Hostname: page-component-7b7567c8c-fvjsw Total loading time: 0 Render date: 2026-11-16T23:08:24.485Z Has data issue: false hasContentIssue false

Development and evaluation of a loop-mediated isothermal amplification (LAMP) diagnostic test for detection of whipworm, Trichuris trichiura, in faecal samples

Published online by Cambridge University Press:  02 April 2020

M.G. Ngari
Affiliation:
Department of Biochemistry, Jomo Kenyatta University of Agriculture and Technology, PO Box 62000, 00200Nairobi, Kenya
I.N. Mwangi
Affiliation:
Centre for Biotechnology Research and Development, Kenya Medical Research Institute (KEMRI), PO Box 54840, 00200Nairobi, Kenya
M.P. Njoroge
Affiliation:
Department of Health, PO Box 24, Kirinyaga County, Kerugoya, Kenya
J. Kinyua
Affiliation:
Department of Biochemistry, Jomo Kenyatta University of Agriculture and Technology, PO Box 62000, 00200Nairobi, Kenya
F.A. Osuna
Affiliation:
Centre for Biotechnology Research and Development, Kenya Medical Research Institute (KEMRI), PO Box 54840, 00200Nairobi, Kenya
B.M. Kimeu
Affiliation:
Department of Biochemistry and Biotechnology, Technical University of Kenya, PO Box 52428, 00200Nairobi, Kenya
P.W. Okanya
Affiliation:
Department of Biochemistry and Biotechnology, Technical University of Kenya, PO Box 52428, 00200Nairobi, Kenya
E.L. Agola*
Affiliation:
Centre for Biotechnology Research and Development, Kenya Medical Research Institute (KEMRI), PO Box 54840, 00200Nairobi, KenyaDepartment of Biochemistry and Biotechnology, Technical University of Kenya, PO Box 52428, 00200Nairobi, Kenya
*
Author for correspondence: E.L. Agola, E-mail: elelo@kemri.org
Rights & Permissions [Opens in a new window]

Abstract

Whipworm infection or trichuriasis caused by Trichuris trichiura is of major public health concern in sub-Saharan Africa, particularly among pre-school and school-going children. It is among the neglected tropical diseases targeted for elimination through mass drug administration (MDA). One of the outcomes of MDA is a rapid decline in levels of infection intensity, making it difficult to monitor effectiveness of control measures using the conventional Kato–Katz procedure, which relies on the microscopic detection of parasite ova in faecal samples. In the present study, a loop-mediated isothermal amplification (LAMP) test was developed for the detection of T. trichiura infection in faecal samples. LAMP technology offers greater sensitivity and specificity than the microscopy-based tests. A set of four specific primers targeting the internal transcribed spacer 2 region of the ribosomal DNA were designed using Primer Explorer software. DNA was extracted from faecal samples using the alkaline lysis method (HotSHOT) and the LAMP reaction performed at 63°C for 1 h. The amplicons were visualized by both gel electrophoresis and with the naked eye following staining with SYBR green dye. Sensitivity and specificity tests were determined using the standard Kato–Katz diagnostic procedure as a reference test. The developed LAMP assay reliably detected T. trichiura DNA in faecal samples, with a specificity and sensitivity of 88% and 77%, respectively. No cross-reactivity was observed with several common helminth parasites. The developed LAMP assay is an appropriate diagnostic method for the detection of T. trichiura DNA in human faecal samples due to its simplicity, low cost, high sensitivity and specificity.

Information

Type
Research Paper
Copyright
Copyright © The Author(s), 2020. Published by Cambridge University Press
Figure 0

Table 1.Primer sequences used for the amplification of Trichuris trichiura ova.

Figure 1

Fig. 1.(a) Agarose gel photo showing results of the LAMP assay when varying primer ratios. Lanes 2, 3, 4 and 5 represent ratios 1:1, 4:2.5, 6:5 and 8:10, respectively. Lane 6 is the negative control (reaction mix without DNA), and Lanes 1 and 7 are 100-bp molecular markers. (b) LAMP visual detection for colour change using the SYBR green dye. Tubes 1, 2, 3 and 4 represent primer ratios 1:1, 4:2.5, 6:5 and 8:10, respectively. Tube 5 is the negative control.

Figure 2

Fig. 2.(a) Agarose gel photo showing amplified fragments at temperatures in the range of 60–65°C for Lanes 2, 3, 4 and 5 representing 60°C, 62°C, 63°C and 65°C, respectively. Lane 6 is the negative control (reaction mix without DNA), Lanes 1 and 7 are 100-bp molecular markers. (b) Detection of amplicon by the naked eye based on colour change using the SYBR green dye. Tubes 1, 2, 3 and 4 represent amplification at temperatures of 60°C, 62°C, 63°C and 65°C, respectively. Tube 5 represents the negative control (reaction mix without DNA).

Figure 3

Fig. 3.(a) Agarose gel showing amplification of isolated egg(s). Lanes 2, 3, 4 and 5 are DNA amplification from 1, 5, 10 and 15 eggs, respectively. Lane 6 is the negative control (reaction mix without DNA) and Lanes 1 and 7 are 100-bp molecular markers. (b) Detection of amplicons using SYBR green dye. Tubes 1, 2, 3 and 4 represent amplifications of 1, 5, 10 and 15, respectively. Tube 5 is the negative control (reaction mix without DNA).

Figure 4

Fig. 4.(a) Agarose gel photo showing results for the specificity of the LAMP assay for Trichuris trichiura. Lanes 2 and 3 are T. trichiura DNA at 82.8 ng/μl and 99.2 ng/μl, respectively. Lane 4 is Schistosoma mansoni DNA at 98.6 ng/μl, Lane 5 is Necator americanus DNA at 90.6 ng/μl and Lane 6 is Ascaris lumbricoides at 50.2 ng/μl. Lane 7 is a negative control (master mix without DNA). Lanes 1 and 8 represent 100-bp molecular markers. (b) Detection using the SYBR green dye. Tubes 1 and 2 represent amplification of T. trichiura DNA, and 3, 4 and 5 are S. mansoni DNA, N. americanus DNA and A. lumbricoides DNA, respectively. Tube 6 represents a negative control (master mix without DNA).

Figure 5

Fig. 5.Agarose gel photo of the LAMP assay amplified products of different concentrations of Trichuris trichiura DNA, following 1:10 serial dilutions, starting with a 98.6 ng/μl DNA concentration (Lane 2) to 98.6 × 10−9 ng/μl (Lane 11). Lane 12 is the negative control (master mix with no DNA), and Lanes 1 and 13 are 100-bp molecular markers.

Figure 6

Table 2.Contingency table comparing LAMP assay with the Kato–Katz technique.