Hostname: page-component-74656f9884-kv2lp Total loading time: 0 Render date: 2026-11-06T04:38:22.981Z Has data issue: false hasContentIssue false

Numerical and experimental performance estimation for a ExoFing - 2 DOFs finger exoskeleton

Published online by Cambridge University Press:  23 November 2021

G Carbone*
Affiliation:
Department of Mechanical, Energy and Management Engineering, DIMEG, University of Calabria, Rende, Italy
M Ceccarelli
Affiliation:
Department of Industrial Engineering, DII, University of Rome Tor Vergata, Rome, Italy
C. E. Capalbo
Affiliation:
Department of Mechanical, Energy and Management Engineering, DIMEG, University of Calabria, Rende, Italy
G Caroleo
Affiliation:
Department of Mechanical, Energy and Management Engineering, DIMEG, University of Calabria, Rende, Italy
C Morales-Cruz
Affiliation:
Instituto Politécnico Nacional, GIIM: Group of Research and Innovation in Mechatronics, 07700 Mexico City, Mexico
*
*Corresponding author. E-mail: giuseppe.carbone@unical.it
Rights & Permissions [Opens in a new window]

Abstract

This paper presents a numerical and experimental validation of ExoFing, a two-degrees-of-freedom finger mechanism exoskeleton. The main functionalities of this device are investigated by focusing on its kinematic model and by computing its main operation characteristics via numerical simulations. Experimental tests are designed and carried out for validating both the engineering feasibility and effectiveness of the ExoFing system aiming at achieving a human index finger motion assistance with cost-oriented and user-friendly features.

Information

Type
Research Article
Copyright
© The Author(s), 2021. Published by Cambridge University Press
Figure 0

Figure 1. A conceptual scheme of ExoFing.

Figure 1

Figure 2. A kinematic design of ExoFing.

Figure 2

Table I. Design parameters and link lengths of the finger exoskeleton for the scheme in Figs. 2 and 3.

Figure 3

Figure 3. A CAD model of ExoFing design with a front view.

Figure 4

Figure 4. Computed angles for metacarpal phalange angular motion.

Figure 5

Figure 5. Computed angles for distal phalange angular motion.

Figure 6

Figure 6. Computed feasible motion of point C using the proposed kinematic model.

Figure 7

Figure 7. Snapshots of the exoskeleton multibody simulation during a closure motion: (a) starting; (b) during motion; and (c) final position.

Figure 8

Figure 8. Computed values of the input motor 1 torque for the case shown in Fig. 7.

Figure 9

Figure 9. Computed values of the input motor 2 torque for the case shown in Fig. 7.

Figure 10

Figure 10. Computed values of the power consumption of motor 1 for the case shown in Fig. 7.

Figure 11

Figure 11. Computed values of the power consumption of motor 2 for the case shown in Fig. 7.

Figure 12

Figure 12. Design of experimental setup at LARM2 in Rome: (a) a conceptual scheme and (b) a laboratory setup. (1: temperature sensor, 2: EMG, 3: current sensor, 4: IMU’s, 5: motors, and 6: Arduino).

Figure 13

Figure 13. Snapshots of the exoskeleton motion during a test with sensors: (a) starting position; (b) intermediate position; and (c) fully closed position.

Figure 14

Figure 14. Experimental test results in terms of: (a) angular inputs for motors and (b) power consumption.

Figure 15

Figure 15. Experimental test results for the case shown in Fig. 14 in terms of: (a) electrical activity of finger muscles measured via an EMG sensor and (b) temperature measured at ExoFing attaching surface.

Figure 16

Figure 16. Results for the simulated and measured motion in terms of orientation of: (a) MCP angle and (b) DIP+PIP angle.

Figure 17

Figure 17. Results for the simulated and measured motion for the case in Fig. 16 in terms of angular velocity of: (a) MCP and (b) DIP+PIP.