Hostname: page-component-74656f9884-8r8nv Total loading time: 0 Render date: 2026-11-09T22:44:56.661Z Has data issue: false hasContentIssue false

Use of Bivalirudin for a Pediatric Patient with Two Mechanical Heart Valves: a case report

Published online by Cambridge University Press:  17 March 2025

Joshua W. Branstetter*
Affiliation:
Department of Pharmacy, Children’s Healthcare of Atlanta, Atlanta, GA, USA
John Wagner
Affiliation:
Pediatric Cardiology Fellow in Training, Emory University SOM, Atlanta, GA, USA
Hania Zaki
Affiliation:
Department of Pharmacy, Children’s Healthcare of Atlanta, Atlanta, GA, USA
Gary Woods
Affiliation:
Children’s Healthcare of Atlanta, Emory University School of Medicine, Atlanta, GA, USA
Heather Viamonte
Affiliation:
Children’s Healthcare of Atlanta, Emory University School of Medicine, Atlanta, GA, USA
*
Corresponding author: Joshua W. Branstetter; Email: Joshua.branstetter@choa.org
Rights & Permissions [Opens in a new window]

Abstract

Despite advances in the development of systemic anticoagulants, there remain few agents approved for utilisation in patients with mechanical heart valves. Currently, recommendations for periprocedural and long-term anticoagulation in mechanical heart valves include unfractionated heparin or vitamin K antagonists, and there are some reports for off-label use of low-molecular-weight heparins. Emerging data on parenteral direct thrombin inhibitors, such as bivalirudin, have led to increased utilisation in both extracorporeal membrane oxygenation and ventricular assist devices. We present the case of a paediatric patient with rheumatic heart disease who had significant bleeding on unfractionated heparin who successfully received prolonged bivalirudin therapy in the setting of mechanical aortic and mitral heart valves.

Information

Type
Brief Report
Copyright
© The Author(s), 2025. Published by Cambridge University Press
Figure 0

Image 1. Transthoracic Echocardiogram (TTE) in apical 3-chamber view with color doppler showing broad regurgitant jet consistent with severe aortic insufficiency.

Figure 1

Image 2. TTE in parasternal short axis with the aortic valve en face and color comparison again showing a broad regurgitant jet commonly seen in valvulitis.

Figure 2

Image 3. TTE in apical 4 chamber with color doppler over the mitral valve showing an eccentric regurgitant jet with suggestion of pulmonary vein reversal consistent with severe mitral valve regurgitation.

Figure 3

Image 4. TTE in parasternal short axis with the mitral valve en face and color doppler showing a broad regurgitant jet.