Hostname: page-component-74656f9884-2dmjx Total loading time: 0 Render date: 2026-11-07T12:58:33.009Z Has data issue: false hasContentIssue false

Simple magnetic spectrometer for ions emitted from laser-generated plasma at 1010 W/cm2 intensity

Published online by Cambridge University Press:  22 May 2018

L. Torrisi*
Affiliation:
Dipartimento di Scienze Fisiche – MIFT, Università di Messina, V.le F.S. D'Alcontres 31, 98166 S. Agata, Messina, Italy
G. Costa
Affiliation:
Dipartimento di Scienze Fisiche – MIFT, Università di Messina, V.le F.S. D'Alcontres 31, 98166 S. Agata, Messina, Italy
*
Author for correspondence: L. Torrisi, Dipartimento di Scienze Fisiche – MIFT, Università di Messina, V.le F.S. D’Alcontres 31, 98166 S. Agata, Messina, Italy. E-mail: lorenzo.torrisi@unime.it

Abstract

Plasmas were generated by 3 ns pulsed lasers at 1064 nm wavelength using intensities of about 1010 W/cm2 irradiating solid targets with a different composition. The ion emission was investigated with time-of-flight measurements giving information of the ion velocity, charge state generation, and ion energy distribution. Measurements use a coil to generate a magnetic field suitable to deflect ions toward a Faraday cup and/or a secondary electron multiplier.

Ion acceleration of the order of hundred eV per charge state, plasma temperature of the order of tens eV, charge states up to about 4+, and Boltzmann energy distributions were obtained in carbon, aluminum, and copper targets.

The presented results represent useful plasma characterization methods for many applications such as the new generation of laser ion sources, pulsed laser deposition techniques, and post ion acceleration systems.

Information

Type
Research Article
Copyright
Copyright © Cambridge University Press 2018 
Figure 0

Fig. 1. Scheme of the experimental set-up with vacuum chamber for laser–matter interaction and magnetic spectrometer analysis chamber (a) and photo of the apparatus (b).

Figure 1

Fig. 2. Magnetic field versus applied voltage reaching a maximum value of about 0.35 T (a), photo of the used solenoid (b), and of the electromagnet polar expansion view from the 0° aperture of the spectrometer chamber employed to control the system alignment (c).

Figure 2

Fig. 3. TOF spectra acquired by the ICR detector, relative to the ions arriving to the collimators, placed before the magnetic deflector, relative to the laser irradiation of polyethylene (a), aluminum (b), and copper (c) target.

Figure 3

Fig. 4. Typical examples of IC-TOF spectra of collimated (1 mm) and deflected Al (a) and Cu (b) ions by a magnetic field of 0.15 and 0.2 T, respectively.

Figure 4

Fig. 5. Typical WEM-TOF spectra obtained irradiating PE (a), Al (b), and Cu (c) targets and using a magnetic field of 0.08, 0.175, and 0.2 T, respectively.

Figure 5

Fig. 6. Ion velocity distributions obtained plotting the WEM ion peak areas as a function of the ion velocity for PE (a), Al (b), and Cu (c) plasmas. The fits were obtained using the CBS (9) function.

Figure 6

Table 1. The three components of the ion velocity, thermal, adiabatic expansion, and Coulombian, evaluated for the different ions emitted from PE, Al, and Cu plasmas

Figure 7

Fig. 7. CCD images of the plasma plume for PE (top), Al (middle), and Cu (bottom) targets irradiated in the same experimental conditions.

Figure 8

Fig. 8. COMSOL multiphysics simulations concerning the detection of deflected Al1+ (a), Al2+ (b), and Al3+ (c) ions by 0.175 T magnetic field, and plot of the particle velocity as a function of the deflection angle (d).