Hostname: page-component-7b7567c8c-2n9c9 Total loading time: 0 Render date: 2026-11-16T12:45:10.341Z Has data issue: false hasContentIssue false

Thin liquid films in a funnel

Published online by Cambridge University Press:  11 August 2021

T.-S. Lin
Affiliation:
Department of Applied Mathematics, National Yang Ming Chiao Tung University, Hsinchu 30010, Taiwan
J.A. Dijksman
Affiliation:
Physical Chemistry and Soft Matter, Wageningen University & Research, Stippeneng 4, 6708WE Wageningen, The Netherlands
L. Kondic*
Affiliation:
Department of Mathematical Sciences and Center for Applied Mathematics and Statistics, New Jersey Institute of Technology, Newark, NJ 07102, USA
*
†Email address for correspondence: kondic@njit.edu

Abstract

We explore flow of a completely wetting fluid in a funnel, with particular focus on contact line instabilities at the fluid front. While the flow in a funnel may be related to a number of other flow configurations as limiting cases, understanding its stability is complicated due to the presence of additional azimuthal curvature, as well as due to convergent flow effects imposed by the geometry. The convergent nature of the flow leads to thickening of the film, therefore influencing its stability properties. In this work, we analyse these stability properties by combining physical experiments, asymptotic modelling, self-similar type of analysis and numerical simulations. We show that an appropriate long-wave-based model, supported by the input from experiments, simulations and linear stability analysis that originates from the flow down an incline plane, provides a basic insight allowing an understanding of the development of contact line instability and emerging length scales.

Information

Type
JFM Papers
Copyright
© The Author(s), 2021. Published by Cambridge University Press
Figure 0

Figure 1.(a) Solidworks wire sketch of the $47^{\circ }$ funnel. Note that the technical drawing mentions $45^{\circ }$; printing imperfections can somewhat modify the opening angle, which is therefore always measured after printing. (b) Photo of the experimental set-up including the latex sheet, stopper and green-light illumination. The beaker that collects the polydimethylsiloxane (PDMS) is visible underneath the funnel. Here, $S$ indicates the radius of the stopper used as initial barrier that releases the fluid. (c) Solidworks drawing of the $35^{\circ }$ funnel. (d) Coordinate system variables used in the description of the fluid behaviour (solid lines). The light-blue surface delineated with the dotted line indicates the initial fluid volume and position as created by the stopper at distance $r_{c0}$ (dotted arrow) from the origin of the funnel geometry; the thickness of the film referenced in the text, $h_i$, is measured in the vertical direction (therefore, along the short stopper dimension). The dashed arrow indicates the flow direction of the thin film. The arrow denoted by $g$ indicates the direction of gravity.

Figure 1

Figure 2.(a–d) Flow examples for the $60^{\circ }$, $47^{\circ }$, $35^{\circ }$ and $11^{\circ }$ opening angles, respectively. The width of each image is ${\sim}60\ \textrm {mm}$, as indicated by the dark circle that demarcates the edge of the fluid volume before onset of the flow. See also (a) supplementary movie 1; (b) supplementary movie 2; (c) supplementary movie 3; (d) supplementary movie 4.

Figure 2

Table 1.Experimental results for the flow in a funnel as the opening angle and the initial film thickness, $h_i$, are varied (the latter is controlled via varying fluid volume, $V$). The columns are the funnel angle, $\alpha$, the initial fluid volume, $V$, the initial distance to the funnel centre, $r_{c0}$, the distance at which instability is observed, $r_{c1}$, the initial film height (in the $z$ direction), $h_i$, and the number of fingers observed, $N_{exp}$. Errors reported are standard deviations. If no standard deviation is reported, only one movie is available with a camera angle such that $r_{c1}$ could be extracted. Full datasets for experiments carried out also using PDMS of different viscosity, for additional fluid volumes and recorded using different camera angles are available, see supplementary table 1.

