Hostname: page-component-6898cfcb55-w5hgh Total loading time: 0 Render date: 2026-11-11T07:27:34.359Z Has data issue: false hasContentIssue false

Interrelation of phase-averaged volume force and capacitance of dielectric barrier discharge plasma actuators

Published online by Cambridge University Press:  14 November 2016

M. Kuhnhenn*
Affiliation:
Institute for Fluid Mechanics and Aerodynamics, Technische Universität Darmstadt, Flughafenstraße 19, 64347 Griesheim, Germany
B. Simon
Affiliation:
Institute for Fluid Mechanics and Aerodynamics, Technische Universität Darmstadt, Flughafenstraße 19, 64347 Griesheim, Germany
I. Maden
Affiliation:
Institute for Fluid Mechanics and Aerodynamics, Technische Universität Darmstadt, Flughafenstraße 19, 64347 Griesheim, Germany
J. Kriegseis
Affiliation:
Institute of Fluid Mechanics, Karlsruhe Institute of Technology (KIT), Kaiserstraße 10, 76131 Karlsruhe, Germany
*
†Email address for correspondence: kuhnhenn@sla.tu-darmstadt.de

Abstract

Simultaneous measurements of the phase-averaged velocity distribution and the underlying discharge quantities of a dielectric barrier discharge plasma actuator (PA) are performed at $10~\text{k}\text{Hz}$ discharge frequency to investigate the interplay of the discharge and the surrounding flow. The underlying velocity information for the force estimation is obtained by means of phase-averaged particle image velocimetry; the discharge quantities are determined from a Lissajous-figure analysis. The results uncover a clear cause–effect relation between the phase-dependent effective discharge capacitance of the PA and the resulting spatiotemporal volume-force distributions. From this novel insight, it must be concluded that the instantaneous effective discharge intensity dominates the momentum-transfer rate rather than the formerly assumed operating voltage.

Information

Type
Rapids
Copyright
© 2016 Cambridge University Press 
Figure 0

Figure 1.(a) Set-up of a DBD PA with two electrodes $b_{1}$, $b_{2}$ and a dielectric with a thickness of $d$. The field of view (FOV) is shown for clarity (dashed box). In addition, the electric measurement equipment is indicated. (b) Charge $Q=C_{P}V_{P}$ and operating voltage $V$ of the same DBD actuator plotted in a Lissajous figure ($Q{-}V$ cyclogram) with characteristic capacitances $C_{0}$ and $C_{eff}$ (dashed lines). Furthermore, the acquisition points for the PIV measurements and the effective phases of the respectively determined velocity fields are emphasized.

Figure 1

Figure 2.Statistical significance of the PIV data: convergence of the relative standard deviation $\unicode[STIX]{x1D70E}^{\ast }=\unicode[STIX]{x1D70E}_{u}/\bar{u}$ for (a) four characteristic locations of the wall jet at $\unicode[STIX]{x1D719}=0$ and (b) the fully developed wall jet $\unicode[STIX]{x2463}$ for all phase angles as indicated in figure 1(b).

Figure 2

Figure 3.Decomposition of the volume force $F_{x}$ into convective, diffusive and time-dependent parts. The error bars indicate the reproducibility based on three measurements for the overall volume force.

Figure 3

Figure 4.Contribution of all NSE terms to the force distribution (phase angle $\unicode[STIX]{x1D719}=\unicode[STIX]{x03C0}$ is shown): (a) local acceleration $\unicode[STIX]{x1D70C}\,\unicode[STIX]{x2202}u/\unicode[STIX]{x2202}t$, (b) convective terms $\unicode[STIX]{x1D70C}u_{j}\,\unicode[STIX]{x2202}u_{i}/\unicode[STIX]{x2202}x_{j}$, (c) diffusive terms $\unicode[STIX]{x1D702}\,\unicode[STIX]{x2202}^{2}u_{i}/\unicode[STIX]{x2202}x_{j}\unicode[STIX]{x2202}x_{j}$, (d) overall volume force $f_{x}$ as the sum of all terms (a–c) according to equation (4.1). (e) The time-averaged volume force $\overline{f_{x}}$ is added for comparison purposes.

Figure 4

Figure 5.Volume-force distribution $f_{x}(x,y,\unicode[STIX]{x1D719})$ for all evaluated phase angles $\unicode[STIX]{x1D719}$. The positive and negative half-cycles appear in (a,c,e,g) and (b,d,f,h) respectively, as denoted at the top of the figure; (a,b), (c,d), (e,f) and (g,h) accordingly provide the force fields during discharge onset/transition, effective discharge intensity with $C_{eff}$, collapse of the plasma and dark period with $C_{0}$ respectively.

Figure 5

Figure 6.Phase-averaged actuator volume force: (a) interrelation of the phase-averaged capacitance $C$ and the volume force $F_{x}$; note that the left ordinate starts from zero, whereas the right ordinate centres around zero; (b) comparison of normalized magnitudes $\tilde{F_{x}}(\unicode[STIX]{x1D719})=F_{x}(\unicode[STIX]{x1D719})/\text{max}|F_{x}(\unicode[STIX]{x1D719})|$ with the literature.