Transcatheter pulmonary valve insertion, expanded use (beyond large conduits from the right ventricle to pulmonary artery), and future directions*

Published online by Cambridge University Press:  29 December 2014

Jeremy M. Ringewald*
Affiliation:
St Joseph’s Children’s Hospital Tampa, Tampa, Florida, United States of America
Elsa J. Suh
Affiliation:
St Joseph’s Children’s Hospital Tampa, Tampa, Florida, United States of America
*
Correspondence to: Dr J. M. Ringewald, MD, 3003 W. Dr MLK Jr. BLVD, St Joseph’s Children’s Hospital, 33607 Tampa, Florida, United States of America. E-mail: tampakidhrtdoc@gmail.com
Rights & Permissions [Opens in a new window]

Abstract

Transcatheter pulmonary valve insertion is the most important advance in congenital interventional cardiology since atrial septal defect devices became commonly available 15 years ago. It has changed the way we look at a number of diverse diagnoses and changes how we plan, diagnose, operate, and follow-up patients. It has changed how we counsel families expecting a child that may benefit from it. Expanded use of the Melody® valve, outside its United States Food and Drug Administration approved indications, has helped numerous additional patients. The use of transcatheter pulmonary valve insertion in selected patients following surgical Gore-tex® bileaflet in valve right ventricular outflow tract reconstruction and those with a history of prior small homograft conduits will be discussed.

Information

Type
Original Article
Copyright
© Cambridge University Press 2014 
Figure 0

Figure 1 Transoesophageal echocardiography (TOE) images from three different Gore-tex® bileaflet valve (GTBV) patients. The left panel demonstrates a transcatheter pulmonary valve insertion (TPVI) favourable stuck-open valve leaflet appearance. The middle panel arrow demonstrates complete dehiscence and absence of the anterior pulmonary valve leaflet, not a good TPVI candidate. The right panel arrows demonstrate large paravalvular leaks in both posterior and anterior pulmonary valve leaflets, also not a good TPVI candidate.

Figure 1

Figure 2 Top left, Gore-tex® bileaflet valve (GTBV) appearance of valve favourable for transcatheter pulmonary valve insertion (TPVI), thick and minimally mobile leaflets. Top middle, balloon sizing. Top right, pre-stent delivery. Bottom left, pre-stent holding GTBV open. Bottom middle, Melody delivery. Bottom right, competent new valve.

Figure 2

Figure 3 A 12 mm homograft conduit patient. Top left panel, pre-PA angiogram. Top middle, pre-lateral angiogram. Top right, balloon sizing with 18 mm balloon. Bottom left, post pre-stent. Bottom middle, valve delivery. Bottom right, post-valve.