Hostname: page-component-74656f9884-j7cmm Total loading time: 0 Render date: 2026-11-05T22:30:52.090Z Has data issue: false hasContentIssue false

Detection of pegylated epoetin β in horse plasma after intravenous administration

Published online by Cambridge University Press:  22 October 2009

D H Catlin*
Affiliation:
Anti-Doping Research Inc., 3873 Grand View Boulevard, Los Angeles, CA 90066, USA
G A Maylin
Affiliation:
Equine Drug Testing and Research Program, College of Veterinary Medicine, Cornell University, 925 Warren Drive, Ithaca, NY 14850, USA
S Benchaar
Affiliation:
Anti-Doping Research Inc., 3873 Grand View Boulevard, Los Angeles, CA 90066, USA
S M Neades
Affiliation:
Anti-Doping Research Inc., 3873 Grand View Boulevard, Los Angeles, CA 90066, USA
M S Timmons
Affiliation:
Anti-Doping Research Inc., 3873 Grand View Boulevard, Los Angeles, CA 90066, USA
K H McKeever
Affiliation:
Department of Animal Sciences, The Equine Science Center, Rutgers, The State University of New Jersey, 84 Lipman Drive, New Brunswick, NJ 08901-8525, USA
*
*Corresponding author: dcatlin@antidopingresearch.org

Abstract

Methoxy polyethylene glycol–epoetin β (pegylated epoetin β, peg-epoetin β, Mircera®) is an erythropoiesis-stimulating agent that is synthesized by pegylating epoetin β. It is prohibited in racehorses and humans because it enhances their performance. It is detectable in human urine and plasma using the isoelectric focusing–double-blotting (IEF–DB) method that has been widely applied in human doping control laboratories to detect doping with recombinant erythropoietins (EPOs). Fifty micrograms of peg-epoetin β were administered intravenously to a 450 kg female Thoroughbred, and blood was collected for 48 h. The plasma was processed by immunopurification followed by IEF–DB. The analytical procedures required about 2 days. No peg-epoetin β was detected in the baseline plasma collected prior to drug administration. It was readily detected in samples collected at 2, 4, 6, 8, 24 and 48 h. The isoforms showed a characteristic pattern that differed from epoetin β and was unlike any other known erythrocyte-stimulating agent or recombinant EPO. No peg-epoetin β was detected in plasma from five control horses. The plasma samples were also tested by a rapid, automated and chemiluminescent immunometric assay for EPO (Immulite®). The samples collected from the treated horse at 2–48 h contained the equivalent of approximately 200–800 pg ml− 1 of peg-epoetin β. The samples from the ten control horses were negative. These data show that a small dose of peg-epoetin β is detectable for 48 h by two different methods that are based on two different principles (chemiluminescence immunoassay and IEF–DB). The Immulite® assay is suitable as a screen and the IEF–DB assay as a confirmation method. These studies need to be expanded to other horses. The screen and confirmation tests, if applied, will probably eliminate the use of peg-epoetin β as a horse doping agent.

Information

Type
Short Communication
Copyright
Copyright © Cambridge University Press 2009
Figure 0

Fig. 1 Electropherogram showing isoelectric-focused patterns of standards and peg-epoetin β isolated from equine plasma with immunoaffinity chromatography. Lane 1, human urinary EPO standard; lanes 2 and 11, mixture of BRP standard (composed of epoetin α and epoetin β, appearing as the six bands in the basic region) and darbepoetin α standard (the four bands in the acidic region); lanes 3–9, plasma collected from horse treated with peg-epoetin β at 0 (baseline), 2, 4, 6, 8, 24 and 48 h; lane 10, peg-epoetin β standard. The most acidic band of peg-epoetin β is labelled band 1 (arrow) in lane 4

Figure 1

Fig. 2 Plasma peg-epoetin β concentrations determined by the Immulite® 1000 assay following a single intravenous injection of 50 μg to a horse. The standard curve is shown in the inset