Electron Beam Induced Impurity Electro-Migration in Unintentionally Doped GaN

Published online by Cambridge University Press:  13 June 2014

M. Toth
Affiliation:
Microstructural Analysis Unit, University of Technology, Sydney, PO Box 123, Broadway, NSW 2007, Australia, matthew.phillips@uts.edu.au
K. Fleischer
Affiliation:
On leave from Technical University of Berlin
M. R. Phillips
Affiliation:
Microstructural Analysis Unit, University of Technology, Sydney, PO Box 123, Broadway, NSW 2007, Australia, matthew.phillips@uts.edu.au

Abstract

Electron beam induced electromigration of ON + and H+ impurities in unintentionally n-doped GaN was investigated using cathodoluminescence (CL) kinetics profiling, CL imaging of regions pre-irradiated with a stationary electron beam, and wavelength dispersive x-ray spectrometry (WDS). The presented results (i) illustrate induced impurity diffusion in wide bandgap semiconductors, (ii) provide experimental evidence for the (VGa−ON)2− model of yellow luminescence in GaN with low Si content1 , (iii) confirm the roles of O in frequently reported bound exciton and donor-acceptor pair emissions and (iv) suggest the involvement of ON + and hydrogenated gallium vacancies in a blue emission in autodoped GaN.

Information

Type
Research Article
Copyright
Copyright © 1999 Materials Research Society
Figure 0

Figure 1.(a) CL spectra (Eb=15keV, corrected for system response) of autodoped GaN obtained at 4K (Ib=0.14nA, band pass=1nm) and 300K (inset, Ib=0.5nA, band pass=2.5nm). The high intensity of the second order peaks is a system response correction artifact. (b) Optical absorption spectra of 20, 30 and 40nm C films deposited under identical conditions.

Figure 1

Figure 2.Qualitative WDS analysis of autodoped GaN (spot mode, Eb=25keV, Ib=300nA). (a) raw WDS spectra showing the OKα and NKα lines before and after a 30min irradiation, (b) OKαand CKα kinetics profiles. Si was not detected in the sample.

Figure 2

Figure 3.CL kinetics (Eb=15keV) of (a) 3.4eV, BL and YL emissions at 300K (Ib=3nA) and (b) DX, DAP, BL and YL emissions at 4K (Ib=6nA). The inset in (a) shows detail of the first 10s of the 3.4eV emission obtained using a lower electron dose (Ib=1.2nA).

Figure 3

Figure 4.CL images (T=300K, Eb=15keV, Ib=0.8nA, horizontal field width = 95μm) of a region pre-irradiated in 4 places using a stationary electron beam. The images were acquired using the: (a) 3.4eV, (b) BL and (c) YL emissions. Each spot irradiation was performed for approximately 10min (Ib=5nA).

Figure 4

Figure 5.CL images (T=4K, Eb=15keV, Ib=0.2nA, horizontal field width = 42.5μm) of a region irradiated in spot mode (Ib=6nA) for 700s acquired using the: (a) DX, (b) DAP, (c) BL and (d) YL emissions.