Hostname: page-component-74656f9884-c52kr Total loading time: 0 Render date: 2026-11-07T08:28:34.783Z Has data issue: false hasContentIssue false

Aerodynamic droplet atomization model (ADAM)

Published online by Cambridge University Press:  27 February 2023

Isaac M. Jackiw
Affiliation:
Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, ON M5S 3G8, Canada
Nasser Ashgriz*
Affiliation:
Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, ON M5S 3G8, Canada
*
†Email address for correspondence: ashgriz@mie.utoronto.ca

Abstract

The present work studies low viscosity twin-fluid atomization experimentally and analytically to characterize and predict the droplet size distribution of the spray. The study is based on experiments conducted using commercially available twin-fluid nozzles with water as the liquid. Shadowgraph images were used to visualize the near-nozzle flow while the droplet size distribution was measured in the far field using a Malvern Spraytec. To analytically model the atomization of the spray, the authors’ recent works on aerodynamic droplet breakup, which describe the formation and breakup of ligament and bag structures by multiple mechanisms, are extended to provide an analytical prediction of the droplet size distribution of the spray that is validated against the present experiments. The present model is developed to be a good physical representation of the spray behaviour at practical operating conditions. A Python implementation of the model has been deposited in a GitHub repository to accompany this work.

Information

Type
JFM Papers
Copyright
© The Author(s), 2023. Published by Cambridge University Press
Figure 0

Figure 1. Images of a typical twin-fluid spray; 2850-70 nozzle operating at $G_l = 526$ kg m$^{-2}$ s$^{-1}$ with (a) $G_g = 210$ kg m$^{-2}$ s$^{-1}$ and (b) $G_g = 319$ kg m$^{-2}$ s$^{-1}$.

Figure 1

Figure 2. Illustration of nozzle and its dimensions.

Figure 2

Table 1. Dimensions in mm of Spraying Systems Co. 1/4J nozzles used in present study. Here $b_g=(d_{g,o} - d_{g,i})/2 \approx 0.25$ mm for all nozzle set-ups.

Figure 3

Figure 3. Images of spray showing transition from varicose to sinuous waves and their breakup; 2850-70 nozzle at $G_l = 1315$ kg m$^{-2}$ s$^{-1}$ and $G_g = 143$ kg m$^{-2}$ s$^{-1}$.

Figure 4

Figure 4. Image of a twin-fluid spray showing the (1) nodes, (2) remaining rim and (3) bag structures that form during the breakup; 2850-70 nozzle at $G_l = 526$ kg m$^{-2}$ s$^{-1}$ and $G_g = 111$ kg m$^{-2}$ s$^{-1}$. Inset shows the aerodynamic breakup of a droplet in the bag morphology, exhibiting the same geometries.

Figure 5

Figure 5. Images of spray at high gas speed; 2850-70 nozzle at $G_l = 263$ kg m$^{-2}$ s$^{-1}$ and $G_g = 535$ kg m$^{-2}$ s$^{-1}$.

Figure 6

Figure 6. Images of the spray near the nozzle. The droplet size histograms of the spray at the corresponding conditions at various distances from the nozzle are shown in figure 7; 2850-70 nozzle at $G_l = 789$ kg m$^{-2}$ s$^{-1}$ and $G_g = 230$ kg m$^{-2}$ s$^{-1}$.

Figure 7

Figure 7. Droplet size histograms showing the effect of distance on the distribution evolution; 2850-70 nozzle at $G_l = 789$ kg m$^{-2}$ s$^{-1}$ and $G_g = 230$ kg m$^{-2}$ s$^{-1}$. Vertical lines are placed at $d=40\,\mathrm {\mu }$m for all cases to highlight how the location of the smaller mode does not change significantly as the spray develops. Results are shown for (a) $x=20$ mm, (b) $x=40$ mm, (c) $x=60$ mm, (d) $x=80$ mm.

Figure 8

Figure 8. Effect of distance on the $d_{32}$ of the spray at varying measurement distances, $x$; 2850-70 nozzle at $G_l=789$ kg m$^{-2}$ s$^{-1}$ and $G_g = 230$ kg m$^{-2}$ s$^{-1}$. Error bars show the standard deviation of each measurement.