Figure 3

Figure 3.(a) Front propagation as a function of time for the setting from figure 2. The middle part shows the onset of fingers, where they become countable and at which point we define $r_{c1}$. (b) The dark front edge allows for fingertip position tracking along lines (red) of pixels towards the centre of the funnel (orifice). (c) A kymograph for the $60^{\circ }$, $h_i = 5$ mm case shows the tip position as a function of time. The initial part in the red square (duration of which is approximately 4 s) features an initially constant tip displacement rate. Examples of this initial fingertip position dynamics are shown in panel (d) for three different opening angles $60^{\circ }$, $47^{\circ }$ and $35^{\circ }$ for the same initial $h_i = 5\ \textrm {mm}$. Dash–dotted lines are straight lines as a guide to the eye to show the average tip speed for each value of $\alpha$. The time window shown in panel (d) corresponds approximately to the horizontal dimension of the red square in the kymograph shown in panel (c). Note the increase of the average speed with a decrease of $\alpha$, a point discussed further in § 4.2.

Figure 4

Figure 4.Constant flux flow: (a) funnel, azimuthally symmetric flow; (b) incline, unperturbed flow (for simplicity we use the same variable $r$ for the both flows; in panel (b) $r$ stands for the downhill coordinate). The initial condition (dashed) for both (a,b) is specified by (4.1). The film profiles are shown at times $10$, $20$, $30$ and $40$ (solid lines). The speed (c) and the maximum height of the film (d) for the funnel flow (solid red) and for incline plane flow (dashed blue). The dotted (black) line in panel (c) shows the flow speed for a flow down an incline as discussed in the text; the difference between the computed and theoretical speed illustrates the (minor) influence of the initial transient behaviour. Here, the inclination angle is $\alpha = 60^{\circ }$, the initial front position is $r_{c0} = 80$ and $b_0 = 0.01$.

Figure 5

Figure 5.Constant flux flow in a funnel: influence of the precursor film thickness for azimuthally symmetric flow. In all panels of the figure, the solid (blue), dashed (red) and dotted (black) lines correspond to $b_0=0.005$, $0.01$ and $0.02$, respectively. (a) Film profiles at $t=45$, (b) precursor films, (c) speed of the spreading front and (d) maximum film height. Here $\alpha =60^{\circ }$ and $r_{c0}=80$.

Figure 6

Figure 6.Constant volume flow in a funnel: predictions based on self-similar approach. (a) Front position ($R-r_f$), (b) front speed ($\textrm {d}r_f/\textrm {d}t$) in (4.11) and (4.12) (note log–log scale in panel (b)). Here $R=90$ and $\hat {c}=1370$, corresponding to the same funnel angle and volume used later in figure 7.

Figure 7

Figure 7.Constant volume flow: (a) funnel, azimuthally symmetric flow; (b) incline, unperturbed flow. The initial condition (dashed) is the same for (a,b) and is specified by (4.14). The film profiles are shown at times $50$, $100$, $150$, $200$ and $250$ (solid lines). The speed (c) and the maximum height of the film (d) for the funnel flow (solid red) and incline plane flow (dashed blue) (note log–log scale). The dotted (black) lines in (c,d) plot the self-similar solutions (4.9)–(4.10), respectively; note that (4.10) applies to the thickness behind the capillary ridge, leading to an approximately constant offset to the numerical solution for the maximum height. Slight deviation of the numerical solution from the expected scaling for very early times illustrate the minor influence of the initial transient behaviour. Here, the inclination angle is $\alpha = 60^{\circ }$, the initial front position is $r_{c0} = 80$, $w=10$ and $b_0 = 0.01$.

Figure 8

Figure 8.Funnel flow: constant fluid volume spreading as the opening angle $\alpha$ is varied. (a) Film profiles at $t=250$. The initial conditions are taken to be the same, shown by the dashed line. The position of the spreading front and the maximum film height are shown in (b,c), respectively (note log–log scale in (c)). Here, the initial front position is $r_{c0} = 80$, $w=10$ and $b_0 = 0.01$.

