A physically based method for correcting temperature profile measurements made using thermocouples

Published online by Cambridge University Press:  08 September 2017

L. Maclagan Cathles IV
Affiliation:
Department of Geophysical Sciences, University of Chicago, 5734 South Ellis Avenue, Chicago, Illinois 60637, USA E-mail: mcathles@uchicago.eduDepartment of Earth and Atmospheric Sciences, Cornell University, 2134 Snee Hall, Ithaca, New York 14883, USA
L.M. Cathles III
Affiliation:
Department of Earth and Atmospheric Sciences, Cornell University, 2134 Snee Hall, Ithaca, New York 14883, USA
M.R. Albert
Affiliation:
US Army Cold Regions Research and Engineering Laboratory, 72 Lyme Road, Hanover, New Hampshire 03755-1290, USA
Rights & Permissions [Opens in a new window]

Abstract

High-frequency (diurnal) temperature variations occur simultaneously at multiple depths separated by meters of snow in at least several and probably many Arctic and Antarctic thermocouple datasets. These temperature variations cannot be caused by heat conduction from the surface because their amplitudes are too large and there is no phase lag with depth, and they cannot be caused by heat advection because the air flux required is greater than is available. Rather, the simultaneous temperature variations (STVs) appear to originate within the box that houses the data logger as thermocouple-like offset voltages, wire heating or thermistor error. The STVs can be corrected by requiring that the temperatures vary smoothly with time at the greatest depth at which temperature is measured. The correction voltage determined in this fashion, when applied to the thermocouples at other depths, corrects the entire dataset. The method successfully removes STVs with 24 hour period that are up to 3.8°C in amplitude, and is superior to the averaging techniques commonly used to correct thermocouple data because it introduces no spurious (non-physical) temperature variations. The correction method described can be applied to all thermocouple data where temperature measurements have been made at depths > ~0.5 m into the snowpack. The corrections should allow more physical process and parameter information to be extracted more confidently from existing firn temperature data. Identification of the STVs and their probable cause also suggests how better data might be collected in the future.

Information

Type
Instruments and Methods
Copyright
Copyright © International Glaciological Society 2007
Figure 0

Fig. 1.(a) Measured thermocouple data from the surface (gray dots), 0.5 m depth (gray curve with black squares), 1.0 m depth (black curve with black circles), 1.5 m depth (gray curve with black diamonds) and the reference temperature (black dots) within the unperturbed snowpack in Summit, Greenland, between 20 March and 30 April 2004. The daily variations decrease with depth to ~0.25 m depth and show little change at depths greater than 0.25 m. The deep temperature variations are sometimes anticorrelated (b) and at other times correlated (d) with the surface temperature. Daily changes at 1.5 m can reach 3.8°C (c). (b) and (c) have the same temperature scales on the vertical axis.

Figure 1

Fig. 2.Schematic of data logger and thermocouples. J1–J3 indicate wire junctions where Seebeck-effect voltage offsets occur.

Figure 2

Fig. 3.Simultaneous temperature variations in Greenland Climate Network’s raw data from the Summit AWS. The magnitude of the STVs is ten times less then in Figure 1.

Figure 3

Fig. 4.Measured thermocouple temperatures (10 min average) at 1.5 m depth (small gray points). Measurements when the data-logger thermistor reference temperature was between -30 and -33°C are indicated by black points. The solid curve is a best-fit (ninth-order) polynomial regression through the black points.

Figure 4

Fig. 5.STVs in Siple Dome data are only present in the latter half of the time series, when the reference temperature (thick gray curve) begins to decrease and show larger temporal variations. The data at 4 and 6.15 m depth are indicated by a thin black curve and thin gray curve respectively. The data used to fit the ninth-order polynomial that defines the smooth variation in temperature at 6.15 m depth are indicated by black points.

Figure 5

Fig. 6.(a) Corrected thermocouple data from the surface (gray dots), 0.5 m depth (gray curve with black squares), 1.0 m depth (black curve with black circles), 1.5 m depth (gray curve with black diamonds) and the reference temperature (black dots) within the unperturbed snowpack in Summit, Greenland, between 20 March and 30 April 2004. Cf. Figure 1.

Figure 6

Fig. 7.Siple Dome measured (gray) and corrected (black) data at 4 and 6.15 m depth.

Figure 7

Fig. 8.(a) Voltage correction as a function of reference temperature for the Greenland data we collected. (b) Voltage correction as a function of reference temperature for Siple Dome data. (c) Measured voltage offset as a function of reference temperature for laboratory measurements. Note the hysteresis in (b) and (c). In each successive plot, the voltage correction/offset is about an order of magnitude less than in the previous plot. This is partly because the data loggers at Siple Dome and in the laboratory did not reach temperatures as low as the data logger at Summit Greenland.

Figure 8

Fig. 9.Corrected (solid black curve) and uncorrected (light-gray dots) thermocouple data at 1.5 m depth for our Greenland dataset. Averaging the measured data over 24 hours (gray connected triangles) or applying a 5 day running mean (black connected circles) produces fictitious temperature variations with 0.2–0.5°C amplitude and ~9 day period.