Figure 9

Figure 9. Droplet size frequency histograms of the spray from the 2850-70 nozzle for varying $G_g$ and for low (a–d) and high (e–h) $G_l$ at $x=80$ mm. Flow conditions are indicated on the figure. Results are shown for (a) $G_g=143$, $G_l=263\,{\rm kg}\,{\rm m}^{-2}\,{\rm s}^{-1}$; (b) $G_g=210$, $G_l=263\,{\rm kg}\,{\rm m}^{-2}\,{\rm s}^{-1}$; (c) $G_g=289$, $G_l=263\,{\rm kg}\,{\rm m}^{-2}\,{\rm s}^{-1}$; (d) $G_g=535$, $G_l=263\,{\rm kg}\,{\rm m}^{-2}\,{\rm s}^{-1}$; (e) $G_g=143$, $G_l=1315\,{\rm kg}\,{\rm m}^{-2}\,{\rm s}^{-1}$; (f) $G_g=210$, $G_l=1315\,{\rm kg}\,{\rm m}^{-2}\,{\rm s}^{-1}$; (g) $G_g=289$, $G_l=1315\,{\rm kg}\,{\rm m}^{-2}\,{\rm s}^{-1}$; (h) $G_g=535$, $G_l=1315\,{\rm kg}\,{\rm m}^{-2}\,{\rm s}^{-1}$.

Figure 10

Figure 10. Images showing liquid wetting across the nozzle face. The main image shows the case with no gas flow, where the liquid jet emerges at the liquid orifice diameter. The overlaid ‘ghost’ image shows the case with gas flow, where the liquid jet wets across the face of the liquid nozzle.

Figure 11

Figure 11. (a) Comparison of $d_{32}$ of sprays from 2850-70 and 2050-70 nozzles at varying $G_g$ and of (b) volume-frequency size histogram at fixed $G_g=319$ kg m$^{-2}$ s$^{-1}$. $G_l=526$ kg m$^{-2}$ s$^{-1}$ and $x=80$ mm for both plots. The arrow call-out in (a) indicates the conditions for which the size distributions are plotted in (b). The histograms are plotted in (b) as marked lines for clarity, where the height and centres of the bins are given by the markers.

Figure 12

Figure 12. Volume-frequency droplet size histograms of the sprays from the 2850-70 (a,b) and 60100-120 (c,d) nozzles at two similar $G_g$ (a,c and b,d) for similar $G_l$. Conditions are indicated on the figure. For all cases, $x=80$ mm. Histograms correspond to images in figure 13.

Figure 13

Figure 13. Images of sprays from the (a,b) 2850-70 and (c,d) 60100-120 nozzles at two similar $G_g$ (a,c and b,d) for similar $G_l$. Conditions are indicated on the figure. For all cases, $x=80$ mm. Images correspond to the histograms in figure 12. Results are shown for (a) 2850-70: $G_g=319$, $G_l=526\,{\rm kg}\,{\rm m}^{-2}\,{\rm s}^{-1}$; (b) 2850-70: $G_g=535$, $G_l=526\,{\rm kg}\,{\rm m}^{-2}\,{\rm s}^{-1}$; (c) 60100-120: $G_g=328$, $G_l=493\,{\rm kg}\,{\rm m}^{-2}\,{\rm s}^{-1}$; and (d) 60100-120: $G_g=527$, $G_l=493\,{\rm kg}\,{\rm m}^{-2}\,{\rm s}^{-1}$.

Figure 14

Figure 14. Plot of $d_{3,2}$ vs $G_g$ comparing the sprays of the 2850-70 and 60100-120 nozzles at $x=80$ mm for similar $G_l$ (indicated on the figure). Closed and open markers indicate the conditions at which the atomization is complete or incomplete, respectively.

Figure 15

Figure 15. Plot of $d_{32}$ vs $G_g$ comparing the sprays of the 2850-70 and 60100-120 nozzles at $x=80$ mm at $\dot {m}_l=1.67$ g s$^{-1}$. Closed and open markers indicate the conditions at which the atomization is complete or incomplete, respectively.

Figure 16

Figure 16. Illustration of the liquid stream thinning, where the liquid jet of initial diameter $d_l$ wicks across the face of the nozzle to $d_{g,i}$ and is accelerated by the surrounding gas flow, $u_g$, from $u_l$ to $u_c$, leading to the thinning of the liquid stream to $d_l'$.