Figure 9

Figure 9.Film profiles in a funnel (‘F’, constant volume) and on an incline plane (‘P’, constant flux). The former is the film profile at $t=50$ in figure 7(a). The latter is a travelling wave solution with the film thickness behind the front corresponding to the thickness at the inclination point of ‘F’. This thickness, $h_0$, determines the scale that is used in the LSA.

Figure 10

Figure 10.Time evolution of a film on an incline plane (P) and in a funnel (F). The initial condition is specified by (4.14). The results are plotted at the times at which the experimentally observed instability radius, $r_{c1}$, is reached. Note that the shown range of $r$, $40$, is the same for all figure panels. The initial volume corresponds to that experimentally used for the film height of 5 mm for $\alpha = 60^{\circ }$, $47^{\circ }$ and $35^{\circ }$, and of 2.5 mm for $\alpha = 11^{\circ }$, see table 1.

Figure 11

Table 2.Results and predictions of the linear stability analysis for the experimental fluid volumes. The initial film thickness $h_0 (r_{c0}) = 1.0$. The columns are as follows: $\alpha$ – the funnel opening angle, similar to the experimental values, see table 1; $w$ – the width of the initial condition in time-dependent simulations as used in figure 10; $r_{c1}$ – the position at which instability is observed in the experiments; $h_0$ at $r_{c1}$ – as obtained in the simulations for funnel flow, see the text for details; $q_m$ – the most unstable wavenumber obtained by LSA; $q_c$ – critical wavenumber obtained by LSA; $\lambda _m = {2 {\rm \pi}/q_m}$; $N_{LSA}$ – prediction for the number of fingers based on $\lambda _m$ and $r_{c1}$. The values used for $r_{c0}$ (initial front position) and those from the experiments are listed in table 1; note that the listed values of $w$ combined with the specified values of $r_{c0}$ and $h_0 (r_{c0})$ lead to the same fluid volume as in the experiments.

Figure 12

Figure 11.Funnel: average finger spacing wavelength, $\lambda$, versus opening angle, $\alpha$, including experiments (Exp, filled green symbols) for which $r_{c1}$ is available (see table 1), as well as matching linear stability analysis (LSA, open black symbols) predictions from table 2. For completeness we plot the results for all available values of $h_i$ per angle. Symbols indicate $h_i$: $\square$ – $h_i = 5$ mm for $60^{\circ }$, $47^{\circ }$, $35^{\circ }$, and $h_i = 2.5$ mm for $11^{\circ }$; ${\triangle}$ – $h_i = 7$ mm for $60^{\circ }$; $\triangleleft$ – $h_i = 7$ mm for $47^{\circ }$; $\triangleright$ – $h_i = 3$ mm for $11^{\circ }$; $\diamond$ – $h_i = 4$ mm for $11^{\circ }$.

Figure 13

Figure 12.Results of LSA for a liquid film on an incline plane with different $D$. The precursor film thickness is $b_0=0.01$.

Lin et al. supplementary movie 1

See pdf file for movie caption

Download Lin et al. supplementary movie 1(Video)
Video 6.2 MB

Lin et al. supplementary movie 2

See pdf file for movie caption

Download Lin et al. supplementary movie 2(Video)
Video 6.1 MB

Lin et al. supplementary movie 3

See pdf file for movie caption

Download Lin et al. supplementary movie 3(Video)
Video 9.7 MB

Lin et al. supplementary movie 4

See pdf file for movie caption

Download Lin et al. supplementary movie 4(Video)
Video 9.1 MB
Supplementary material: PDF

Lin et al. supplementary material

Captions for movies 1-4

Download Lin et al. supplementary material(PDF)
PDF 37.1 KB
Supplementary material: File

Lin et al. supplementary material

Supplementary table and drawings

Download Lin et al. supplementary material(File)
File 302.6 KB