Generation of runaway electrons and X rays in an inhomogeneous electric field at high gas pressures

Published online by Cambridge University Press:  28 November 2016

V.F. Tarasenko
Affiliation:
Institute of High Current Electronics, Tomsk 634055, Russia National Research Tomsk State University, Tomsk 634050, Russia National Research Tomsk Polytechnic University, Tomsk 634050, Russia
E.Kh. Baksht
Affiliation:
Institute of High Current Electronics, Tomsk 634055, Russia
D.V. Beloplotov*
Affiliation:
Institute of High Current Electronics, Tomsk 634055, Russia National Research Tomsk State University, Tomsk 634050, Russia
A.G. Burachenko
Affiliation:
Institute of High Current Electronics, Tomsk 634055, Russia National Research Tomsk State University, Tomsk 634050, Russia
M.I. Lomaev
Affiliation:
Institute of High Current Electronics, Tomsk 634055, Russia National Research Tomsk State University, Tomsk 634050, Russia
D.A. Sorokin
Affiliation:
Institute of High Current Electronics, Tomsk 634055, Russia
*
Address correspondence and reprint requests to: D.V. Beloplotov, Institute of High Current Electronics, Russian Academy of Science, Akademichesky Avenue 2/3, Tomsk, 634055, Russia. E-mail: rff.qep.bdim@gmail.com

Abstract

Results of experimental studies of the amplitude–temporal characteristics of a runaway electron (RE) beam, as well as breakdown voltage and discharge current with a picosecond time resolution are presented. The maximum pressure, at which a RE beam is detectable, decreases with increasing the voltage rise time. The waveforms of the discharge and RE beam currents are synchronized with those of the voltage pulses. It is shown that the amplitude–temporal characteristics of the RE beam depend on the designs of the gas-filled diode and cathode, as well as the gap length. The mechanism for the generation of REs in atmospheric-pressure gases is analyzed on the basis of the obtained experimental data.

Information

Type
Research Article
Copyright
Copyright © Cambridge University Press 2016 
Figure 0

Fig. 1. Schematic representation of the output of the RADAN-220 pulser with the gas-filed diode, shunt, and collector: 1 – transmission line, 2 – capacitive voltage divider, 3 – insulator, 4 – conical cathode, 5 – quartz windows, 6 – foil or grid anode, 7 – Al foil, 8 – collector case, 9–20-mm-diameter receiving part of the collector, and 10 – film low-inductance chip resistors.

Figure 1

Fig. 2. Schematic of the output of the SLEP-150 pulser, gas-filed diode, and collector with the 3-mm-diameter receiving area: 1 – high-voltage line of the pulser, 2 – peaking spark gap, 3 – transmission line, 4 – capacitive voltage divider, 5 – gas-filed diode, 6 – tubular cathode, 7 – receiver part of the collector, 8 – foil, 9 – 5-mm-thick collimator with a 1-mm-diameter hole, and 10 – collector case. On the left, several turns of the high-voltage coil of the pulsed transformer are shown. On the right, the inductance coil connecting the inner electrode of the transmission line to the pulser case is shown on the insulator.

Figure 2

Fig. 3. Time-integrated images of the discharge plasma glow in atmospheric-pressure nitrogen (a) and air (b, c), as well as SAEB print on an RF-3 film (d), obtained on the setups with the RADAN-220 pulser (a, b) and the SLEP-150 pulser (c, d) per one pulse. Gap lengths is 14 mm (a, b) and 11 mm (c, d). The diameter of the tubular cathode located on the left in frames (a) and (b) is 6 mm, and that of the tubular cathode located in the centers of frames (c) and (d) is 7 mm.

Figure 3

Fig. 4. Waveforms of the voltage (a) and discharge current (b) pulses at different gap lengths. The cathode is a 6-mm-diameter tube. The waveforms were obtained on the setup with the SLEP-150 pulser.

Figure 4

Fig. 5. Waveforms of the voltage (a) and discharge current (b) pulses registered in the initial stage of the discharge on the setup with the SLEP-150 pulser at different gap length. The cathode is a 6-mm-diameter tube. Time intervals А, B, and C correspond to the current of the “cold” diode (displacement current), dynamic displacement current, and conduction current, respectively.

Figure 5

Fig. 6. Waveforms of the voltage (a) and the SAEB current (b) pulses. The SAEB was registered by collector with the 20-mm-diameter receiving area: 1, 3 – the anode is a grid with a transparency of 64%; 2, 4 – the anode is a 10-μm-thick aluminum foil. The cathode is a 6-mm-diameter tube. The gap length is d = 12 mm. The waveforms were obtained on the setup with the SLEP-150 pulser. Time intervals А, B, and C correspond to the current of the “cold” diode (displacement current), dynamic displacement current, and conduction current, respectively.

Figure 6

Fig. 7. Waveforms of the voltage (a) and the SAEB current (b) pulses. The SAEB was registered by collector with the 3-mm-diameter receiving area, located behind a 5-mm-thick collimator with a 1-mm-diameter hole and a 10-μm-thick aluminum foil at different gap length. The cathode is a 6-mm-diameter tube. The waveforms were obtained on the setup with the SLEP-150 pulser.

Figure 7

Fig. 8. Waveforms of the voltage (a) and the SAEB current (b) pulses. The SAEB was registered by a collector with the 3-mm-diameter receiving area, located behind a collimator with a 1-mm-diameter hole and a 10-μm-thick aluminum foil: 1 – per one pulse; 2, 3 – averaged over 25 pulses. The collimator hole is located on the axis of the gas-filed diode (1, 3), and at a distance of 19 mm from the axis (2). The gap length is 6 mm. The cathode is a grid fixed on a 30-mm-diameter ring. The waveforms were obtained on the setup with the SLEP-150 pulser.

Figure 8

Fig. 9. Waveforms of the SAEB current pulses registered by a collector with diameter receiving area of 3 (a−c, f) and 20 mm (d, e). The collector was located behind a collimator with a hole diameter of 1 (a, b, f), 4 (c), and 18 mm (d, e). The cathode is a sphere (a) and a tube (b−f). The gap length is 6 (a) and 12 mm (b–f).

Figure 9

Fig. 10. Calculated numbers of electrons behind aluminum foils of different thickness for monoenergetic beams with different electron energies and experimental SAEB attenuation curve obtained for d = 12 mm on the setup with the SLEP-150М pulser with the tubular cathode at Um = 170 kV: 1–50, 2–100, 3–150, 4–200, and 5–250 keV.

Figure 10

Fig. 11. SAEB current amplitude versus pressure for different gases.

Figure 11

Fig. 12. SAEB current amplitude versus pressure for different gases. The SAEB was detected by a 20-mm-collector located behind a grid anode with 64% transparency and foil: (a) – air and SF6, Al foil 10 µm thick, d = 8 mm; (b) – N2, plated ketoprofen film 2 µm thick downstream of grid anode, d = 12 mm. Values for SF6 are multiplied by 100.