Hostname: page-component-7b7567c8c-wxvwp Total loading time: 0 Render date: 2026-11-16T02:59:44.071Z Has data issue: false hasContentIssue false

Hypersonic shock impingement studies on a flat plate: flow separation of laminar boundary layers

Published online by Cambridge University Press:  04 November 2022

Eric Won Keun Chang*
Affiliation:
Centre for Hypersonics, School of Mechanical and Mining Engineering, The University of Queensland, Brisbane, Queensland 4072, Australia
Wilson Y.K. Chan
Affiliation:
Centre for Hypersonics, School of Mechanical and Mining Engineering, The University of Queensland, Brisbane, Queensland 4072, Australia
Timothy J. McIntyre
Affiliation:
Centre for Hypersonics, School of Mathematics and Physics, The University of Queensland, Brisbane, Queensland 4072, Australia
Ananthanarayanan Veeraragavan
Affiliation:
Centre for Hypersonics, School of Mechanical and Mining Engineering, The University of Queensland, Brisbane, Queensland 4072, Australia
*
†Email address for correspondence: ericwk.chang@eng.ox.ac.uk

Abstract

Interactions between shock waves and boundary layers produce flow separations and augmented pressure/thermal loads in hypersonic flight. This study provides details of Mach 7 impinging-shock-flat-plate experiments conducted in the T4 Stalker Tube. Measurements were taken at flow conditions of Mach 7.0 (2.44 MJ kg$^{-1}$) and Mach 7.7 (2.88 MJ kg$^{-1}$) flight enthalpies with a range of freestream unit Reynolds numbers from $1.43 \times 10^{6}$ m$^{-1}$ to $5.01 \times 10^{6}$ m$^{-1}$. A shock generator at $12^{\circ }$ or $16^{\circ }$ to the freestream created an oblique shock which impinged on a boundary layer over a flat plate to induce flow separation. The flow field was examined using simultaneous measurements of wall static pressure, heat transfer and schlieren visualisation. Measured heat transfer along the flat plate without the shock impingement indicated that the boundary layer remained laminar for all flow conditions. The shock impingement flow field was successfully established within the facility test duration. The onset of separation was observed by a rise in wall pressure and a decrease in heat transfer at the location corresponding to the stem of the separation shock. Downstream of this initial rise, an increased pressure and higher heating loads were observed. The heat-transfer levels also indicated an immediate boundary layer transition due to the shock impingement. The separation data of the present work showed good agreement with our previous work on shock impingement on heated walls (Chang et al., J. Fluid Mech., vol. 908, 2021, pp. 1–13). A comparison with the previous scaling indicated that the separation also relates to the pressure ratio and the wall temperature parameter.

Information

Type
JFM Papers
Copyright
© The Author(s), 2022. Published by Cambridge University Press
Figure 0

Table 1.Facility nozzle-supply (subscript $s$) and freestream (subscript $\infty$) properties.

Figure 1

Figure 1.Typical nozzle-supply pressure traces for the test conditions listed in table 1. The vertical lines indicate durations at approximate constant nozzle-supply pressure.

Figure 2

Figure 2.Pitot pressure inspection: (a) time history of M7B Pitot pressure; (b) comparison of the nozzle simulation with the mean pressure.

Figure 3

Figure 3.Schematic for the instrumented flat plate and shock generator configurations. All dimensions in millimetres.

Figure 4

Figure 4.Typical surface instrumentation signals during the test, M7B condition: (a) static pressure; (b) heat transfer.

Figure 5

Figure 5.Mean static pressure distributions along the flat plate.

Figure 6

Figure 6.Surface heat transfer along the flat plate: M7B condition ($H_s = 2.37$ MJ kg$^{-1}$, $Re_{\infty } = 4.92 \times 10^{6}$ m$^{-1}$).

Figure 7

Figure 7.Surface heat transfer along the flat plate: M7.7B condition ($H_s = 2.88$ MJ kg$^{-1}$, $Re_{\infty } = 3.09 \times 10^{6}$ m$^{-1}$).

Figure 8

Figure 8.Time evolution of the M7B, 12$^{\circ }$ shock generator flow field: (a) $t = 0.47$ ms, (b) $t = 0.93$ ms, (c) $t = 1.60$ ms, (d) $t = 2.00$ ms, (e) $t = 2.93$ ms, (f) $t = 3.67$ ms, (g) $t = 3.80$ ms and (h) $t = 10.00$ ms.

Figure 9

Figure 9.Time histories of static pressure for the M7B condition, 12$^{\circ }$ shock generator: (a) $x = 121$ mm, upstream boundary layer; (b) $x = 179.5$ mm, onset of separation; (c) $x = 264.5$ mm, upstream of shock impingement; (d) $x = 309.5$ mm, downstream of shock impingement.

Figure 10

Figure 10.Time histories of heat transfer for the M7B, 12$^{\circ }$: (a) $x = 102$ mm, upstream boundary layer; (b) $x = 183$ mm, onset of separation; (c) $x = 264$ mm, upstream of shock impingement; (d) $x = 291$ mm, downstream of shock impingement.

Figure 11

Figure 11.Measured signals inside the separation bubble: (a) pressure, $x = 244.5$ mm; (b) heat transfer, $x = 237$ mm.

Figure 12

Figure 12.Establishment time comparisons for the impinging shock geometry, M7B condition.

Figure 13

Figure 13.Mean properties of the 12$^{\circ }$ shock generator, M7A and M7B: (a) static pressure and (b) Stanton number. The blue line indicates the inviscid shock impingement point.

Figure 14

Figure 14.Mean properties of the 12$^{\circ }$ shock generator, M7.7B: (a) static pressure and (b) Stanton number.

Figure 15

Figure 15.Mean properties of the 16$^{\circ }$ shock generator, M7B: (a) static pressure and (b) Stanton number.

Figure 16

Figure 16.Maximum heating correlation developed from the present data, along with data from the literature.

Figure 17

Figure 17.Effect of wall-to-freestream temperature ratio on the scaled separation length.

Figure 18

Figure 18.Relationship between the scaled separation length (Davis & Sturtevant 2000) and flow parameters of the present data: (a) pressure ratio, (b) $\varLambda _{1}$. Lines represents linear fits and $n$ is the slope of each line in log–log coordinates.