Hostname: page-component-7b7567c8c-fvjsw Total loading time: 0 Render date: 2026-11-14T22:46:40.148Z Has data issue: false hasContentIssue false

Comparison of two electronic hand hygiene systems using real-time feedback via wireless technology to improve hand hygiene compliance in an intensive care unit

Published online by Cambridge University Press:  25 July 2022

José R. Generoso Jr
Affiliation:
Instituto Israelita de Ensino e Pesquisa Albert Einstein, Hospital Israelita Albert Einstein, São Paulo, São Paulo, Brazil
Eduardo Casaroto
Affiliation:
Instituto Israelita de Ensino e Pesquisa Albert Einstein, Hospital Israelita Albert Einstein, São Paulo, São Paulo, Brazil
Ary Serpa Neto
Affiliation:
Instituto Israelita de Ensino e Pesquisa Albert Einstein, Hospital Israelita Albert Einstein, São Paulo, São Paulo, BrazilMonash University, ANZIC-RC, Melbourne, New South Wales, Australia
Marcelo Prado
Affiliation:
Universidade de São Paulo, São Carlos, São Paulo, Brazil
Guilherme M. Gagliardi
Affiliation:
Universidade de São Paulo, São Carlos, São Paulo, Brazil
Fernando Gatti de Menezes
Affiliation:
Infection Control Unit, Hospital Israelita Albert Einstein, São Paulo, São Paulo, Brazil
Priscila Gonçalves
Affiliation:
Infection Control Unit, Hospital Israelita Albert Einstein, São Paulo, São Paulo, Brazil
Fábio Barlem Hohmann
Affiliation:
Instituto Israelita de Ensino e Pesquisa Albert Einstein, Hospital Israelita Albert Einstein, São Paulo, São Paulo, Brazil
Guilherme Benfatti Olivato
Affiliation:
Instituto Israelita de Ensino e Pesquisa Albert Einstein, Hospital Israelita Albert Einstein, São Paulo, São Paulo, Brazil
Gustavo Potratz Gonçalves
Affiliation:
Instituto Israelita de Ensino e Pesquisa Albert Einstein, Hospital Israelita Albert Einstein, São Paulo, São Paulo, Brazil
Andréa Marques Pereira
Affiliation:
Instituto Israelita de Ensino e Pesquisa Albert Einstein, Hospital Israelita Albert Einstein, São Paulo, São Paulo, Brazil
Nathalia Xavier
Affiliation:
Instituto Israelita de Ensino e Pesquisa Albert Einstein, Hospital Israelita Albert Einstein, São Paulo, São Paulo, Brazil
Marcelo Fernandes Miguel
Affiliation:
Instituto Israelita de Ensino e Pesquisa Albert Einstein, Hospital Israelita Albert Einstein, São Paulo, São Paulo, Brazil
Elivane da Silva Victor
Affiliation:
Instituto Israelita de Ensino e Pesquisa Albert Einstein, Hospital Israelita Albert Einstein, São Paulo, São Paulo, Brazil
Michael B. Edmond
Affiliation:
West Virginia University School of Medicine, Morgantown, West Virginia, United States
Alexandre R. Marra*
Affiliation:
Instituto Israelita de Ensino e Pesquisa Albert Einstein, Hospital Israelita Albert Einstein, São Paulo, São Paulo, BrazilDepartment of Internal Medicine, University of Iowa Carver College of Medicine, Iowa City, Iowa, United States
*
Author for correspondence: Alexandre R. Marra, MD, MSc, PhD, University of Iowa Hospitals and Clinics, C51 GH, 200 Hawkins Drive, Iowa City, IA 52242. E-mail: alexandre-rodriguesmarra@uiowa.edu

Abstract

Background:

Most hand hygiene (HH) intervention studies use a quasi-experimental design, are primarily uncontrolled before-and-after studies, or are controlled before-and-after studies with a nonequivalent control group. Well-funded studies with improved designs and HH interventions are needed.

Objectives:

To evaluate healthcare worker (HCW) HH compliance with alcohol-based hand rub (ABHR) through direct observation (human observer), 2 electronic technologies, a radio frequency identification (RFID) badge system, and an invasive device sensor.

Methods:

In our controlled experimental study, 2,269 observations were made over a 6-month period from July 1 to December 30, 2020, in a 4-bed intensive care unit. We compared HH compliance between a basic feedback loop system with RFID badges and an enhanced feedback loop system that utilized sensors on invasive devices.

Results:

Real-time feedback by wireless technology connected to a patient’s invasive device (enhanced feedback loop) resulted in a significant increase in HH compliance (69.5% in the enhanced group vs 59.1% in the basic group; P = .0001).

Conclusion:

An enhanced feedback loop system connected to invasive devices, providing real-time alerts to HCWs, is effective in improving HH compliance.

Information

Type
Original Article
Creative Commons
Creative Common License - CCCreative Common License - BY
This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution and reproduction, provided the original article is properly cited.
Copyright
© The Author(s), 2022. Published by Cambridge University Press on behalf of The Society for Healthcare Epidemiology of America
Figure 0

Fig. 1.Real-time feedback loop system for hand hygiene monitoring. *Adapted from Marra and Edmond.20

Figure 1

Fig. 2.Differences between the devices installed in the ICU rooms. Rooms 3 and 4 have the invasive device sensor, which was not present in rooms 1 and 2 where only the feedback loop system was installed.

Figure 2

Fig. 3.Invasive device sensor flashing the green light when HCW manipulates the invasive device.

Figure 3

Fig. 4.Invasive device sensor connection to the IV bag on a pump.

Figure 4

Table 1.Hand Hygiene Direct Observations in the Control Group (Rooms 1 and 2) and the Interventional Group (Rooms 3 and 4)