Hostname: page-component-74656f9884-8r8nv Total loading time: 0 Render date: 2026-11-07T03:21:10.013Z Has data issue: false hasContentIssue false

Two-frequency undulator usage in compact self-amplified spontaneous emission free electron laser in Roentgen range

Published online by Cambridge University Press:  12 April 2017

K. Zhukovsky*
Affiliation:
Faculty of Physics, M.V. Lomonosov Moscow State University, Leninskie Gory, Moscow, 119991, Russia
I. Potapov
Affiliation:
Faculty of Physics, M.V. Lomonosov Moscow State University, Leninskie Gory, Moscow, 119991, Russia
*
Address correspondence and reprint requests to: K. Zhukovsky, Faculty of Physics, M.V. Lomonosov Moscow State University, Leninskie Gory, Moscow, 119991, Russia. E-mail: zhukovsk@physics.msu.ru

Abstract

The generation of harmonics in two-frequency undulator in a self-amplified spontaneous emission free electron laser (SASE FEL) is studied in order to produce Roentgen radiation in a relatively compact sized installation. The dynamics of SASE FEL is analyzed with the help of the phenomenological model to obtain the maximum of the X-ray high-harmonic power. The model accounts for the properties of the undulator magnetic field and of the electron beam and includes the major sources of losses, such as the electron energy spread, etc. It is compared and calibrated with the existing data on a FEL experiment. The advantages of the two-frequency undulator for Roentgen SASE FEL are demonstrated and the possibility to generate powerful mild Roentgen radiation at already ~25 m length is shown. The evolution of the bunching coefficients for high harmonics is studied together with the evolution of the FEL-induced energy spread. The linear and non-linear regimes are explored for common and for two-frequency undulators The usage of the two-frequency undulator for cascade SASE FEL with high X-ray harmonic power and high-harmonic bunching coefficients with low-induced energy spread is proposed.

Information

Type
Research Article
Copyright
Copyright © Cambridge University Press 2017 
Figure 0

Fig. 1. Function η(με,n) – blue line for v = 0.9, w = 1.062 (see. (17)). Previously used function – red line for v = w = 1.

Figure 1

Fig. 2. Simulation of FEL dynamics in phenomenological SASE FEL model: continuous lines, marked by arrows, n = 1 – red line, n = 3 – green line; numerical simulations results (as reported in Giannessi et al. (2011)): n = 1 – continuous lines, n = 3 – dashed lines; experimental data: n = 1 – circles, n = 3 – triangles.

Figure 2

Fig. 3. Evolution of the SASE FEL harmonic power with the two-frequency planar undulator with с k = 2.133, h = 3, d = −0.5 (left) and with the common planar undulator with d = 0 (right). The harmonic frequencies for the two-frequency undulator are λ1 = 20.5816 nm, λ3 = 6.86053 nm, λ5 = 4.11632 nm (left) and for the common undulator: λ1 = 20.192 nm, λ3 = 6.73066 nm, λ5 = 4.03839 nm (right). The values of the parameters of the undulator and of the beam: λu = 0.028 m, γ = 1506.85, PE = 103.95 GW, J = 9.96573 × 109 A/m2, I0 = 135 A, Σebeam = 4.31362 × 10−9 m2, σε = 0.0005. The harmonics are denoted as follows: n = 1 – red line, n = 3 – green line, n = 5 – blue line.

Figure 3

Fig. 4. Evolution of first three odd harmonics along the SASE FEL length (in meters) for the SASE FEL with k = 2.133, λu = 0.028, Ls = 67.2624 m, N = 2402, Lgain = 3.0431 m, γ = 3315.07, PE = 207.9 GW, J = 9.96573 × 109 A/m2, Σebeam = 3.92147 × 10−9 m2, I0 = 122.73 A, ζ = 1.1, σe = 0.0005, λ1 = 4.17189 nm, λ3 = 1.39063 nm.

Figure 4

Fig. 5. SASE FEL harmonic power evolution with the two-frequency undulator: n = 1 – red line, n = 3 – green line, n = 5 – blue line. The parameters are as follows: k = 2.133, h = 3, d = −0.5, λu = 0.028 m, γ = 1506.85, PE = 103.95 GW, J = 9.96573 × 109 A/m2, Σebeam = 4.31362 × 10−9 m2, λ1 = 20.5816 nm, λ3 = 6.86053 nm, λ5 = 4.11632 nm, σε = 0.0001.

Figure 5

Fig. 6. Evolution of the bunching coefficients $b_{\rm n}^2 (z)$ for SASE FEL with two-frequency undulator: n = 1 – red line, n = 3 – green line, n = 5 – blue line. The values of the parameters are the same as given in Figure 5.

Figure 6

Fig. 7. Evolution of the energy spread in SASE FEL with two-frequency undulator.