Transcatheter closure of a membranous ventricular septal defect in a 1.8-kg infant using Amplatzer Duct Occluder II additional size device

Published online by Cambridge University Press:  16 May 2017

Bhavik Champaneri
Affiliation:
Department of Pediatric Cardiology, Amrita Institute of Medical Sciences, Kochi, Kerala, India.
Mahesh Kappanayil
Affiliation:
Department of Pediatric Cardiology, Amrita Institute of Medical Sciences, Kochi, Kerala, India.
Raman K. Kumar*
Affiliation:
Department of Pediatric Cardiology, Amrita Institute of Medical Sciences, Kochi, Kerala, India.
*
Correspondence to: Dr R. K. Kumar, Department of Pediatric Cardiology, Amrita Institute of Medical Sciences, Ponekkara 682041, Kochi, Kerala, India. Tel: +91 9895092746; Fax: 04846681234; E-mail: kumar_rk@yahoo.com
Rights & Permissions [Opens in a new window]

Abstract

Catheter closure of membranous ventricular septal defects is generally not considered feasible in small infants. We report the successful closure of a membranous ventricular septal defect in a 1.8-kg infant with bilateral femoral artery occlusion using Amplatzer Duct Occluder II additional size device. The ventricular septal defect was crossed from the right ventricle, and the device was deployed using transthoracic echocardiographic guidance.

Information

Type
Brief Report
Copyright
© Cambridge University Press 2017 
Figure 0

Figure 1 (a) Parasternal long axis view showing membranous VSD measuring 2.5 mm with left to right shunt. Note the left atrium, left ventricle enlargement. (b) Post device deployment echo, device well away from aortic valve and no residual flow.

Figure 1

Figure 2 Steps of crossing VSD from RV side and device deployment. (a) Diagramatic representation of catheter course in AP projection with heart anatomy. (b) Lateral projection diagramatic representation of Judkin’s right catheter pulled back below pulmonary valve and turned to face posteriorily and terumo wire inserted into posterior placed LV. (c) Lateral angio image of VSD crossing with terumo wire into LV. (d) 4 French long sheath tracked into LV and LV disc of device deployed under flouoro guidance. (e) Under TTE guidance, device being adjusted to LV side of VSD. LV = left ventricle; MPA = main pulmonary artery; RV = right ventricle; SVC = superior vena cavae; IVC = inferior vena cavae; TTE = transthoracic echo; VSD = ventricular septal defect.