Hostname: page-component-74656f9884-rdgjk Total loading time: 0 Render date: 2026-11-07T10:23:33.171Z Has data issue: false hasContentIssue false

Developments toward hard X-ray radiography on heavy-ion heated dense plasmas

Published online by Cambridge University Press:  28 October 2014

K. Li
Affiliation:
ExtreMe Matter Institute, GSI, Darmstadt, Germany Frankfurt Institute for Advanced Studies, Frankfurt am Main, Germany Joint Laboratory on High Power Laser and Physics, SIOM, Shanghai, China
B. Borm
Affiliation:
Goethe-Universität, Frankfurt am Main, Germany
F. Hug
Affiliation:
Institut für Kernphysik,TU Darmstadt, Darmstadt, Germany
D. Khaghani
Affiliation:
ExtreMe Matter Institute, GSI, Darmstadt, Germany Frankfurt Institute for Advanced Studies, Frankfurt am Main, Germany
B. Löher
Affiliation:
ExtreMe Matter Institute, GSI, Darmstadt, Germany Frankfurt Institute for Advanced Studies, Frankfurt am Main, Germany
D. Savran
Affiliation:
ExtreMe Matter Institute, GSI, Darmstadt, Germany Frankfurt Institute for Advanced Studies, Frankfurt am Main, Germany
N. A. Tahir
Affiliation:
GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt, Germany
P. Neumayer*
Affiliation:
ExtreMe Matter Institute, GSI, Darmstadt, Germany Frankfurt Institute for Advanced Studies, Frankfurt am Main, Germany
*
Address correspondence and reprint requests to: P. Neumayer, ExtreMe Matter Institute, GSI, Planckstr. 1, 64291 Darmstadt, Germany. E-mail: p.neumayer@gsi.de

Abstract

We have studied the potential of hard X-ray radiography as a diagnostic in high energy density experiments, proposed for the future Facility for Antiproton and Ion Research (FAIR). We present synthetic radiographic images generated from hydrodynamic simulations of the target evolution. The results suggest that high-resolution density measurements can be obtained from powerful hard X-ray sources driven by a PW-class high-energy laser system. Test measurements of a prototype hard X-ray imaging detector for photon energies above 100 keV are presented.

Information

Type
Research Article
Copyright
Copyright © Cambridge University Press 2014 
Figure 0

Fig. 1. (a) Schematic setup to perform laser-driven X-ray radiography on a heavy-ion heated sample. (b) Calculated bremsstrahlung emission spectrum (blue, solid) generated in the backlighter foil by the laser-generated supra-thermal electrons, and cumulated radiated energy (blue, dot-dashed). For comparison, the transmission through 1 mm of lead is plotted (black).

Figure 1

Fig. 2. Attenuation (dot-dashed) and fraction of deposited energy (solid line) within the sensitive layer, for SR-type imaging plate (red) and DRZ screen (blue), determined from Monte-Carlo calculations with GEANT4. Again, the transmission through 1 mm lead is shown (black).

Figure 2

Table 1. Detector parameters as used in the Monte-Carlo simulations for quantum efficiency and response

Figure 3

Fig. 3. Synthetic radiographs from various stages of a heavy-ion heated target (a–c), see text), and calibration wedge (d). The X-ray spectrum from Figure 1b was used with a total energy of 40 J in the hot electron distribution. Upper images assume an image plate detector, lower images using the DRZ-screen show improved signal-to-noise due to the increased quantum efficiency.

Figure 4

Fig. 4. Schematic of the prototype hard X-ray imager (details see text).

Figure 5

Fig. 5. Radiographs obtained with the hard X-ray imager at the S-DALINAC electron accelerator (a, b) and at the PHELIX laser facility (c). The test objects are tantalum blocks of various thicknesses (a), M10 steel screw (b), and M4 steel nut and tantalum slabs (c).