Clinical outcomes after the endovascular treatments of pulmonary vein stenosis in patients with congenital heart disease

Published online by Cambridge University Press:  09 July 2019

Yoshihiko Kurita
Affiliation:
Department of Pediatrics, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama-City, Okayama, Japan
Kenji Baba*
Affiliation:
Department of Pediatrics, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama-City, Okayama, Japan
Maiko Kondo
Affiliation:
Department of Pediatrics, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama-City, Okayama, Japan
Takahiro Eitoku
Affiliation:
Department of Pediatrics, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama-City, Okayama, Japan
Shingo Kasahara
Affiliation:
Department of Cardiovascular surgery, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama-City, Okayama, Japan
Tatsuo Iwasaki
Affiliation:
Department of Anesthesiology and Resuscitology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama-City, Okayama, Japan
Shinichi Ohtsuki
Affiliation:
Department of Pediatrics, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama-City, Okayama, Japan
Hirokazu Tsukahara
Affiliation:
Department of Pediatrics, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama-City, Okayama, Japan
*
Author for correspondence: K. Baba, MD, PhD, Department of Pediatrics, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, 2-5-1, Shikata-Cho, Kita-Ku, Okayama-City, Okayama, 700-8558, Japan. Tel: +81-86-235-7249; Fax: +81-86-221-4745; E-mail: kenjibaba@cc.okayama-u.ac.jp
Rights & Permissions [Opens in a new window]

Abstract

Background:

Pulmonary vein stenosis (PVS) is a condition with challenging treatment and leads to severe cardiac failure and pulmonary hypertension. Despite aggressive surgical or catheter-based intervention, the prognosis of PVS is unsatisfactory. This study aimed to assess the prognosis and to establish appropriate treatment strategies.

Methods:

We retrospectively reviewed endovascular treatments for PVS (2001–2017) from the clinical database at the Okayama University Hospital.

Results:

A total of 24 patients underwent PVS associated with total anomalous pulmonary venous connection and 7 patients underwent isolated congenital PVS. In total, 53 stenotic pulmonary veins were subjected to endovascular treatments; 40 of them were stented by hybrid (29) and percutaneous procedures (11) (bare-metal stent, n = 34; drug-eluting stent, n = 9). Stent size of hybrid stenting was larger than percutaneous stenting. Median follow-up duration from the onset of PVS was 24 months (4–134 months). Survival rate was 71 and 49% at 1 and 5 years, respectively. There was no statistically significant difference between stent placement and survival; however, patients who underwent bare-metal stent implantation had statistically better survival than those who underwent drug-eluting stent implantation or balloon angioplasty. Early onset of stenosis, timing of stenting, and small vessel diameter of pulmonary vein before stenting were considered as risk factors for in-stent restenosis. Freedom from re-intervention was 50 and 26% at 1 and 2 years.

Conclusions:

To improve survival and stent patency, implantation of large stent is important. However, re-intervention after stenting is also significant to obtain good outcome.

Information

Type
Original Article
Copyright
© Cambridge University Press 2019 
Figure 0

Figure 1. (a) Surgical view before hybrid pulmonary vein stenting, two orifices of pulmonary vein are very close (arrow). (b) After hybrid pulmonary vein stenting, two Express Vascular stents were implanted simultaneously. Both stents were of 5 mm size and 15 mm length. Cutting of extra stent strut and anchoring suture were placed to prevent migration.

Figure 1

Table 1. Patient demographics and diagnostic data of pulmonary vein stenosis

Figure 2

Table 2. Details about balloon angioplasty (BAP) of pulmonary vein stenosis

Figure 3

Table 3. Difference between hybrid pulmonary vein stenting (HPVS) and percutaneous pulmonary vein stenting (PPVS)

Figure 4

Table 4. Stent types and characteristics, comparison between bare-metal stents (BMS) and drug-eluting stent (DES)

Figure 5

Figure 2. (a) Kaplan-Meier analysis of patients treated for pulmonary vein stenosis. In overall, estimated survival is 71% and 49% at 1 years and 5 years. There is no significant difference between stent group and balloon angioplasty (BAP) group. (b)Kaplan-Meier comparing survival of patients who received bare-metal stent (BMS) implantation and patients who received only drug-eluting stent (DES) or only balloon angioplasty (BAP).

Figure 6

Table 5. Association with mortality of patients for pulmonary vein stenosis

Figure 7

Table 6. Comparison of pulmonary vein stent with intra-stent restenosis (ISR) or not

Figure 8

Figure 3. Kaplan-Meier analysis showing vascular outcome. Stent implanted with diameter ≥8 mm had a longer freedom from in-stent restenosis (ISR) (p = 0.04).

Figure 9

Figure 4. Kaplan-Meier analysis of re-intervention for pulmonary vein stents. Free from re-intervention of pulmonary vein stent is 50 and 26% at 1 and 2 years, respectively.

Figure 10

Figure 5. Angiogram and computed tomography of a patients who has isolated congenital pulmonary vein stenosis and common atrioventricular valve defect. Four pulmonary veins developed severe stenosis at early infantile period. (a) Right lower pulmonary vein stenosis of orifice before hybrid stenting at 11 months from birth. Two left stents were placed by percutaneous procedure. (b) Computed tomography of right upper and lower pulmonary vein stenosis. Two orifices of pulmonary vein were very close. (c) In-stent stenosis 10 months after placement of 5 mm bare-metal stent by hybrid procedure. (d) Follow-up catheter evaluation showed good patency except the occluded right upper pulmonary vein. This is the recent angiogram 5 years after stenting. This patient underwent trans-catheter re-interventions by balloon six times.