Hostname: page-component-7b7567c8c-wxvwp Total loading time: 0 Render date: 2026-11-16T05:27:24.229Z Has data issue: false hasContentIssue false

Bubble departure and sliding in high-pressure flow boiling of water

Published online by Cambridge University Press:  23 May 2024

Artyom Kossolapov
Affiliation:
Department of Nuclear Science and Engineering, Massachusetts Institute of Technology, Cambridge, MA 02138, USA
Matthew T. Hughes
Affiliation:
Department of Nuclear Science and Engineering, Massachusetts Institute of Technology, Cambridge, MA 02138, USA
Bren Phillips
Affiliation:
Department of Nuclear Science and Engineering, Massachusetts Institute of Technology, Cambridge, MA 02138, USA
Matteo Bucci*
Affiliation:
Department of Nuclear Science and Engineering, Massachusetts Institute of Technology, Cambridge, MA 02138, USA
*
†Email address for correspondence: mbucci@mit.edu

Abstract

Bubble growth, departure and sliding in low-pressure flow boiling has received considerable attention in the past. However, most applications of boiling heat transfer rely on high-pressure flow boiling, for which very little is known, as experimental data are scarce and very difficult to obtain. In this work, we conduct an experiment using high-resolution optical techniques. By combining backlit shadowgraphy and phase-detection imaging, we track bubble shape and physical footprint with high spatial ($6\,\mathrm {\mu }{\rm m}$) and temporal ($33\,\mathrm {\mu }{\rm s}$) resolutions, as well as bubble size and position as bubbles nucleate and slide on top of the heated surface. We show that at pressures above 1 MPa bubbles retain a spherical shape throughout the growth and sliding process. We analytically derive non-dimensional numbers to correlate bubble velocity and liquid velocity throughout the turbulent boundary layer and predict the sliding of bubbles on the surface, solely from physical properties and the bubble growth rate. We also show that these non-dimensional solutions can be leveraged to formulate elementary criteria that predict the effect of pressure and flow rate on bubble departure diameter and growth time.

Information

Type
JFM Papers
Copyright
© The Author(s), 2024. Published by Cambridge University Press
Figure 0

Figure 1.Summary of high-pressure bubble departure diameter data in the literature.

Figure 1

Figure 2.Longitudinal cross-sectional view of the test section and zoomed in view near the boiling surface to illustrate the optical measurement technique.

Figure 2

Table 1.Operating conditions under investigation and number of individual bubble histories tracked.

Figure 3

Figure 3.Phase-detection (PD) and shadowgraphy side view images of flow boiling at 0.2 MPa. The dashed orange line represents the location of a nucleation site. The solid blue line shows the vertical displacement of a bubble over time.

Figure 4

Figure 4.Phase-detection images of flow boiling at different pressures. The dashed orange line represents the location of a nucleation site. The solid blue line shows the vertical displacement of a bubble over time.

Figure 5

Figure 5.Bubble growth statistics (a,c,e) and selected histories (b,d,f) from 1 to 4 MPa at a mass flux of 500 kg m$^{-2}$ s$^{-1}$.

Figure 6

Figure 6.Bubble growth statistics (a,c,e) and selected histories (b,d,f) from 1 to 4 MPa at a mass flux of 1000 kg m$^{-2}$ s$^{-1}$.

Figure 7

Figure 7.Bubble growth statistics (a,c,e) and selected histories (b,d,f) from 1 to 4 MPa at the highest mass fluxes tested (2000 kg m$^{-2}$ s$^{-1}$ at 1 MPa and 1500 kg m$^{-2}$ s$^{-1}$ at 2–4 MPa).

Figure 8

Table 2.Summary of empirical $C_{{RB}}$ measurements and their comparison against theoretical predictions.

Figure 9

Figure 8.Schematic of a force balance on a single, sliding vapour bubble.

Figure 10

Figure 9.Experimentally measured bubble velocities and distances from wall across all operating conditions, with theoretical predictions overlayed.

Figure 11

Figure 10.Distance bubble travels (a,c,e) and forces acting on bubble (b,d,f) while sliding at a mass flux of 500 kg m$^{-2}$ s$^{-1}$.

Figure 12

Figure 11.Distance bubble travels (a,c,e) and forces acting on bubble (b,d,f) while sliding at a mass flux of 1000 kg m$^{-2}$ s$^{-1}$.

Figure 13

Figure 12.Distance bubble travels (a,c,e) and forces acting on bubble (b,d,f) while sliding at the highest mass fluxes tested (2000 kg m$^{-2}$ s$^{-1}$ at 1 MPa and 1500 kg m$^{-2}$ s$^{-1}$ for 2–4 MPa).

Figure 14

Figure 13.Proposed departure criterion illustrated with departure data at 1 MPa, with a mass flux and heat flux of 1000 kg m$^{-2}$ s$^{-1}$ and 500 kW m$^{-2}$, respectively. Note that the scales for the graph and images are different.

Figure 15

Figure 14.Departure diameter (a) and growth time (b) predictions as a function of pressure for various mass fluxes. Solid lines show predictions from (3.13), while the dashed lines show predictions from (3.29) and (3.30). For the sake of illustration, $C_{RB}=B/2$ and $q''=500$ kW m$^{-2}$.

Figure 16

Figure 15.Departure diameter (a) and growth time (b) predictions and measurements as a function of mass flux for various pressures.

Figure 17

Figure 16.Bubble columns appearing from two nucleation sites in $10\,^{\circ }{\rm C}$ subcooled flow boiling at 7.6 MPa with a mass flux and heat flux of 1000 kg m$^{-2}$ s$^{-1}$ and 220 kW m$^{-2}$, respectively.

Figure 18

Figure 17.Schematic of the flow boiling test facility.

Figure 19

Table 3.Uncertainty of measurements from high-pressure flow boiling test facility.

Figure 20

Figure 18.Flowchart for bubble tracking algorithm.

Figure 21

Figure 19.Illustration of the procedure used to correlate bubble positions between two consecutive frames.

Figure 22

Figure 20.Shadowgraph image of bubble on the surface (a) and the intensity profile of the image at the cross-section drawn through the middle of one bubble (b). Dashed red line in (a) indicates the position of the cross-section.

Figure 23

Figure 21.Bond, capillary and Weber numbers as a function of pressure at two different mass fluxes.

Figure 24

Figure 22.Cumulative distribution function of the measured bubble diameter in wall units (a) and bubble Reynolds number (b) at different operating pressures.

Figure 25

Figure 23.Drag coefficient comparison.

Figure 26

Figure 24.Sensitivity of drag coefficient and buoyancy to bubble sliding predictions.

Figure 27

Figure 25.Sensitivity of diameter averaging scheme to bubble departure diameter predictions.