Hostname: page-component-6898cfcb55-th4rj Total loading time: 0 Render date: 2026-11-11T13:25:48.496Z Has data issue: false hasContentIssue false

Role of volatility and thermal properties in droplet spreading: a generalisation to Tanner's law

Published online by Cambridge University Press:  17 May 2024

Zhenying Wang*
Affiliation:
Department of Aeronautics and Astronautics, Kyushu University, Nishi-Ku, Motooka 744, Fukuoka 819-0395, JapanInternational Institute for Carbon-Neutral Energy Research (WPI-I2CNER), Kyushu University, Nishi-Ku, Motooka 744, Fukuoka 819-0395, Japan
George Karapetsas
Affiliation:
Department of Chemical Engineering, Aristotle University of Thessaloniki, Thessaloniki 54124, Greece
Prashant Valluri
Affiliation:
Institute of Multiscale Thermofluids, School of Engineering, University of Edinburgh, Edinburgh EH9 3JL, UK
Chihiro Inoue
Affiliation:
Department of Aeronautics and Astronautics, Kyushu University, Nishi-Ku, Motooka 744, Fukuoka 819-0395, Japan
*
†Email address for correspondence: zhenying.wang@aero.kyushu-u.ac.jp

Abstract

Droplet spreading is ubiquitous and plays a significant role in liquid-based energy systems, thermal management devices and microfluidics. While the spreading of non-volatile droplets is quantitatively understood, the spreading and flow transition in volatile droplets remains elusive due to the complexity added by interfacial phase change and non-equilibrium thermal transport. Here we show, using both mathematical modelling and experiments, that the wetting dynamics of volatile droplets can be scaled by the spatial–temporal interplay between capillary, evaporation and thermal Marangoni effects. We elucidate and quantify these complex interactions using phase diagrams based on systematic theoretical and experimental investigations. A spreading law of evaporative droplets is derived by extending Tanner's law (valid for non-volatile liquids) to a full range of liquids with saturation vapour pressure spanning from $10^1$ to $10^4$ Pa and on substrates with thermal conductivity from $10^{-1}$ to $10^3\ {\rm W}\ {\rm m}^{-1}\ {\rm K}^{-1}$. In addition to its importance in fluid-based industries, the conclusions also enable a unifying explanation to a series of individual works including the criterion of flow reversal and the state of dynamic wetting, making it possible to control liquid transport in diverse application scenarios.

Information

Type
JFM Papers
Creative Commons
Creative Common License - CCCreative Common License - BY
This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http://creativecommons.org/licenses/by/4.0), which permits unrestricted re-use, distribution and reproduction, provided the original article is properly cited.
Copyright
© The Author(s), 2024. Published by Cambridge University Press.
Figure 0

Figure 1.(a) A single component droplet with small aspect ratio, $\hat {H}_0/\hat {R}_0$, sitting on a solid substrate surrounded by its own vapour and non-condensing gas. Here $c_{sat}$ denotes the saturation vapour concentration. We use $\hat T_{g}$ and $c_{g}$ to denote the temperature and vapour concentration of the gas phase, which remain constant. Here $\hat {\rho }$ is the liquid density, $\hat {\mu }$ is the liquid viscosity, $\hat {k}$ is the thermal conductivity of the liquid, $\hat {c_p}$ is the specific heat capacity of the liquid, $\hat {H}_{solid}$ is the thickness of the substrate, $\hat {k}_{solid}$ is the thermal conductivity of the substrate, $T_{w}$ is the temperature at the downward side of the substrate and $\vec n$ and $\vec t$ are the outward units vectors acting in normal and tangential directions to the interface. The centre of droplet base, O, is defined as the origin of the coordinate. (b) Governing equations that are considered in the gas, liquid and solid phases, along with the boundary equations at the central axis, the liquid–gas interface and the liquid–solid interface.

