Hostname: page-component-74656f9884-6grmk Total loading time: 0 Render date: 2026-11-06T01:57:15.336Z Has data issue: false hasContentIssue false

Re-adjustments for MOM calculations of microstrip and stripline power dissipation

Published online by Cambridge University Press:  30 July 2020

Frederick Huang*
Affiliation:
Department of Electronic, Electrical and Systems Engineering, University of Birmingham, Edgbaston, Birmingham, B15 2TT, UK
*
Author for correspondence: F. Huang, E-mail: f.huang@bham.ac.uk
Rights & Permissions [Opens in a new window]

Abstract

Microstrip and stripline losses in Method of Moments (MOM) calculations have an error arising from the large current density at the strip edges, characterized by an integration limit (W/2-d) in the equation for current density in thin strips (width W), where d is a fitting parameter. It depends primarily on the width of the MOM subsection on the edge of the strip. By comparing with the integration limit (W/2-Δ) for an actual strip with finite thickness, a correction factor is estimated. The equations incorporating d are confirmed by comparing with MOM calculations of isolated stripline, uniformly spaced parallel strips, striplines and microstrips close to ground planes, and with a strip in a uniform, externally applied magnetic field. The results are also consistent with measurements with copper. This makes the accuracy of the loss estimates commensurate with the excellence of the other aspects of MOM simulations.

Information

Type
EM Field Theory
Copyright
Copyright © Cambridge University Press and the European Microwave Association 2020
Figure 0

Fig. 1. Fitting parameters: integration limits Δand d for (respectively): (a) strip with finite thickness, and (b) MOM calculation with a zero-thickness conductor.

Figure 1

Fig. 2. Current crowding factor: approximate equation (10) compared with MOM calculations (9). For strips carrying a known current. (a) For sub-sectioning X1:X2:X3:X4 = 1:2:4:8 : typical values of X1/W for copper and superconductor are given. Red and dashed black lines correspond to the similar lines in Fig. 1. (b) For various values of X1:X2:X3:X4; with the approximate equation subtracted. For 1:1:1:1, m is irrelevant, so the value shown on the graph is arbitrary. (c) Comparison of sub-sectioning: X1:X2:X3:X4 = 1:2:4:8 and x1:x2:x3:x4 = 1:6:12:24.

Figure 2

Fig. 3. Resonators used in simulations: one spiral and the other including a meander line, used separately or together.

Figure 3

Fig. 4. Current crowding factor estimated from the approximate equation compared with MOM calculations: externally applied uniform magnetic field. (Legend as in Fig. 2(a).) Red and dashed black lines correspond to the similarly-colored lines in Fig. 1.

Figure 4

Fig. 5. Current crowding factor for very thin microstrips and striplines, with nearby ground planes, based on MOM (Sonnet) calculations.

Figure 5

Fig. 6. Current crowding factor for very thick microstrips with nearby ground planes, based on MOM (Sonnet) calculations, t/2δ = 16, compared with the thin-layer simulations.

Figure 6

Fig. 7. Current crowding factor for t/2δ of the order of 1, compared with thin layers.

Figure 7

Fig. 8. Current crowding factor for a thin resistive isolated 100 μm wide stripline, based on MOM (Sonnet) calculations.

Figure 8

Fig. 9. Hairpin filter with 22% bandwidth and 1 GHz center frequency. (a) Layout, (b) simulated frequency response for various loss mechanisms, and measured response.

Figure 9

Fig. 10. Losses: measurements compared with computations for microstrip (h ≫ W) and strips with near neighbors; scaled so that the un-corrected resistive loss (X1/W = 0.25) is 1 unit.

Figure 10

Fig. 11. Resonator to measure losses: (a) precursor: dual spiral resonator. (b) spiral-in-spiral-out resonator. (c) Response.

Figure 11

Fig. 12. Conformal mappings for stripline. (a) An isolated strip, or parallel strips with all currents in the same direction. (b) Parallel strips with current directions alternating. (c) An isolated strip in an externally applied uniform field. (d) Parallel strips in an external field.

Figure 12

Table 1. Conformal mappings for current crowding factor ηd

Figure 13

Fig. 13. Method of moments calculation using piecewise constant approximations (rectangular functions). (a) Magnetic flux φpqin a zone PQ due to a current I. (b) Current distribution in a stripline carrying a current. (c) Current distribution in a stripline in an externally applied uniform field.

Figure 14

Fig. 14. Approximating a uniform field in simulations: l = 80 μm, W = 40 μm, and the cubical cavity has side 2000 μm.