields properties

Figure 3

Table 1. The main characteristics of each delivery mode

Figure 4

Figure 4. The comparison in the DVH for two plans. Triangle = 3D-CRT; square = MAT

Figure 5

Figure 5. The dose distribution for the two plans in the same slide

Figure 6

Figure 6. Volume of isodose levels

Figure 7

Figure 7. Doses (Gy) in OARs

Figure 8

Table 2. The volume of different isodose levels (%). (Unit: cm3)

Figure 9

Table 3. The PTV dose parameters for two techniques

Figure 10

Table 4. shows Doses in OARs. (Unit: Gy)