Figure 17

Table 2. Relationships between final rim diameter, $2R_f$, and bag size at burst, $\beta _f$, and their conditions for the four breakup morphologies. The acronyms B, BS, MB and ST denote bag breakup, bag and stamen breakup, multi-bag breakup and sheet-thinning morphologies, respectively.

Figure 18

Figure 17. Example construction of the predicted distribution for the 2850-70 nozzle at $G_l = 263$ and $G_g = 289$ kg m$^{-2}$ s$^{-1}$. (a–c) Size histograms of the 11 characteristic sizes for the breakup of the initial liquid jet ($j=0$) and the first ($j=1$) and last undeformed core ($j=18$), respectively. The conditions of each breakup event are indicated on the figure. (d) The total size and (e) volume-weighted histograms of the breakup. (f–h) The number and volume probability density distributions, and the volume-frequency histogram, respectively.

Figure 19

Table 3. List of characteristic breakup sizes.

Figure 20

Figure 18. Comparison of predicted and measured droplet size distribution for the 2850-70 nozzle at low (a–d) and high (e–h) $G_l$ and increasing $G_g$ at $x=80$ mm. Flow conditions are indicated on the figure. Results are shown for (a) $G_g = 143$, $G_l = 263\,{\rm kg}\,{\rm m}^{-2}\,{\rm s}^{-1}$; (b) $G_g = 210$, $G_l = 263\,{\rm kg}\,{\rm m}^{-2}\,{\rm s}^{-1}$; (c) $G_g = 289$, $G_l = 263\,{\rm kg}\,{\rm m}^{-2}\,{\rm s}^{-1}$; (d) $G_g = 535$, $G_l = 263\,{\rm kg}\,{\rm m}^{-2}\,{\rm s}^{-1}$; (e) $G_g = 143$, $G_l = 1315\,{\rm kg}\,{\rm m}^{-2}\,{\rm s}^{-1}$; (f) $G_g = 210$, $G_l = 1315\,{\rm kg}\,{\rm m}^{-2}\,{\rm s}^{-1}$; (g) $G_g = 289$, $G_l = 1315\,{\rm kg}\,{\rm m}^{-2}\,{\rm s}^{-1}$; and (h) $G_g = 535$, $G_l = 1315\,{\rm kg}\,{\rm m}^{-2}\,{\rm s}^{-1}$.

Figure 21

Figure 19. Comparison of predicted and measured droplet size distribution for the 60100-120 nozzle at $G_l=164$ kg m$^{-2}$ s$^{-1}$ and increasing $G_g$ from (a–d). Flow conditions are indicated on the figure. Results are shown for (a) $G_g = 140$, $G_l = 164\,{\rm kg}\,{\rm m}^{-2}\,{\rm s}^{-1}$; (b) $G_g = 200$, $G_l = 164\,{\rm kg}\,{\rm m}^{-2}\,{\rm s}^{-1}$; (c) $G_g = 328$, $G_l = 164\,{\rm kg}\,{\rm m}^{-2}\,{\rm s}^{-1}$; (d) $G_g = 527$, $G_l = 164\,{\rm kg}\,{\rm m}^{-2}\,{\rm s}^{-1}$; (e) $G_g = 140$, $G_l = 493\,{\rm kg}\,{\rm m}^{-2}\,{\rm s}^{-1}$; (f) $G_g = 200$, $G_l = 493\,{\rm kg}\,{\rm m}^{-2}\,{\rm s}^{-1}$; (g) $G_g = 328$, $G_l = 493\,{\rm kg}\,{\rm m}^{-2}\,{\rm s}^{-1}$; (h) $G_g = 527$, $G_l = 493\,{\rm kg}\,{\rm m}^{-2}\,{\rm s}^{-1}$.

Figure 22

Figure 20. (a) Comparison of the present model along with those of Varga et al. (2003) and Aliseda et al. (2008), and (b) comparison of the present model alone to the measured $d_{32}$ of the 2850-70 nozzle spray for varying $G_g$ at low $G_l$ and $x=80$ mm. Same for (c,d) at high $G_l$. Flow conditions are indicated on the figure. Results are shown for (a,b) $G_l =263\,{\rm kg}\,{\rm m}^{-2}\,{\rm s}^{-1}$, (c,d) $G_l =1315\,{\rm kg}\,{\rm m}^{-2}\,{\rm s}^{-1}$.

