Transcatheter balloon angioplasty of internal pulmonary artery bands to improve pulmonary blood flow: a case series

Published online by Cambridge University Press:  30 May 2024

Ashwin Srivatsav*
Affiliation:
Pediatrics, Baylor College of Medicine, Houston, TX, USA
Lindsay Eilers
Affiliation:
Pediatric Cardiology, Texas Children’s Hospital, Houston, TX, USA
Asra Khan
Affiliation:
Pediatric Cardiology, Texas Children’s Hospital, Houston, TX, USA
Gary Stapleton
Affiliation:
Pediatric Cardiology, Medical City Children’s Hospital, Dallas, TX, USA
*
Corresponding author: A. Srivatsav; Email: ar.srivatsav@gmail.com
Rights & Permissions [Opens in a new window]

Abstract

Pulmonary artery banding (PAB) is used to restrict pulmonary blood flow in select patients with large left-to-right intracardiac shunts or unrestrictive pulmonary blood flow prior to eventual surgical repair or palliation. More recently, surgical placement of an internal or intraluminal PAB (IPAB) has been used to restrict pulmonary circulation. Here we present two patients who underwent balloon angioplasty of the IPAB to treat cyanosis and improve pulmonary blood flow.

Information

Type
Brief Report
Copyright
© The Author(s), 2024. Published by Cambridge University Press
Figure 0

Figure 1. Punch used to create a 4-mm fenestration in a glutaraldehydepreserved bovine pericardial patch.

Figure 1

Figure 2. Transthoracic echocardiogram performed for patient 1. (a) Pre-balloon angioplasty Doppler of IPAB with peak velocity > 5 m/sec. (b) Parasternal short axis view with colour Doppler performed the day following balloon angioplasty of IPAB. (c) Post-balloon angioplasty Doppler with peak velocity 4.2 m/sec. IPAB = internal or intraluminal pulmonary artery banding.

Figure 2

Figure 3. Angiograms for patient 1: (a) Lateral projection of RV angiogram showing the IPAB (blue arrow) with narrow, faint contrast jet (red arrow) coming through the fenestration. (b) Balloon angioplasty of IPAB using a 7-mm balloon with slight waist seen at full inflation (blue arrow). RV = right ventricular; IPAB = internal or intraluminal pulmonary artery banding.

Figure 3

Figure 4. Axial and sagittal view from computed tomography angiography for patient 1 obtained 5 months after BA of IPAB demonstrating a patent fenestration (blue arrows) measuring 4.8 mm. BA = balloon angioplasty; IPAB = internal or intraluminal pulmonary artery banding.