Hostname: page-component-7b7567c8c-2n9c9 Total loading time: 0 Render date: 2026-11-17T02:00:40.604Z Has data issue: false hasContentIssue false

RBS Lattice Site Location and Damage Recovery Studies in GaN

Published online by Cambridge University Press:  13 June 2014

E. Alves
Affiliation:
ITN, Sacavém, Portugal
M.F. DaSilva
Affiliation:
ITN, Sacavém, Portugal
J.C. Soares
Affiliation:
ITN, Sacavém, Portugal
J. Bartels
Affiliation:
ISKP, University of Bonn, D-53115 Bonn, Germany, vianden@iskp.uni-bonn.de
R. Vianden
Affiliation:
ISKP, University of Bonn, D-53115 Bonn, Germany, vianden@iskp.uni-bonn.de
C.R. Abernathy
Affiliation:
Dept. Materials Science and Engineering, University of Florida, Gainesville, FL, USA
S.J. Pearton
Affiliation:
Dept. Materials Science and Engineering, University of Florida, Gainesville, FL, USA

Abstract

Erbium was implanted with 160 keV at doses between 5×1014 and 5×1015 at/cm2 into (0001) epitaxial GaN on sapphire and annealed at various temperatures between 600° and 1000° C. The RBS/Channeling technique was used to analyze the damage recovery during different annealing steps and to determine the lattice location of the implanted Er. For a sample implanted with 5×1014 and annealed for 30 min at 600° C a complete overlap of the Er and Ga angular scans across the <0001> axis was observed, indicating that 100% of Er occupies substitutional sites. Measurements along the <10 1> channel show that Er is located on Ga sites. The damage recovery was slightly better for the samples co-implanted with the same dose of Oxygen in an overlapping profile (E=25 keV). However, a complete recovery of the damage caused by the implantation was not achieved. Samples implanted with higher Er and O doses (5×1015 at/cm2 ) and at the same energies as above were annealed at 600° for 30 min and at 900°, 1000° C for 120 s using a proximity cap. The higher dose caused an almost complete amorphisation of the surface layer. After annealing indications of epitaxial regrowth were observed, however, the substitutional fraction remains substantially lower and the damage recovery is less complete.

Information

Type
Research Article
Copyright
Copyright © 1999 Materials Research Society
Figure 0

Figure 1:Random and <0001> aligned RBS spectra for GaN samples implanted with two different doses of Er ions after annealing at different temperatures. a) D = 5×1014 Er+/cm2, b) D = 5×1015 Er+/cm2

Figure 1

Figure 2:Angular scan through the <0001> axis of the GaN wurtzite lattice for a sample (Univ. Florida) implanted with Er and O at a dose of 5×1014 cm−2 each and annealed at 600° C for 30 min.

Figure 2

Figure 3:Projections of the atomic position of Ga and N in the GaN wurtzite lattice as seen along the <0001> and the <10 1> axes.

Figure 3

Figure 4:Angular scan through the <10 1> axis for the sample implanted with 5×1014 cm−2 Er+O after annealing at 900°C. The dotted and the dash-dotted curve are the angular scans expected for Ga and N, respectively. The symbols are the data points obtained for Er and Ga and the solid line represents the result of a simulation assuming 70% of the Er impurities in substitutional Ga positions.