Hostname: page-component-74656f9884-7drmj Total loading time: 0 Render date: 2026-11-04T21:55:32.368Z Has data issue: false hasContentIssue false

Qualitative and quantitative evaluation of auto-segmented clinical target volumes and organs at risk in radiotherapy of rectal cancer

Published online by Cambridge University Press:  26 March 2026

Love Dahlstedt-Hassler*
Affiliation:
Department of Oncology, Södersjukhuset: Sodersjukhuset, Stockholm, Sweden Department of Clinical Science and Education, Södersjukhuset, Karolinska Institutet, Stockholm, Sweden
Albert Siegbahn
Affiliation:
Department of Oncology, Södersjukhuset: Sodersjukhuset, Stockholm, Sweden Department of Clinical Science and Education, Södersjukhuset, Karolinska Institutet, Stockholm, Sweden
Rafat Kojoj
Affiliation:
Department of Oncology, Södersjukhuset: Sodersjukhuset, Stockholm, Sweden
Anna Schedin
Affiliation:
Department of Oncology, Södersjukhuset: Sodersjukhuset, Stockholm, Sweden
Cecilia Lagerbäck
Affiliation:
Department of Oncology, Södersjukhuset: Sodersjukhuset, Stockholm, Sweden
Pehr Lind
Affiliation:
Department of Oncology, Södersjukhuset: Sodersjukhuset, Stockholm, Sweden Department of Clinical Science and Education, Södersjukhuset, Karolinska Institutet, Stockholm, Sweden
*
Corresponding author: Love Dahlstedt-Hassler; Email: love.dahlstedt-hassler@regionstockholm.se
Rights & Permissions [Opens in a new window]

Abstract

Introduction:

Manual contouring (MC) is time-consuming work in radiotherapy planning for rectal cancer. Artificial intelligence (AI) can reduce the time required for clinical target volume (CTV) and organs-at-risk (OARs) delineation. In this study, we evaluated the quality of auto-segmented CTVs and OARs.

Methods:

Dose-planning data were collected from ten patients who underwent preoperative radiotherapy for locally advanced rectal cancer in 2024. Auto-segmented structures from the AI-Rad and Contour+ software tools were added. Constructed AI-CTVs, based on Contour+ segmentations and AI-OARs, i.e., bladder, femoral heads and bowel bag, by both AI tools, were compared to their MC counterparts by use of quantitative metrics, volumetric/surface Dice similarity coefficients (vDSC/sDSC) and maximum/average Hausdorff distance (HD/aHD). The constructed AI-CTVs and MC counterparts were graded by two radiotherapists with two qualitative methods.

Results:

The median vDSC, sDSC, HD and aHD values of our constructed AI-CTVs compared with the MC-CTVs were 0.86, 0.61, 23.19 and 0.62 mm, respectively. For both AI tools, the agreement in the OAR metrics was overall good but less similar for the bowel bag. The qualitative evaluations of the AI-CTVs, compared to the MC-CTVs, were in clear favour of the MC-CTVs. The cranial-anterior nodal levels were anatomical areas with poorer coverage, where the contouring guidelines differed.

Conclusion:

The quality of our constructed AI-CTVs was inferior to the MC-CTVs. Thus, the auto-segmentation methods need further development on this aspect for use in the clinical setting. In contrast, the agreement of the quantitative metrics for the OARs was overall good, except for the bowel bag.

Information

Type
Original Article
Creative Commons
Creative Common License - CCCreative Common License - BY
This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution and reproduction, provided the original article is properly cited.
Copyright
© The Author(s), 2026. Published by Cambridge University Press
Figure 0

Figure 1. Images from a single case illustrating the steps involved in constructing the AI-CTV. (a) AI-rectum + AI-recto-sigmoideum (blue) & MC-GTV (red). (b) MC-GTV (red) & AI-GTV (green). (c) AI-GTV (dark green) & margin (light green). (d) AI-GTV + margin (green) & AI-Ln-Rectal (orange). (e) AI-CTV (yellow). (f) MC-CTV (pink). Abbreviations: AI, artificial intelligence; MC, manual contours; GTV, gross tumour volume; Ln, lymph nodal volume; CTV, clinical target volume.

Figure 1

Figure 2. Sagittal view of the intersection between auto-segmentation-based structures and manual contoured target structures. (a) Red colour: MC-CTVT. Green Colour: Constructed AI GTV (Contour+ based). (b) Red colour: MC-CTV. Green Colour: Auto-segmented left internal iliac nodal volume (AI-Rad). Abbreviations: MC, manual contours; CTVT, clinical target volume of tumour; GTV, gross tumour volume; CTV, clinical target volume (including nodal fields); AI, artificial intelligence.

Figure 2

Table 1. Grading test: questions assessing clinical benefit of CTV structures

Figure 3

Figure 3. Examples of slices reviewed in the preference test. The slices were arranged from caudal to cranial direction. The colour given to structures was individually randomised in each slice. (a) AI: red, MC: green. (b) AI: green, MC: red. (c) AI: green, MC: red. (d) AI: red, MC: green. Abbreviations: AI, constructed clinical target volume (CTV); MC, manually contoured CTV.

Figure 4

Table 2. Summary of statistics for quantitative metrics

Figure 5

Table 3. Case-by-case display of qualitative metrics and qualitative test scores for the constructed AI and MC CTV, including nodal fields

Figure 6

Table 4. Correlation coefficient values of quantitative metrics versus grading test results of the constructed AI-CTV, 5-point and 3-point scales