Successful replacement of the systemic tricuspid valve with a mechanical valve in a 3-month-old boy with congenitally corrected transposition of the great arteries having a dysplastic tricuspid valve

Published online by Cambridge University Press:  29 September 2016

Dai Asada*
Affiliation:
Department of Pediatric Cardiology and Nephrology, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto, Japan
Kazuyuki Ikeda
Affiliation:
Department of Pediatric Cardiology and Nephrology, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto, Japan
Masaaki Yamagishi
Affiliation:
Department of Pediatric Cardiovascular Surgery, Children’s Medical Center, Kyoto Prefectural University of Medicine, Kyoto, Japan
*
Correspondence to: D. Asada, Department of Pediatric Cardiology and Nephrology, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, 465 Kajii-cho, Kawaramachi-Hirokoji, Kamigyo-ku, Kyoto 602-8566, Japan. Tel: +81 75 251 5832; Fax: +81 75 251 5833; E-mail: asadadai@koto.kpu-m.ac.jp
Rights & Permissions [Opens in a new window]

Abstract

There are a few reports of successful replacement of the left-sided systemic tricuspid valve with a mechanical valve in small infants with congenitally corrected transposition of the great arteries having Ebstein’s anomaly. Tricuspid valve replacement is the preferred option when pulmonary artery banding, performed as a prelude to performing the double-switch operation, is not feasible because of severe heart failure caused by tricuspid regurgitation.

Information

Type
Brief Report
Copyright
© Cambridge University Press 2016 
Figure 0

Figure 1Chest X-ray before and after tricuspid valve replacement (TVR). (a) Chest X-ray after pulmonary artery banding demonstrated pulmonary congestion. The black arrow indicates the implanted pacemaker. (b) Post-TVR chest X-ray demonstrated normal pulmonary blood flow. The black arrow indicates the mechanical valve.

Figure 1

Figure 2Tricuspid valve replacement with expanded polytetrafluoroethylene (ePTFE) graft. Both sides of an ePTFE graft (20-mm diameter) were cut and sewn into sides of 17-mm diameter. This ePTFE graft (17-mm diameter, 7-mm height) was set into the native annulus as a base. The mechanical valve (ATS-AP mitral valve Φ16 mm) was set onto this base as supra-annular valve replacement (top-hat method).