Figure 1

Figure 2.Experimental set-up for (a) droplet spreading and (b) microPIV visualisation of flow field inside the droplet.

Figure 2

Table 1.Thermophysical properties of representative liquids at 293 K except FC-72 (298 K). 1-butanol, 2-propanol and FC-72 were utilised in present experiments. Water, 2-propanol, methanol, ethanol and chloroform were utilised in previous studies on circulation reversal (Ristenpart et al.2007; Xu et al.2010; Li et al.2015) as marked in figure 5. Alkanes (e.g. heptane and hexane) were utilised in the study of Shiri et al. (2021) on the influence of thermal Marangoni flow on droplet geometry as marked in figure 7.

Figure 3

Table 2.Thermal conductivity of representative substrate materials. Copper, SUS430 and glass were utilised in present study. Glass was utilised in the work of Xu et al. (2010) and Hu & Larson (2006). Polydimethylsiloxane (PDMS) was utilised in the work of Ristenpart et al. (2007).

Figure 4

Figure 3.Evolution of flow state for an evaporative droplet on a thermal conductive substrate. The three stages are classified according to the state of internal flow, where continuous outwards capillary flow dominates droplet spreading at the initial stage, the Marangoni flow develops at the second stage and balances with the capillary flow at the third stage. The key dimensionless numbers in this case are set as $Ja^* = 5\times 10^{-3}$, $Bi = 10^{-4}$ and $Ma = 10^{-2}$.

Figure 5

Figure 4.Decomposition of the dominating mechanisms in wetting dynamics of evaporative droplets.

Figure 6

Figure 5.Phase diagram for the relative strength of thermal Marangoni flow to capillary flow. (a–e) Decomposition of surface velocity $u_{s}$ to thermal Marangoni velocity $u_{tg}$ and capillary velocity $u_{ca}$, corresponding to letters (a–e) in the colourmap. Sketches I, II and III indicate the dominating mechanism at different regimes of the phase diagram. The experimental data by Xu et al. (2010) (1a, water on glass of thickness 1 mm; 1b, water on glass of thickness 0.15 mm; 1c, IPA on glass of thickness 1 mm), Ristenpart et al. (2007) ($2\ \mathrm {\mu }\textrm {l}$ droplets of: 2a, methanol; 2b, ethanol; 2c, IPA; 2d, chloroform; on PDMS of thickness 4 mm) and Li et al. (2015) (3a to 3b with leftward dotted arrows and representative deposition patterns: $2.5\ \mathrm {\mu }\textrm {l}$ droplets on glass substrate of 30, 50, 65 and $80\,^\circ \textrm {C}$) are marked out, which indicate the flow reversal inside the droplet with changing environmental settings. Note that the dotted line presents the criterion for the formation of SP, and does not necessarily correspond to the contour line of $|u_{tg,max}|/|u_{ca,max}|=1$.

Figure 7

Figure 6.Flow pattern near three phase contact line visualised by tracer particles where the tracing tracks of fluorescent particles are overlap of 100 continuous frames: (a) a 0.5$\ \mathrm {\mu }\textrm {l}$ butanol droplet on slide glass and (b) a 0.5$\ \mathrm {\mu }\textrm {l}$ IPA droplet on slide glass.

