Hostname: page-component-6898cfcb55-zkb6p Total loading time: 0 Render date: 2026-11-11T07:46:32.263Z Has data issue: false hasContentIssue false

Edwards valve-in-valve implantation in tricuspid position

Published online by Cambridge University Press:  16 May 2017

Maria Álvarez-Fuente*
Affiliation:
Pediatric Cardiology Department, Hospital Ramón y Cajal, Madrid, Spain
Nikolaus A. Haas
Affiliation:
Pediatric Cardiology Department, Klinikum Universität München, München, Germany
Maria Jesus del Cerro
Affiliation:
Pediatric Cardiology Department, Hospital Ramón y Cajal, Madrid, Spain
*
Correspondence to: M. Álvarez-Fuente, Pediatric Cardiology, Hospital Ramón y Cajal, Carretera de Colmenar Viejo Km 9,1, 2034, Madrid, Spain. Tel: +34 649 68 09 61; Fax: +34913369027; E-mail: mery1812@hotmail.com
Rights & Permissions [Opens in a new window]

Abstract

We present two cases of percutaneous Sapien XT valve-in-valve implantation in the tricuspid position: a 20-year-old man with severe congenital pulmonary stenosis and percutaneous valvuloplasty, who required surgical implantation of two protheses, pulmonary and tricuspid, and a 12-year-old boy with CHD and a degenerated tricuspid prosthesis. We implanted three Sapien XT valve-in-valves, two in the tricuspid position and one in the pulmonic position. Sapien XT valve-in-valve implantation in the tricuspid position is feasible and can decrease the number of surgeries in CHD patients.

Information

Type
Brief Report
Copyright
© Cambridge University Press 2017 
Figure 0

Figure 1Valve implantation steps during catheterization. Echocardiography pre and post valve implantation.

Figure 1

Figure 2Valve implantation steps during catheterization.