Hostname: page-component-74656f9884-2dmjx Total loading time: 0 Render date: 2026-11-08T06:08:37.209Z Has data issue: false hasContentIssue false

Infrared signal of the lobed mixer with external air mixing

Published online by Cambridge University Press:  06 May 2021

S.M. Choi*
Affiliation:
Jeonbuk National University College of Engineering, Deokjin-Gu, Jeonju, Republic of Korea
H.S. Jang
Affiliation:
Jeonbuk National University College of Engineering, Deokjin-Gu, Jeonju, Republic of Korea
H.H. Park
Affiliation:
Hanwha Aerospace, Seongnam, Republic of Korea
Rights & Permissions [Opens in a new window]

Abstract

In order to know the characteristics of reducing the exhaust gas infrared signal of the lobed mixer according to the external air mixing ratio, an infrared signal and temperature distribution measurement using a micro-turbojet engine is performed. A certain amount of compressed air is supplied through an external duct mounted on the micro-turbojet engine exhaust to simulate bypass flow, which is mixed with high-temperature core air and ejected to the atmosphere. The exhaust nozzle used in the experiment is a lobed mixer with a lobe of sinusoidal shape and is designed to have a penetration of 0.2. Exhaust gas temperature and infrared signal are measured according to distance from nozzle outlet under conditions of bypass ratio of 0.5, 1.0 and 1.4. Infrared reduction rates are compared to data without compressed air supply. As a result of the experiment, as the bypass ratio increased, the infrared signal of the exhaust gas and the temperature decrease with bypass ratio increase, and in the case of a bypass ratio of 1.4, the effect of reducing the temperature is observed even at a long distance. In addition, we compared the results of previous studies of a simple cone shape without mixer with infrared reduction effect. The results show that the lobed mixer has a greater effect on reducing the temperature of the exhaust gas and reducing the infrared signal than the cone nozzle. The structure of the mixed jet flow is also studied through Schlieren visualisation and 3D temperature distribution.

Information

Type
Research Article
Copyright
© The Author(s), 2021. Published by Cambridge University Press on behalf of Royal Aeronautical Society
Figure 0

Figure 1. Olympus HP engine.

Figure 1

Table 1 Lobed mixer specifications

Figure 2

Figure 2. Side view of lobed mixer.

Figure 3

Figure 3. Layout of the lobed mixer (a) and front picture of the lobed mixer (b).

Figure 4

Figure 4. Micro-turbojet engine with lobed mixer (a) and side picture of lobed mixer (b).

Figure 5

Figure 5. Compressed air supply system.

Figure 6

Figure 6. Layout of compressed air supply system.

Figure 7

Figure 7. Layout of infrared measurement system.

Figure 8

Figure 8. Layout of X–Y traverse temperature measurement system.

Figure 9

Figure 9. Picture of plume temperature measurement system.

Figure 10

Figure 10. Picture of Schlieren visualisation system.

Figure 11

Figure 11. Layout of Schlieren visualisation system.

Figure 12

Figure 12. IR signature with bypass ratio: (a) bypass 0.0 (b) bypass 0.5 (c) bypass 1.0 (d) bypass 1.4.

Figure 13

Figure 13. IR reduction rate with distance.

Figure 14

Figure 14. 2D Temperature distribution with bypass ratio.

Figure 15

Figure 15. 3D Temperature distribution with bypass ratio: (a) bypass 0.0 (b) bypass 0.5 (c) bypass 1.0 (d) bypass 1.4.

Figure 16

Figure 16. Plume temperature distribution (bypass 0.5).

Figure 17

Figure 17. Plume temperature distribution (bypass 1.0).

Figure 18

Figure 18. Plume temperature distribution (bypass 1.4).

Figure 19

Figure 19. Temperature reduction rate with distance from nozzle exit.

Figure 20

Figure 20. Infrared reduction rate and delta temperature with bypass ratio.

Figure 21

Figure 21. Visualisation of plume flow with bypass ratio: (a) bypass 0.0 (b) bypass 0.5 (c) bypass 1.0 (d) bypass 1.4.