Figure 8

Figure 7.Phase diagram for the spreading rate of droplets along with demonstrations of flow and temperature fields in representative conditions. Contour lines of the spreading exponent are marked out with corresponding values. Experimental results by Shiri et al. (2021) ((1) alkanes on glass substrates with decreasing thickness) and Kumar et al. (2022) ((2) HFE 7500 to 7100 with increasing volatility) are presented with yellow dotted arrows. Experimental results in our research are marked with stars numbered as ${\unicode{x2460}}$ butanol on 1.1 mm glass, ${\unicode{x2461}}$ butanol on 1.0 mm copper, ${\unicode{x2462}}$ IPA on 1.1 mm glass, ${\unicode{x2463}}$ IPA on 1.0 mm SUS430, ${\unicode{x2464}}$ IPA on 1.0 mm copper, ${\unicode{x2465}}$ FC-72 on 1.1 mm glass, ${\unicode{x2466}}$ FC-72 on 1.0 mm SUS430, ${\unicode{x2467}}$ FC-72 on 1.0 mm copper (${\unicode{x2460}}\unicode{x2013} {\unicode{x2467}}$ are cases with substrate temperature $T_{sub}= 20\,^\circ \textrm {C}$), ${\unicode{x2468}}$ FC-72 on 1.0 mm copper ($T_{sub} = 25\,^\circ \textrm {C}$), ${\unicode{x2469}}$ FC-72 on 1.0 mm copper ($T_{sub}= 35\,^\circ \textrm {C}$) and ${\unicode{x246A}}$ FC-72 on 1.0 mm copper ($T_{sub} = 45\,^\circ \textrm {C}$).

Figure 9

Table 3.Values of $Ja^*$ and $Bi$ for cases ${\unicode{x2460}}$ to ${\unicode{x246A}}$ (expressed in scientific notation).

Figure 10

Figure 8.(a) Spreading behaviours of droplets at substrates with different thermal conductivity ($T_{sub} = 20\,^{\circ }\textrm {C}$): ${\unicode{x2460}}$ IPA on 1.1 mm glass, ${\unicode{x2461}}$ IPA on 1.0 mm SUS430, ${\unicode{x2462}}$ IPA on 1.0 mm copper, ${\unicode{x2463}}$ butanol on 1.1 mm glass, ${\unicode{x2464}}$ butanol on 1 mm copper. (b) Spreading behaviours of droplets with different volatility on 1.0 mm copper substrate: ${\unicode{x2461}}$ butanol at $T_{sub} = 20\,^{\circ }\textrm {C}$, ${\unicode{x2464}}$ IPA at $T_{sub} = 20\,^{\circ }\textrm {C}$, ${\unicode{x2467}}\unicode{x2013} {\unicode{x246A}}$ FC-72 at $T_{sub} = 20\,^{\circ }\textrm {C}$, $25\,^{\circ }\textrm {C}$, $35\,^{\circ }\textrm {C}$, $45\,^{\circ }\textrm {C}$. These cases correspond with the mark numbers in figure 7.

Figure 11

Table 4.Experimental (Exp.) spreading exponent n in comparison with the numerical (Num.) value by matching its position ($Ja^*$, $Bi$) in the phase diagram. Numbers ${\unicode{x2460}}\unicode{x2013} {\unicode{x246A}}$ correspond with the cases marked in figure 7. Deviations between experimental and numerical results exist mainly in the high-volatility and low-substrate-conductivity region (small $Ja^*$ and large $Bi$, e.g. case ${\unicode{x2465}}$), where the heat dissipation into the gas phase is no longer negligible.

Supplementary material: File

Wang et al. supplementary movie 1

Simulation results indicating the development of flow field inside an evaporating droplet on thermally conductive substrates with dimensionless number Ja* = 5×10−3, Bi = 10−4, Ma = 10−2, corresponding to Figure 3 in the main context.
Download Wang et al. supplementary movie 1(File)
File 18.5 MB
Supplementary material: File

Wang et al. supplementary movie 2

Flow field near three phase contact line visualized by tracer particles: (a) a 0.5 μL Butanol droplet (speed up by 20 times), and (b) a 0.5 μL IPA droplet (slow down by 3 times) on slide glass, corresponding to Figure 6 in the main context.
Download Wang et al. supplementary movie 2(File)
File 8.7 MB
Supplementary material: File

Wang et al. supplementary movie 3

Phase diagram for the spreading rate of droplets along with demonstrations of how flow and temperature fields develop in representative conditions, corresponding to Figure 7 in the main context.
Download Wang et al. supplementary movie 3(File)
File 13.5 MB