Hostname: page-component-7b7567c8c-kwt9d Total loading time: 0 Render date: 2026-11-14T15:49:27.030Z Has data issue: false hasContentIssue false

Elimination of lock-in phenomenon in vortex-induced vibration by passive modal control

Published online by Cambridge University Press:  02 April 2024

Fuqing Luo
Affiliation:
School of Aeronautics, Northwestern Polytechnical University, Xi'an 710072, PR China
Chuanqiang Gao
Affiliation:
School of Aeronautics, Northwestern Polytechnical University, Xi'an 710072, PR China
Zhen Lyu
Affiliation:
School of Aeronautics, Northwestern Polytechnical University, Xi'an 710072, PR China
Weiwei Zhang*
Affiliation:
School of Aeronautics, Northwestern Polytechnical University, Xi'an 710072, PR China
*
†Email address for correspondence: aeroelastic@nwpu.edu.cn

Abstract

Theoretical analysis and numerical results have shown that frequency lock-in in vortex-induced vibration (VIV) is caused by the instability of the structural mode rather than a resonant response to external excitations. However, there is a lack of experimental evidence supporting relevant theoretical research findings. This study investigates VIV suppression with a passive modal controller (PMC) for a circular cylinder at Reynolds numbers $Re = 60$ and $Re = 40$, using experiments to distinguish the effects of stable and unstable wake modes. Comparative analysis before and after the implementation of the PMC reveals significant reduction in the vibration amplitude and the disappearance of the lock-in phenomenon at $Re = 60$. The vibration frequency closely follows the vortex shedding frequency after control, while dynamic mode decomposition of the flow field indicates that the wake mode is dominant. For $Re = 40$, the vibration is eliminated and the flow becomes steady. Additionally, the root loci of the coupled system are investigated before and after the PMC implementation via linear stability analysis. The results indicate that the PMC can alter the dynamic characteristics of the original system, causing the structural mode and PMC mode to couple when approaching the PMC frequency. Then, the interaction typically improves the stability of the structural mode. Finally, a parametric study is conducted in the experiment, as well as a linear stability analysis. The study provides experimental evidence that stability control of the structural mode is the key to suppressing VIV and eliminating the lock-in phenomenon.

Information

Type
JFM Papers
Copyright
© The Author(s), 2024. Published by Cambridge University Press
Figure 0

Figure 1.Schematic of a one-degree-of-freedom transversely vibrating cylinder with a PMC.

Figure 1

Figure 2.Sketch of (a) the rotating water channel and measurement techniques and (b) the experimental model of the cylinder with a PMC.

Figure 2

Figure 3.Distribution of (a) flow velocity and (b) turbulence intensity in the cross-section of the rotating channel at a rotational speed of $N = 0.102$ rad s$^{-1}$.

Figure 3

Figure 4.(a) The maximum transverse displacement $Y^{max}$ and (b) the response frequency $F$ varying with the reduced natural frequency of the cylinder $F_{y}$ in the experiment and CFD/CSD simulation for $Re = 60$.

Figure 4

Figure 5.Identified results under the training signal compared with those of direct numerical simulations for (a) $Re = 60$ and (b) $Re = 40$.

Figure 5

Figure 6.Root loci of the coupled system without control for (a) $Re = 60$ and (b) $Re = 40$.

Figure 6

Figure 7.(a) The maximum transverse displacement $Y^{max}$ and (b) the response frequency varying with the reduced natural frequency of the cylinder with and without PMC control for $Re = 60 \text{ and } m_{y}^{*} = 21$. The PMC parameters are as follows: mass ratio $\varepsilon = 5.35\,\%$, damping $\lambda _{d} = 5\,\%$ and frequency $F_{d} = 0.14$.

Figure 7

Figure 8.Comparisons of time responses and PSD results for (a,c) the plain cylinder ($F_{y} = 0.169$) and (b,d) the cylinder attached to a PMC, where $f = 2.56$ Hz corresponds to the reduced frequency $F = 0.165$ and $f = 2.1$ Hz corresponds to the reduced frequency $F = 0.135$.

Figure 8

Figure 9.Root loci of the controlled system for $Re = 60$: (a) root loci versus reduced natural frequency $F_{y}$; (b) real and (c) imaginary parts of the root loci.

Figure 9

Figure 10.The vorticity of the flow field and the dominant mode obtained by DMD at $Re = 60$ for (a,d) the elastic cylinder without control, (b,e) the elastic cylinder with PMC control and (c,f) the stationary cylinder.

Figure 10

Figure 11.(a) The vorticity of the flow field and (b) the dominant mode obtained by DMD at $Re = 40$ for the elastic cylinder without control.

Figure 11

Figure 12.Comparisons of (a) time responses and (b) PSD results at $Re = 40$ for the elastic cylinder with and without control.

Figure 12

Figure 13.The vorticity of the flow field at $Re = 40$ for (a) the controlled cylinder and (b) the stationary cylinder.

Figure 13

Figure 14.The root loci and their corresponding real parts at $Re = 40$ for (a,b) the uncontrolled system and (c,d) the controlled system with PMC.

Figure 14

Figure 15.The maximum vibration amplitude varying with the reduced natural frequency of the PMC at $Re = 60$ for $F_{y} = 0.163$.

Figure 15

Figure 16.The root loci and their corresponding real parts of the controlled system varying with the reduced natural frequency of the cylinder at $Re = 60$ for (a,b) $\varOmega = 0.6$ and (c,d) $\varOmega = 1.1$.

Figure 16

Figure 17.(a) The root loci and (b) the real parts of the root loci of the controlled system varying with the reduced natural frequency of the PMC at $Re = 60$ for $F_{y} = 0.163$, compared with (c) the maximum amplitude of the controlled cylinder in the experiment.

Figure 17

Figure 18.The root loci and their corresponding real parts of the controlled system varying with the reduced natural frequency of the cylinder at $Re = 60$ for (a,b) $\varOmega = 0.74$ and (c,d) $\varOmega = 1.08$.

Figure 18

Figure 19.Time responses of the cylinder at $Re = 60$ for $F_{y} = 0.163$, as well as the maximum vibration amplitude $Y^{max}$ varying with the PMC mass ratio.

Figure 19

Figure 20.Time responses of the cylinder at $Re = 60$ for $F_{y} = 0.163$, as well as the maximum vibration amplitude $Y^{max}$ varying with the PMC damping coefficient.

Figure 20

Figure 21.Transverse vibration amplitude of the cylinder as a function of the reduced natural frequency obtained by FSI simulation and forced response simulation.

Figure 21

Figure 22.(a) Time responses and (b,c) PSD results of the cylinder for structural damping $\lambda _{y} = 0.04$ and PMC control obtained by FSI simulation.

Supplementary material: File

Luo et al. supplementary movie 1

Successful PMC control at Re = 60
Download Luo et al. supplementary movie 1(File)
File 7.6 MB
Supplementary material: File

Luo et al. supplementary movie 2

Failed PMC control at Re = 60
Download Luo et al. supplementary movie 2(File)
File 9.4 MB