Hostname: page-component-74656f9884-c52kr Total loading time: 0 Render date: 2026-11-07T01:11:32.935Z Has data issue: false hasContentIssue false

Isothermal and thermo-mechanical fatigue behavior of 16Mo3 steel coated with high-velocity oxy-fuel sprayed nickel-base alloy under uniaxial as well as biaxial-planar loading

Published online by Cambridge University Press:  21 September 2017

Dirk Kulawinski*
Affiliation:
Institute of Materials Engineering, Technische Universität Bergakademie Freiberg, Freiberg 09599, Germany
Markus Hoffmann
Affiliation:
Institute of Materials Engineering, Technische Universität Bergakademie Freiberg, Freiberg 09599, Germany
Tim Lippmann
Affiliation:
Institute of Materials Engineering, Technische Universität Bergakademie Freiberg, Freiberg 09599, Germany
Götz Lamprecht
Affiliation:
Institute of Materials Engineering, Technische Universität Bergakademie Freiberg, Freiberg 09599, Germany
Anja Weidner
Affiliation:
Institute of Materials Engineering, Technische Universität Bergakademie Freiberg, Freiberg 09599, Germany
Sebastian Henkel
Affiliation:
Institute of Materials Engineering, Technische Universität Bergakademie Freiberg, Freiberg 09599, Germany
Horst Biermann
Affiliation:
Institute of Materials Engineering, Technische Universität Bergakademie Freiberg, Freiberg 09599, Germany
*
a) Address all correspondence to this author. e-mail: dirk.kulawinski@siemens.com

Abstract

The ferritic steel 16Mo3 coated with the nickel-base alloy IN625mod by high-velocity oxy-fuel (HVOF) spraying was investigated under uniaxial and biaxial fatigue loading at 200 and 500 °C. Furthermore, bulk HVOF-sprayed specimens of the coating material IN625mod were also investigated under uniaxial isothermal fatigue loading at 200 and 500 °C. Moreover, the thermo-mechanical fatigue behavior of 16Mo3 was studied under in-phase (IP) and out-of-phase (OP) loading between 200 and 500 °C. The fatigue lives of the bulk coating and the compound material are presented. In particular, the thermo-mechanical OP loading leads to a strong reduction of the lifetimes compared to the IP loading. A conservative estimation of the fatigue lives of the thermo-mechanical loading can be given by isothermal tests at 500 °C. The comparison of the uniaxial loading with the biaxial loading cases shows reasonable coincidence by using the distortion energy hypothesis according to von Mises.

Figure 0

TABLE I. Chemical composition in wt% of the ferritic steel 16Mo3 (substrate material) for both production routes and of the nickel-base superalloy coating material IN625mod measured by Glow Discharge Optical Emission Spectroscopy (GDOES).

Figure 1

FIG. 1. Scanning electron microscopy (SEM) image in back-scattered electron contrast of the microstructure of 16Mo3 for both production routes. (a) Rod material with fine ferrite grains and carbides at the grain boundaries (section perpendicular to the rod axis). (b) Sheet material with coarser ferrite grains and line-like arrangement of the perlite, thus a rolling direction is present (section parallel to the rolling direction of the sheet material).

Figure 2

FIG. 2. SEM image in back-scattered electron contrast of the microstructure of (a) composite material with a IN625mod coating (1) on the substrate material 16Mo3 (2) and (b) a higher magnification of the IN625mod coating.

Figure 3

FIG. 3. Technical drawing of the compound specimens, (a) cylindrical and (b) cruciform geometry. The coating within the figures is marked in gray. All dimensions are given in mm and include the coating thickness of 200 µm.

Figure 4

TABLE II. Uniaxial mechanical properties (mean values based on 3 tests at each temperature and material) of the substrate material of 16Mo3 and the bulk coating material IN625mod.

Figure 5

FIG. 4. Cyclic deformation curves with the course of the stress amplitude and mean stress of the uniaxial fatigue tests of the (a) coating material IN625mod at 500 °C for two total strain amplitudes and of IN625 coated 16Mo3 and in comparison to the substrate material 16Mo3 at (b) 200 °C and (c) 500 °C.

Figure 6

FIG. 5. Cyclic deformation curves with the course of the stress amplitude and the mean stress of the uniaxial TMF tests of compound specimens and uncoated reference specimens under (a) IP loading and (b) OP loading.

Figure 7

FIG. 6. Cyclic deformation curves of the biaxial-planar fatigue test with the course of the equivalent stress amplitude and the mean stress of the compound specimens under biaxial-planar fatigue loading at (a) 200 °C and (b) 500 °C.

Figure 8

FIG. 7. Investigation of the crack mechanism by (a) light optical microscopy of the surface of the composite material (TMF OP loading with strain amplitude of 0.4%) with a network of cracks and parts of flakes off coating. (b) A closer look to this TMF OP specimen on the crack network with circumferential cracks, which were merged by small longitudinal cracks. (c) SEM image secondary electron contrast which shows (arrow) a longitudinal crack in the coating and a delamination of the coating at the LCF specimen at 500 °C tested with a strain amplitude of 0.6%. (d) SEM image of the LCF specimen at 500 °C tested with a strain amplitude of 0.6% in back scatter electron contrast of a longitudinal crack with a crack initiation within the coating and a crack propagation into the substrate material as well as a crack deflection at the interface of the coating and substrate.

Figure 9

FIG. 8. Macroscopic crack orientation within the cruciform specimen under isothermal biaxial-planar fatigue at (a) 200 °C (Δεeq/2 = 0.6%) and (b) 500 °C (Δεeq/2 = 0.4%).

Figure 10

TABLE III. Parameters of the Basquin and Manson–Coffin relationships for isothermal fatigue of the coated substrate 16Mo3 steel at 500 °C.

Figure 11

FIG. 9. Isothermal lifetimes of the compound specimens with an IN625mod coating on the 16Mo3 substrate under unaixial as well as biaxial loading at both temperatures of (a) 200 °C and (b) 500 °C in comparison to the bulk coating material IN625mod and uncoated substrate material 16Mo3. (c) Uniaxial thermo-mechanical lifetimes under IP and OP loading of the compound specimens in comparison to the fatigue live curves of isothermal fatigue at 500 °C of the coated material and TMF IP loading of the uncoated substrate material 16Mo3.42

Supplementary material: PDF

Kulawinski et al supplementary material

Figure S1 and Tables S1-S2

Download Kulawinski et al supplementary material(PDF)
PDF 117 KB