Hostname: page-component-74656f9884-rngvg Total loading time: 0 Render date: 2026-11-05T11:25:40.953Z Has data issue: false hasContentIssue false

Durable bistable auxetics made of rigid solids

Published online by Cambridge University Press:  06 November 2017

Xiao Shang
Affiliation:
Department of Mechanical Engineering, McGill University, Montreal, Quebec H3A 0C3, Canada
Lu Liu
Affiliation:
Department of Mechanical Engineering, McGill University, Montreal, Quebec H3A 0C3, Canada
Ahmad Rafsanjani
Affiliation:
John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, Massachusetts 02138, USA
Damiano Pasini*
Affiliation:
Department of Mechanical Engineering, McGill University, Montreal, Quebec H3A 0C3, Canada
*
a) Address all correspondence to this author. e-mail: damiano.pasini@mcgill.ca

Abstract

Bistable Auxetic Metamaterials (BAMs) are a class of monolithic perforated periodic structures with negative Poisson’s ratio. Under tension, a BAM can expand and reach a second state of equilibrium through a globally large shape transformation that is ensured by the flexibility of its elastomeric base material. However, if made from a rigid polymer, or metal, BAM ceases to function due to the inevitable rupture of its ligaments. The goal of this work is to extend the unique functionality of the original kirigami architecture of BAM to a rigid solid base material. We use experiments and numerical simulations to assess performance, bistability, and durability of rigid BAMs at 10,000 cycles. Geometric maps are presented to elucidate the role of the main descriptors of the BAM architecture. The proposed design enables the realization of BAM from a large palette of materials, including elastic-perfectly plastic materials and potentially brittle materials.

Information

Type
Invited Articles
Copyright
Copyright © Materials Research Society 2017 
Figure 0

FIG. 1. Original BAM Architecture: (a) building block geometry, (b) unit cell in its closed and open state (c) a natural latex rubber sample with 6 × 6 modules in its undeformed and fully open configuration.29 Cellular BAM made of rigid solid: (d) building block geometry, (e) unit cell in its closed and open state (f), a cellular BAM sample with 6 × 6 modules fabricated from Delrin® Acetal Resin in its undeformed and fully open configuration. The sample is sandwiched between two Plexiglas plates to prevent out-of-plane deformation during tensile testing.

Figure 1

FIG. 2. Design of compliant ligaments for rigid BAM structures. (a) G0 straight ligament with sharp edges, and (d) arc ligament with G1 optimized fillets. Blending points are highlighted in red, and dark portions of ligaments in insets (a) and (d) are speckled regions used for DIC. (b, e) Finite element results for strain distribution in the direction of the ligament longitudinal axis y are compared with (c, f) experimental strains obtained by Digital Image Correlation (DIC) for G0 and G1 designs, respectively.

Figure 2

FIG. 3. Bistability curves and failure plots for cellular BAM with straight ligaments and sharp edges (G0). (a) Strain energy density versus strain for unit cells with given values of l/L under periodic boundary conditions, (b) η versus l/L showing the change in bistability, (c) maximum von Mises stress versus strain for unit cells with given values of l/L under periodic boundary conditions, (d) ζ versus l/L showing the change in failure.

Figure 3

FIG. 4. Force-time curves for a representative unit cell at the 1st (solid line), 1085th (dashed line), and 1200th (dotted line) cycle. (a) Initial ligament, (b) ligament geometry after 1085 cycles, and (c) broken ligament at 1200 cycles.

Figure 4

FIG. 5. Contour plots obtained by numerical analysis showing how bistability is controlled by l/L and t/L for designs with (a) G0 ligament and (b) G1 optimized ligament.

Figure 5

FIG. 6. Contour plots of failure with respect to l/L and t/L for (a) G0 ligament and (b) G1 optimized ligament.

Figure 6

FIG. 7. Durability test (a) fixture designed for the durability test providing the necessary boundary conditions to the unit cell sample, (b) contour plot experimentally obtained with respect to l/L and t/L for G0 ligaments, (c) number of cycles tested to failure against l/L comparing the durability level for cellular BAM samples with G0 ligaments and G1 optimized ligaments with a fixed t/L = 0.0075.

Figure 7

FIG. 8. Geometric maps illustrating how bistability, failure, and durability are controlled by t/L and l/L for cellular patterns with (a) G0 and (b) G1 optimized ligaments.

Shang et al supplementary material

Shang et al supplementary material 1

Download Shang et al supplementary material(Video)
Video 27.2 MB