Hostname: page-component-74656f9884-npj9w Total loading time: 0 Render date: 2026-11-07T14:48:56.149Z Has data issue: false hasContentIssue false

Numerical simulation of circulation control turbine cascade with Coanda jet and counter-flow blowing at high Mach numbers

Published online by Cambridge University Press:  19 June 2017

Y. Feng*
Affiliation:
School of Energy Science and Engineering, Harbin Institute of Technology, Harbin, China
Y. Song
Affiliation:
School of Energy Science and Engineering, Harbin Institute of Technology, Harbin, China
F. Chen
Affiliation:
School of Energy Science and Engineering, Harbin Institute of Technology, Harbin, China
Rights & Permissions [Opens in a new window]

Abstract

The performance of a circulation-control inlet guide vane that makes use of the Coanda effect was studied numerically in a high Mach number turbine cascade. The effect of different shapes (elliptic and circular) of the Coanda surface at the blade trailing edge was investigated by implementing both a Coanda jet and a counter-flow blowing. Under high subsonic flow conditions, with a total blowing ratio of 3% of the mainstream, the circulation control cascade can reach the same performance as the reference stator with a 13.5% reduction in the axial chord length, with minimal increase of the energy loss coefficient. The Coanda surfaces with small curvature are more efficient in entraining the mainstream flow, and they achieve better aerodynamic performance. The wall attachment of the Coanda jet is improved by employing counter-flow blowing, resulting in a slight increase of both the exit flow angle and the expansion ratio. Under supersonic flow conditions at the cascade exit, it is more difficult for the circulation control cascade to reach the appropriate flow turning due to a premature shock wave, which is absent in the original cascade until the very end of the suction surface.

Information

Type
Research Article
Copyright
Copyright © Royal Aeronautical Society 2017 
Figure 0

Table 1 Geometric parameters of the stator cascade

Figure 1

Figure 1. Sketches of the cascade geometry, Coanda surfaces, and jet slots.

Figure 2

Figure 2. Grid for the turbine cascade without and with the jet slots.

Figure 3

Figure 3. Comparison of streamlines near the aerofoil trailing edge and static pressure distribution along the aerofoil, V∞ = 42.5 m/s, Cμ = 0.031, Re = 1×106 (based on aerofoil chord length).

Figure 4

Figure 4. Performance parameters of the cascades, Ma = 0.60.

Figure 5

Figure 5. Distribution of wall pressure coefficient on the Coanda surfaces, Ma = 0.60.

Figure 6

Figure 6. Distribution of skin friction coefficient on the Coanda surfaces, Ma = 0.60.

Figure 7

Figure 7. Mach number contour and streamlines around the trailing edge, Ma = 0.60.

Figure 8

Figure 8. Performance parameters of the cascades, Ma = 0.85.

Figure 9

Figure 9. Distribution of wall pressure coefficient on the Coanda surfaces, Ma = 0.85.

Figure 10

Figure 10. Distribution of skin friction coefficient on the Coanda surfaces, Ma = 0.85.

Figure 11

Figure 11. Performance parameters of the cascades, Ma = 1.10.

Figure 12

Figure 12. Mach number contour and streamlines around the trailing edge, Ma = 1.10.

Figure 13

Figure 13. Distribution of wall pressure coefficient on the Coanda surfaces, Ma = 1.10.

Figure 14

Figure 14. Distribution of skin friction coefficient on the Coanda surfaces, Ma = 1.10.