Hostname: page-component-74656f9884-j7cmm Total loading time: 0 Render date: 2026-11-08T10:25:08.281Z Has data issue: false hasContentIssue false

Assessment of the dosimetric consequences of prostate movement through rectal distension for patients receiving 3DCRT

Published online by Cambridge University Press:  06 January 2011

D.J. Redding*
Affiliation:
Radiotherapy Department, Weston Park Hospital, Sheffield, UK
C.M. Bragg
Affiliation:
Radiotherapy Physics Department, Weston Park Hospital, Sheffield, UK
*
Correspondence to: Debra Redding, Radiotherapy Department, Weston Park Hospital, Whitham Road, Sheffield S10 2SJ, UK. E-mail: Debra.Redding@sth.nhs.uk
Rights & Permissions [Opens in a new window]

Abstract

Purpose: To investigate the dosimetric consequences of rectal distension at the time of the planning computed tomography (CT) scan and any resultant prostate movement on the planned dose delivery for patients receiving three-dimensional conformal radiotherapy (3DCRT) to the prostate.

Methods and materials: 25 prostate cancer patients whose planning CT scan demonstrated a full rectum were rescanned after following a laxative protocol. Rectal dimensions on the two scans and 3DCRT treatment plans produced on each plan were compared. The dosimetric implications of changes in rectal size on the treatment plans and the delivered dose were determined. Statistical significance was evaluated with the Wilcoxon signed ranks test.

Results: Significant differences in rectal size were found between the initial CT scan and the rescan. The corresponding median change in prostate position was 4.7 mm. The use of planning scans with a full rectum, that is unrepresentative of the rectum, during treatment causes significant reductions in planning target volume (PTV) minimum dose (median reduction 33.7%) and coverage by the 95% isodose (median reduction 3.7% of the PTV).

Conclusion: Rectal distension on the initial planning scan can lead to significant PTV underdosage. Patients presenting with large initial rectal fillings must be rescanned in order to avoid a systematic underdosing of the PTV.

Information

Type
Original Article
Copyright
Copyright © Cambridge University Press 2011
Figure 0

Figure 1. A sagittal view of a CT image from a patient with a distended rectum, demonstrating the rectal length (L) and the three anterior–posterior rectal diameters measured in this study: at the levels of the base of the prostate (W1), the middle of the prostate (W2) and the inferior extent of the prostate (W3).

Figure 1

Figure 2. A representative axial slice from a patient’s initial scan showing the contoured volumes on both the initial scan and the rescan, following registration of the datasets: Bladder initial scan (pink) and rescan (light green), rectum initial scan (yellow) and rescan (dark green), PTV initial scan (blue) and rescan (red). The purple contour shows the position of the CTV on the initial scan.

Figure 2

Table 1. Rectal and bladder characteristics

Figure 3

Table 2. Comparison of doses between the plans produced on the initial ct scan and the rescan

Figure 4

Table 3. Spearman’s rank correlation coefficients (R) between rectal size and PTV dose for all scans and for the initial scan and rescan separately

Figure 5

Figure 3. The magnitude of the change in prostate position in the three axes for all patients between the initial CT scan and the rescan.

Figure 6

Table 4. Comparison of dosimetric parameters for the plan produced on the initial scan when applied to the anatomy of the initial scan (“initial scan”) and when applied to the rescan (“registration rescan”)

Figure 7

Table 5. Comparison of dosimetric parameters for the plan produced on the rescan scan when applied to the anatomy of the rescan (“rescan”) and the plan produced on the initial scan when applied to the anatomy of the rescan (“registration rescan”)