Catheter-based closure of a perimembranous ventricular septal defect using the Amplatzer™ occluder in a patient with right-sided heart and mirror-imaged arrangements of all organs

Published online by Cambridge University Press:  16 September 2005

Per G. Bjørnstad
Affiliation:
Paediatric Cardiology, Rikshospitalet – The National Hospital, University of Oslo, Oslo, Norway
Bjarne Smevik
Affiliation:
Paediatric Radiology, Rikshospitalet – The National Hospital, University of Oslo, Oslo, Norway
Rights & Permissions [Opens in a new window]

Abstract

We describe a 6-year-old boy with a right-sided heart part of the Kartagener syndrome, complicated by presence of a perimembranous ventricular septal defect. The defect was closed interventionally using the Amplatzer™ asymmetrical occluder for ventricular septal defects. The procedure was event-free. Non-operative closure of a ventricular septal defect in this patient demonstrated no other difficulty than mirror-imaged thinking, thus giving evidence that such treatment also can be offered to patients with positional anomalies.

Information

Type
Brief Report
Copyright
© 2005 Cambridge University Press
Figure 0

(a) The guide wire (dotted, short arrow) passed from the femoral artery, right-sided aorta and left ventricle across the ventricular septal defect and into the pulmonary trunk (solid arrow). It has been snared in the stem of the pulmonary trunk (open arrow), with a goose neck snare entered through the femoral vein (long dotted arrow). The echo probe (TOE) is in the oesophagus. As shown in (b), the loop runs from the femoral artery, through the right-sided aorta and the ventricular septal defect into the right ventricle, further into the inferior caval vein positioned on the left side, and out of the femoral vein. The delivery sheath has been inserted through the vein, right atrium and ventricle, through the ventricular septal defect and into the apex of the left ventricle (open arrow). The guide wire is shielded with a catheter, the solid arrow indicating its tip. The set-up is ready for implantation of the device.

Figure 1

Angiocardiography (a) was performed in the cranially angled right anterior oblique view with injection of contrast medium into the left ventricle (LV) and filling of the aorta (Ao) as a last check before detaching the device. The delivery cable is still attached to the connection screw of the device (open arrow). The position of the device seems to be correct, and there is at most a minimal leakage of contrast medium into the right ventricle. The final angiogram (b), taken in the same projection as in (a) with injection of contrast medium into the left ventricle (LV) after release of the device, demonstrates its good position (open arrow). The shunt is no longer present. The guide wire in the oesophagus is used for calibration of measurements (two solid arrows).