Figure 23

Figure 21. (a) Comparison of the present model along with those of Varga et al. (2003) and Aliseda et al. (2008), and (b) comparison of the present model alone to the measured $d_{32}$ of the 60100-120 nozzle spray for varying $G_g$ at low $G_l$ and $x=80$ mm. Same for (c) and (d) at high $G_l$. Flow conditions are indicated on the figure. Results are shown for (a,b) $G_l =164\,{\rm kg}\,{\rm m}^{-2}\,{\rm s}^{-1}$, and (c,d) $G_l =493\,{\rm kg}\,{\rm m}^{-2}\,{\rm s}^{-1}$.

Figure 24

Figure 22. Comparison of predicted and measured droplet size distribution for the 2850-70 nozzle at low (a–d) and high (e–h) $G_l$ and increasing $G_g$ at $x=80$ mm. Flow conditions are indicated on the figure. The prediction uses $u'_l$ (4.36) in the prediction of the liquid stream thinning. Results are shown for (a) $G_g = 143$, $G_l = 263\,{\rm kg}\,{\rm m}^{-2}\,{\rm s}^{-1}$; (b) $G_g = 210$, $G_l = 263\,{\rm kg}\,{\rm m}^{-2}\,{\rm s}^{-1}$; (c) $G_g = 289$, $G_l = 263\,{\rm kg}\,{\rm m}^{-2}\,{\rm s}^{-1}$; (d) $G_g = 535$, $G_l = 263\,{\rm kg}\,{\rm m}^{-2}\,{\rm s}^{-1}$; (e) $G_g = 143$, $G_l = 1315\,{\rm kg}\,{\rm m}^{-2}\,{\rm s}^{-1}$; (f) $G_g = 210$, $G_l = 1315\,{\rm kg}\,{\rm m}^{-2}\,{\rm s}^{-1}$; (g) $G_g = 289$, $G_l = 1315\,{\rm kg}\,{\rm m}^{-2}\,{\rm s}^{-1}$; (h) $G_g = 535$, $G_l = 1315\,{\rm kg}\,{\rm m}^{-2}\,{\rm s}^{-1}$.

Figure 25

Figure 23. (a) Comparison of the present model along with those of Varga et al. (2003) and Aliseda et al. (2008), and (b) comparison of the present model alone to the measured $d_{32}$ of the 2850-70 nozzle spray for varying $G_g$ at low $G_l$ and $x=80$ mm. Same for (c,d) at high $G_l$. Flow conditions are indicated on the figure. Results are shown for (a,b) $G_l =263\,{\rm kg}\,{\rm m}^{-2}\,{\rm s}^{-1}$, (c,d) $G_l =1315\,{\rm kg}\,{\rm m}^{-2}\,{\rm s}^{-1}$.

Figure 26

Figure 24. Model results over several orders of magnitude of (a) $\rho _g$, (b) $\rho _l$ and (c) $\sigma$. In (a), $u_g = 100$ m s$^{-1}$ and $\rho _g=1.24$ kg m$^{-3}$, while in (b) and (c), $u_g = 200$ m s$^{-1}$ and $\rho _g=1.36$ kg m$^{-3}$. In all cases, $u_l = 0.3$ m s$^{-1}$. Unless otherwise specified, the liquid properties used are $\rho _l = 1000$ kg m$^{-3}$ and $\sigma =0.0729$ N m$^{-1}$, which are the nominal properties for the water base case at similar conditions.

Figure 27

Figure 25. Measured varicose (solid markers) and sinuous (open markers) wavelengths of sprays from the 2850-70 nozzle for varying $G_g$ and $G_l$ compared with the theory of (4.1) at the lowest value of $G_l$. Note that (4.1) is insensitive to $G_l$. The value of $C_{\lambda }$ obtained from the fit as well as the $r^2$ of the fit are indicated on the figure.

Supplementary material: File

Jackiw and Ashgriz supplementary material

Jackiw and Ashgriz supplementary material

Download Jackiw and Ashgriz supplementary material(File)
File 102.1 KB