The spatial and temporal effect of electrochromic windows on indoor and human microbiome in an inpatient hospital

Published online by Cambridge University Press:  25 October 2024

Man In Lam
Affiliation:
Faculty of Applied Science, School of Engineering, University of British Columbia, Kelowna, BC, Canada
Kelsey Gleason
Affiliation:
Department of Biomedical and Health Sciences, University of Vermont, Burlington, VT, USA
Allen B. Repp
Affiliation:
Department of Medicine, The Larner College of Medicine at the University of Vermont, Burlington, VT, USA
Sam Yeo
Affiliation:
Faculty of Applied Science, School of Engineering, University of British Columbia, Kelowna, BC, Canada
Kinga Vojnits
Affiliation:
Faculty of Applied Science, School of Engineering, University of British Columbia, Kelowna, BC, Canada
Piers MacNaughton
Affiliation:
Department of Environmental Health, Harvard T.H. Chan School of Public Health, Boston, MA, USA
Sepideh Pakpour*
Affiliation:
Faculty of Applied Science, School of Engineering, University of British Columbia, Kelowna, BC, Canada
*
Corresponding author: Sepideh Pakpour; Email: sepideh.pakpour@ubc.ca

Abstract

Objective:

Improving the hospital environment and developing novel disinfection strategies are critical for infection control in healthcare settings. In this study, we explored the effects of electrochromic (EC) windows on indoor and patient microbiome in an inpatient hospital.

Patient and setting:

Hematology-Oncology patients at the University of Vermont Medical Center

Methods:

We conducted a prospective study in ten occupied patient rooms. Five of the patient rooms had active EC windows that tint dynamically to control for heat and glare, and the other five rooms had deactivated EC windows that simulated traditional windows and blinds. Samples were collected one day before patient admission as baseline and on the 1st, 3rd, and 5th day of the patient stay. Total bacterial abundance and bacterial community structure were determined through quantitative PCR and 16s rRNA Illumina MiSeq sequencing, respectively.

Results:

Patient rooms with active EC windows had significantly lower light intensity and temperature than traditional patient rooms with blinds. The absolute bacterial abundance and diversities on windows were significantly lower in rooms with EC windows and the bacterial composition changed after one day EC window activation. Compared to baseline, relative abundance of the Staphylococcus genus was significantly lower on EC window surface during the five-day experiment. In contrast, the air microbiome was more diverse in rooms with EC windows.

Conclusion:

Active electrochromic (EC) windows in patient rooms result in lower light intensity and temperature, reduced bacterial abundance and diversities on window surfaces, and a more diverse air microbiome, informing future healthcare design.

Information

Type
Original Article
Creative Commons
Creative Common License - CCCreative Common License - BY
This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution and reproduction, provided the original article is properly cited.
Copyright
© The Author(s), 2024. Published by Cambridge University Press on behalf of The Society for Healthcare Epidemiology of America
Figure 0

Figure 1.Environmental conditions in Regular Rooms (gray) and EC Window Rooms (blue). (a) Box plots of light intensity, temperature, relative humidity (RH), CO2, and PM2.5 concentration. Data show the mean ± SEM. Statistical analysis compared results between Regular Rooms and EC Window Rooms (*, P < 0.05; **, P < 0.01; ***, P < 0.001). (b) Line graph of environmental conditions from T0 to T3. Data show mean ± SEM.

Figure 1

Figure 2.Bacteria source tracking analysis estimated the relative contribution of patient microbiome as sources for indoor environment microbiome. (a) Relative contribution of patient’s microbiome as sources for window sample’s microbiome at T0 on the left and at T3 on the right. Pie chart shows the proportion of patient’s palm microbiome in blue, saliva microbiome in brown, and unknown microbiome in white. (b) Relative contribution of patient’s microbiome as sources for blind microbiome at T0 (left) and at T3 (right). (c) Relative contribution of patients’ microbiome as sources for air sample’s microbiome at T0 (left) and at T3 (right).

Figure 2

Figure 3.Association between window types and the absolute bacterial abundance of indoor environment samples. Box plots show the copies of 16s rRNA genes found in window, air duct, air sample and blinds. Data show the mean ± SEM. The Regular Room group is shown in gray, and the EC Window Room group is shown in blue. Dashed line shows the LOD of qPCR (35 copies of genes). Statistical analysis compared results between Regular Rooms and EC Window Rooms (*, P < 0.05; **, P < 0.01; ***, P < 0.001).

Figure 3

Figure 4.Association between window types and the microbial diversity and community composition on indoor environmental samples. (a) Alpha diversity of environmental samples. Boxplots show the Shannon indices of window, air duct, air, and blinds samples. Data show the mean ± SEM. The Regular Room group is shown in gray, and the EC Window Room group is shown in blue. Statistical analysis compared results between Regular Room and EC Window Room (*, P < 0.05; **, P < 0.01; ***, P < 0.001). (b) Principal coordinates analysis (PCoA) of beta diversity of window samples at T0 based on weighted UniFrac dissimilarities. Regular Room is colored in red, and EC Window Room is colored in green. Significance is determined by permutational multivariate analysis of variance (PERMANOVA) with 999 permutations for room type and denoted at the corner of each PCoA (*, P < 0.05; **, P < 0.01; ***, P < 0.001). (c) PCoA of beta diversity of window samples at T1 and T3 based on weighted UniFrac dissimilarities. Ellipses are drawn at 95% confidence intervals for each room type. (d) PCoA of beta diversity of air samples at T1 and T3 based on weighted UniFrac dissimilarities.

Figure 4

Figure 5.(a) Relative abundance of Staphylococcus in indoor environment samples at T0, T1 and T3. The Regular Room group is shown on the left and the EC Window Room group is shown on the right. Window is shown in blue; air duct is shown in yellow; air sample is shown in red, and blind is shown in gray. Boxplots show the mean ± SEM. Statistical analysis compared results between T0 to T1 and to T3 separately (*, P < 0.05; **, P < 0.01; ***, P < 0.001). (b) Relative abundance of Pseudomonas in indoor environment samples. Boxplots show the mean ± SEM.

Figure 5

Figure 6.Association between window types and patient microbiome. (a) Box plots show the absolute bacterial abundance of patient’s palm (left) and saliva (right) samples at T1 and T3. The Regular Room group is shown in gray, and the EC Window Room group is shown in blue. Data show the mean ± SEM. Line graph shows the changes of absolute bacterial abundance of individual patient samples from T1 to T3. (b) Shannon diversity of palm (left) and saliva (right) samples at T1 and T3. (c) Relative abundance of Staphylococcus in palm (left) and saliva (right) samples at T1 and T3. (d) Relative abundance of Pseudomonas in palm (left) and saliva (right) samples at T1 and T3.

Figure 6

Figure 7.Illustration of indoor daylight through an EC Window (top) and traditional window with blinds (bottom) in a hospital. Occupants and indoor microbiome interact in both directions, which could contain beneficial microbiome (green) and pathogens (red). Bringing more daylight into buildings using an EC window (top) may reduce pathogen growth.

Supplementary material: File

Lam et al. supplementary material

Lam et al. supplementary material
Download Lam et al. supplementary material(File)
File 9.8 MB