Hostname: page-component-74656f9884-8r8nv Total loading time: 0 Render date: 2026-11-07T11:19:01.372Z Has data issue: false hasContentIssue false

Auditory steady state response in auditory neuropathy

Published online by Cambridge University Press:  14 April 2010

A A Emara*
Affiliation:
MD Audiology Unit, ENT Department, Tanta University, Cairo, Egypt
T A Gabr
Affiliation:
MD Audiology Unit, ENT Department, Tanta University, Cairo, Egypt
*
Address for correspondence: Dr Afaf Ahmed Emara, Assistant Professor of Audiology, Tanta University, 11 Hassan Radwan Street, Tanta, Egypt. E-mail: Afaf_emara@hotmail.com
Rights & Permissions [Opens in a new window]

Abstract

Review:

Auditory neuropathy is a disorder characterised by preservation of outer hair cell function, with normal otoacoustic emissions and/or cochlear microphonics, but an absent or distorted auditory brainstem response.

Purpose:

This study aimed to objectively assess hearing thresholds in patients with auditory neuropathy, using the auditory steady state response.

Materials and methods:

Thirteen patients with auditory neuropathy and 15 normal hearing subjects were examined. Audiological evaluation included basic audiological tests, otoacoustic emissions, auditory brainstem response and auditory steady state response.

Results:

In the auditory neuropathy patients, the auditory brainstem response was absent in 11 patients, while the auditory steady state response was absent in only three.

Conclusion:

The auditory steady state response may serve as a valuable objective measure for assessing the hearing threshold across different frequencies in patients with auditory neuropathy. We recommend that auditory steady state response be used to complete the evaluation of patients with auditory neuropathy.

Information

Type
Main Articles
Copyright
Copyright © JLO (1984) Limited 2010
Figure 0

Table I Auditory neuropathy patients: gender and audiological results

Figure 1

Table II Auditory neuropathy patients: individual data

Figure 2

Fig. 1 Mean and standard deviation (whiskers) of auditory steady state response (ASSR) and pure tone average (PTA) thresholds at test frequencies, in auditory neuropathy patients.

Figure 3

Fig. 2 Mean pure tone average (PTA) and auditory steady state response (ASSR) thresholds at test frequencies, in auditory neuropathy patients.

Figure 4

Table III Pure tone average vs auditory steady state response thresholds: auditory neuropathy patients

Figure 5

Fig. 3 Mean and standard deviation (whiskers) of auditory steady state response (ASSR) and pure tone average (PTA) thresholds at test frequencies, in normal hearing subjects.

Figure 6

Fig. 4 Mean pure tone average (PTA) and auditory steady state response (ASSR) thresholds at test frequencies, in normal hearing subjects.

Figure 7

Table IV Pure tone average vs auditory steady state response thresholds: normal hearing subjects

Figure 8

Table V Correlation between auditory steady state response and PTA thresholds at different frequencies: auditory neuropathy patients

Figure 9

Table VI Correlation between auditory steady state response and PTA thresholds at different frequencies: normal hearing subjects