Lost needle in the oral cavity: can the nightmare be just a bad dream?

Published online by Cambridge University Press:  05 February 2024

Laura Rodríguez-Alcalá
Affiliation:
Department of Otorhinolaryngology, Hospital Quiron Salud Marbella and Hospital Quiron Salud Campo de Gibraltar, Spain
Johanna Ximena Valderrama-Penagos
Affiliation:
Department of Otorhinolaryngology, Hospital Quiron Salud Marbella and Hospital Quiron Salud Campo de Gibraltar, Spain
Ernesto O'Connor-Garcia St
Affiliation:
Medicine School, Universidad Rey Alfonso X, Madrid, Spain
Carlos O'Connor-Reina*
Affiliation:
Department of Otorhinolaryngology, Hospital Quiron Salud Marbella and Hospital Quiron Salud Campo de Gibraltar, Spain
*
Corresponding author: Carlos O'Connor-Reina; Email: Carlos.oconnor@quironsalud.es
Rights & Permissions [Opens in a new window]

Abstract

Objective

The loss of a scalpel or a needle during surgery can threaten the health of the patient and lead to additional costs, and radiographical assistance during surgery has been the only recovery method. This study evaluates the efficacy of a metal detector compared with conventional radiology for recovering a needle lost in the oropharynx during surgery.

Method

Different fragment sizes of needles normally used in pharyngoplasty were embedded at different locations and depths in a lamb's head. Three experienced and three junior otolaryngologists searched for the needle fragments using a metal detector and conventional radiology.

Results

All fragments were found with each method, but the mean searching time was 90 per cent shorter with the metal detector.

Conclusion

A metal detector can be a useful tool for locating needles that break during ENT surgery, as it requires less time than conventional radiology and avoids exposing patients to radiation.

Information

Type
Clinical Records
Copyright
Copyright © The Author(s), 2024. Published by Cambridge University Press on behalf of J.L.O. (1984) LIMITED
Figure 0

Table 1. Factors associated with needles lost during surgery

Figure 1

Figure 1. High-sensitivity metal detector (model IP-68; Inkbird Plus, Shenzhen, China).

Figure 2

Figure 2. Different sizes of surgical needle fragments are weighed on a digital scale.

Figure 3

Figure 3. Depth measurement with a digital tyre gauge.

Figure 4

Figure 4. X-ray of a lamb's head with a surgical needle fragment in its tongue.

Figure 5

Table 2. Junior surgeons using metal detector for needle fragment detection

Figure 6

Table 3. Experienced surgeons using metal detector for needle fragment detection

Figure 7

Table 4. Junior surgeons using X-ray for needle fragment detection

Figure 8

Table 5. Experienced surgeons using X-ray for needle fragment detection

Figure 9

Table 6. Time taken for junior surgeons to detect needle fragments and significance level between techniques

Figure 10

Table 7. Time taken for experienced surgeons to detect needle fragments and significance level between techniques

Supplementary material: File

Rodríguez-Alcalá et al. supplementary material

Rodríguez-Alcalá et al. supplementary material
Download Rodríguez-Alcalá et al. supplementary material(File)
File 15.1 MB