Water-Enhanced Turbofan condenser sizing considering configuration and operating conditions

Published online by Cambridge University Press:  26 February 2025

P. Ziegler*
Affiliation:
MTU Aero Engines AG, Munich, Germany
C. Simson
Affiliation:
MTU Aero Engines AG, Munich, Germany
T. Arzberger
Affiliation:
MTU Aero Engines AG, Munich, Germany
A. Woitalka
Affiliation:
MTU Aero Engines AG, Munich, Germany
F. Nöske
Affiliation:
MTU Aero Engines AG, Munich, Germany
S. Kaiser
Affiliation:
MTU Aero Engines AG, Munich, Germany
V. Gümmer
Affiliation:
Technical University of Munich, Munich, Germany
*
Corresponding author: Paul Ziegler; Email: paul.ziegler@mtu.de
Rights & Permissions [Opens in a new window]

Abstract

The Water-Enhanced Turbofan is a promising aero engine propulsion concept that could reduce the climate impact of aviation significantly by combining the conventional Joule/Brayton cycle with a Clausius-Rankine steam cycle. One important component with a high impact on the overall performance is the condenser, a heat exchanger cooling the core exhaust for water recovery. The design conditions for the Water-Enhanced Turbofan condenser have not been analysed from a system perspective in previous studies. Therefore, these operating conditions, which can be decisive for the dimensioning of the condenser, are investigated in the present work. These operating conditions include ambient temperature variations, different cruise altitudes, maximum cruise thrust and contrail avoidance. A conceptual design engine model is set up in the Numerical Propulsion System Simulation (NPSS) framework, incorporating a multi-point design scheme. The heat exchangers are modelled using a neural network surrogate model. The results show a trade-off between engine fuel burn and the cold size frontal area of the condenser, the latter being an indication for the integrability. It is shown that high ambient temperatures pose a challenge to the condenser design, necessitating consideration of such operating conditions in new engine concepts based on heat exchange with the environment. The condenser designed for typical cruise at 15K above standard atmosphere at 35,000 ft cruise altitude, enables sustained water cycle operations down to 10,000 ft under standard day conditions. Additionally, the complete cruise segment of the design mission can be flown with sustained water cycle operations at 10K above standard atmosphere conditions. A positive side effect of the condenser sizing for hot day conditions is that the probability of contrail formation is reduced because the condenser design results in excess water recovery at colder ambient conditions.

Information

Type
Research Article
Copyright
© The Author(s), 2025. Published by Cambridge University Press on behalf of Royal Aeronautical Society
Figure 0

Figure 1. Schematic of the Water-Enhanced Turbofan Concept, adopted from Ref. [8].

Figure 1

Figure 2. Comparison of the change in specific net thrust due to a relative pressure loss and heat addition of ${\rm{\Delta }}q = 20\frac{{kW}}{{kg/s}}$ for typical bypass and ram air flow conditions at cruise altitude.

Figure 2

Figure 3. Amount of gaseous water remaining in the core exhaust, relative to an approximate amount of water from combustion for different operating conditions and an idealised heat exchanger of perfect efficiency.

Figure 3

Figure 4. Sketch of the important geometric parameters of oblique heat exchanger integration at an inclination angle $\alpha $ and a stagger angle $\beta $ as used for the condenser, adopted from Ref. [14].

Figure 4

Figure 5. Simplified block diagram of the Water-Enhanced Turbofan with station nomenclature, adopted from Ref. [8].

Figure 5

Figure 6. Sketch of the condenser with the definition of its outer dimensions as used subsequently.

Figure 6

Table 1. Relative accuracy in terms of root mean square error (RMS) of the heat exchanger surrogate model based on the test dataset

Figure 7

Figure 7. Multi-point design scheme flow chart for the WET concept design.

Figure 8

Figure 8. Pareto-optimum of fuel burn and condenser cold side area obtained using a genetic algorithm on the WET engine model. The reference design is marked with an asterisk.

Figure 9

Table 2. Upper and lower bounds of the design variables in the multi-objective optimisation relative to the reference design

Figure 10

Table 3. Design parameters of the reference design at the typical cruise point (35000ft, M0.78, ISA)

Figure 11

Table 4. Parameters of the reference design for the maximum take-off thrust point (sea level, M0.25, ISA+15K)

Figure 12

Figure 9. Distribution (spatial and temporally) of the ambient air temperature relative to the ISA standard atmosphere at FL340 (pressure level 250hPa) in Europe (30° N to 70° N, 20° W to 40° E) and India (0° N to 30° N, 65° E to 90° E) based on hourly reanalysis data of the ECMWF ERA5 model [23].

Figure 13

Figure 10. Impact of the ambient temperature and impact of water recovery factor, fan diameter and variable nozzles on the condenser sizing.

Figure 14

Figure 11. Water recovery at cruise altitudes between FL100 and FL360 at different ISA conditions at typical cruise aircraft mass and a calibrated airspeed of 230kt with the condenser sized at ISA+15K with $WR{F_{rel}}$ =1.043, ${D_{fan,rel}} = 1.091$, ${A_{290,rel}} = 1.1$

Figure 15

Figure 12. Mixing of the engine plume with ice saturated ambient air for different ambient temperatures for a conventional turbofan and the WET concept. Scenario 1 assumes that all liquid water in the WET exhaust is in gaseous phase before mixing with ambient conditions. Scenario 2 assumes that all liquid water remains in liquid/solid phase during the mixing process with ambient air. In reality a transition from scenario 2 to scenario 1 is expected while the plume mixes with ambient air.

Figure 16

Figure 13. Pareto-optimum of fuel burn and condenser cold side area obtained using a genetic algorithm on the WET engine model. The multi-point design approach includes the typical cruise ISA+15 K operating point with a reduced flight Mach number of 0.7 and an adjusted hot bypass nozzle of ${A_{290,rel}} = 1.1$ as the condenser sizing point. Compared to the reference design, this study also includes an increased water recovery factor of $WR{F_{rel}} = 1.043$ and an increased fan diameter ${D_{fan,rel}} = 1.091$.