Emergency pacing via the umbilical vein of a neonate with congenital complete atrioventricular block: a report of two cases

Published online by Cambridge University Press:  25 April 2023

Noboru Tanaka*
Affiliation:
Department of Pediatrics, Juntendo University Faculty of Medicine, Bunkyo City, Tokyo, Japan
Kotoko Matsui
Affiliation:
Department of Pediatrics, Juntendo University Faculty of Medicine, Bunkyo City, Tokyo, Japan
Mana Harada
Affiliation:
Department of Pediatrics, Juntendo University Faculty of Medicine, Bunkyo City, Tokyo, Japan
Hideo Fukunaga
Affiliation:
Department of Pediatrics, Juntendo University Faculty of Medicine, Bunkyo City, Tokyo, Japan
Ken Takahashi
Affiliation:
Department of Pediatrics, Juntendo University Faculty of Medicine, Bunkyo City, Tokyo, Japan
Masahiko Kishiro
Affiliation:
Department of Pediatrics, Juntendo University Faculty of Medicine, Bunkyo City, Tokyo, Japan
Toshiaki Shimizu
Affiliation:
Department of Pediatrics, Juntendo University Faculty of Medicine, Bunkyo City, Tokyo, Japan
*
Author for correspondence: Noboru Tanaka, Department of Pediatrics, Juntendo University Faculty of Medicine, Bunkyo City, Tokyo, Japan. E-mail: nobonobo@juntendo.acjp
Rights & Permissions [Opens in a new window]

Abstract

We report two cases of successful emergency pacing via the umbilical vein in neonates with congenital complete atrioventricular block. The first patient, a neonate with normal cardiac anatomy, underwent emergency temporary pacing via the umbilical vein under echocardiographic guidance. The patient underwent permanent pacemaker implantation on postnatal day 4. The second patient, a neonate with heterotaxy syndrome, underwent emergency temporary pacing through the umbilical vein under fluoroscopic guidance. The patient underwent permanent pacemaker implantation on postnatal day 17.

Information

Type
Brief Report
Copyright
© The Author(s), 2023. Published by Cambridge University Press
Figure 0

Figure 1.Electrocardiogram showing complete atrioventricular block before the temporary pacing.

Figure 1

Figure 2.X-ray showing 2-Fr fixed electrophysiology catheter in the right ventricular.

Figure 2

Figure 3.(a) X-ray image showing the permanent VVI pacemaker implanted in the neonate 4 days after birth; (b) electrocardiogram showing pacing signals after VVI pacemaker implantation.

Figure 3

Figure 4.Electrocardiogram showing complete atrioventricular block before the temporary pacing.

Figure 4

Figure 5.X-ray showing the umbilical vein positioned on the left side of the patient’s body.

Figure 5

Figure 6.Fluoroscopy image showing that the umbilical vein (UV) flowed into the portal vein (PV) and then bent to the right to connect to the ductus venosus.

Figure 6

Figure 7.X-ray showing the temporary pacing via the umbilical vein in the eonate at 3 hours after birth.

Figure 7

Figure 8.(a) X-ray image showing the permanent VVI pacemaker implanted in the neonate 17 days after birth; (b) electrocardiogram showing pacing signals after VVI pacemaker implantation.