The indentation hardness of silicon measured by instrumented indentation: What does it mean?

Published online by Cambridge University Press:  05 December 2012

Bianca Haberl*
Affiliation:
Department of Electronic Materials Engineering, Research School of Physics and Engineering, The Australian National University, Canberra, Australian Capital Territory 0200, Australia
Leonardus Bimo Bayu Aji
Affiliation:
Department of Electronic Materials Engineering, Research School of Physics and Engineering, The Australian National University, Canberra, Australian Capital Territory 0200, Australia
J.S. Williams
Affiliation:
Department of Electronic Materials Engineering, Research School of Physics and Engineering, The Australian National University, Canberra, Australian Capital Territory 0200, Australia
Jodie E. Bradby
Affiliation:
Department of Electronic Materials Engineering, Research School of Physics and Engineering, The Australian National University, Canberra, Australian Capital Territory 0200, Australia
*
a)Address all correspondence to this author. e-mail: bianca.haberl@anu.edu.au

Abstract

The indentation hardness of three different pure forms of silicon was investigated by two different methods. The hardness was probed by direct imaging of the residual impressions and by instrumented indentation using the Oliver–Pharr method. The forms of silicon used were a defective form of amorphous silicon, an amorphous form close to a continuous random network, and a crystalline silicon. The first form deforms via plastic flow and the latter two via phase transition. Two different unloading rates, fast and slow, were used to vary the phase transition behavior. This influenced the relative hardness as measured by instrumented indentation, which is not a reliable method to quantify hardness values in phase transforming materials. Thus, for our phase transforming silicon system, the relative hardness between samples can only be determined correctly by direct imaging, provided that the image accurately reveals the extent of the phase transformed volume.

Information

Type
Articles
Copyright
Copyright © Materials Research Society 2012
Figure 0

TABLE I. The IH and stiffness of as-prepared and relaxed a-Si and c-Si measured by the Oliver–Pharr method (SOP and IHOP) and by SEM scanning (IHSEM).

Figure 1

FIG. 1. SEM micrograph of a representative Berkovich indent performed with the fast unloading rate in as-implanted a-Si.

Figure 2

FIG. 2. IH of the different forms of Si measured by instrumented indentation (triangles) and direct SEM imaging (circles). In all cases, fast unloading is represented by closed symbols and slow unloading by open symbols. Note that IHOP and IHSEMare normalized for the as-implanted case with an offset of the scales of 1.25 GPa.