Hostname: page-component-74656f9884-2dmjx Total loading time: 0 Render date: 2026-11-07T11:12:17.732Z Has data issue: false hasContentIssue false

Application of an improved TEM-EDS protocol based on charge balance for accurate chemical analysis of sub-micrometric phyllosilicates in low-grade metamorphic rocks

Published online by Cambridge University Press:  06 December 2024

Edoardo Sanità*
Affiliation:
Università di Pisa, Dipartimento di Scienze della Terra, Via Santa Maria, 53, Pisa, Italy
Roberto Conconi
Affiliation:
Università degli Studi di Milano-Bicocca, Dipartimento di Scienze dell’Ambiente e della Terra, Piazza della Scienza 4, Milano, Italy
Sofia Lorenzon
Affiliation:
Università di Pisa, Dipartimento di Scienze della Terra, Via Santa Maria, 53, Pisa, Italy
Maria Di Rosa
Affiliation:
Università di Pisa, Dipartimento di Scienze della Terra, Via Santa Maria, 53, Pisa, Italy
Giancarlo Capitani
Affiliation:
Università degli Studi di Milano-Bicocca, Dipartimento di Scienze dell’Ambiente e della Terra, Piazza della Scienza 4, Milano, Italy
Enrico Mugnaioli
Affiliation:
Università di Pisa, Dipartimento di Scienze della Terra, Via Santa Maria, 53, Pisa, Italy
*
Corresponding author: Edoardo Sanità; Email: edoardo.sanita@dst.unipi.it
Rights & Permissions [Opens in a new window]

Abstract

Determining the chemical composition of sub-micrometer rock-forming minerals is still a challenging task. The electron probe micro-analyzer (EPMA) is considered the most accurate analytical way to obtain chemical data on amorphous and crystalline materials. However, performing EPMA analyses on sub-micrometer-sized grains is uncertain not recommended as the risk of obtaining analyses contaminated from the surrounding phases. A transmission electron microscope (TEM) equipped with an energy dispersive X-ray spectrometer (EDS) provides a greater spatial resolution, making it possible to obtain trustworthy chemical information on sub-micrometer-sized material. In this work, we present a fast and cheap data-reduction protocol for TEM-EDS chemical analysis, where k-factors derived experimentally for each element of interest and absorption correction are implemented. The results are compared with those determined using standardless and non-corrected TEM-EDS protocols. The k-factor for oxygen plays a fundamental role and its value should be calculated from compounds similar to the phase of interest. For absorption correction, the contribution of hydrogen during structural formula recalculation is taken into account, like a lower net valence of oxygen. The robustness of this protocol was tested by performing TEM-EDS analyses on white mica grains from metapelites, belonging to the Internal Ligurian Units exposed in the Northern Apennines, the chemical composition of which is well constrained. Such a protocol has proven to provide high-quality results from both statistical and crystallo-chemical perspectives. Remarkably, the tested data-reduction protocol for TEM-EDS analysis provided chemical compositions consistent with the EPMA results previously obtained from the same samples.

Information

Type
Original Paper
Copyright
© The Author(s), 2024. Published by Cambridge University Press on behalf of The Clay Minerals Society
Figure 0

Figure 1. Geological map of the sampled area (modified from Sanità et al., 2024) in which the Internal Ligurian Units are shown with different colors. The locations of the samples used in this work are indicated by red points.

Figure 1

Figure 2. (a) Microtextural features of S1 foliation (dashed yellow line) at the optical microscope. (b) Back-scattered electron image of S1 foliation (dashed yellow line). White mica and chlorite grains are indicated (white arrows). Dark-field TEM images showing representative white mica grains typical for each investigated sample: sample ULI3aT (c); sample ULI8T (d); sample ULI14T (e); and sample ULI22aT (f).

Figure 2

Table 1. List of the extrapolated and theoretical k-factors used in this paper

Figure 3

Figure 3. STL (standardless method) vs NC (non-corrected method) data-reduction plots for the TEM-EDS analyses. Only the cations showing significant variations are reported. The red lines indicate a 1:1 ratio between the quantification performed with the two data reductions.

Figure 4

Figure 4. NC (non-corrected method) vs ACM (absorption correction method) plots for the TEM-EDS analyses. Only the cations showing significant variations are reported. The red lines indicate a 1:1 ratio between the quantification performed with the two data reductions.

Figure 5

Figure 5. ACM (absorption correction method) vs STL (standardless method) data-reduction plots for the TEM-EDS analyses. Only the cations showing significant variations are reported. The red lines indicate a 1:1 ratio between the quantification performed with the two data reductions.

Figure 6

Table 2. Mean values and related standard deviations of cations are reported for all the data-reduction procedures considered in this paper

Figure 7

Table 3. EPMA analysis of the same samples analyzed by TEM-EDS

Figure 8

Figure 6. (a) Si-Altot and (b) Si-K diagrams for EPMA and TEM-EDS (after ACM) analyses. The blue line in (a) indicates the celadonite—muscovite solid solution with Tschermak (TK) substitution.

Supplementary material: File

Sanità et al. supplementary material

Sanità et al. supplementary material
Download Sanità et al. supplementary material(File)
File 127.4 KB