Hostname: page-component-74656f9884-2dmjx Total loading time: 0 Render date: 2026-11-07T19:30:26.668Z Has data issue: false hasContentIssue false

Radiocarbon Sample Preparation Procedures and the First Status Report from the Bristol Radiocarbon AMS (BRAMS) Facility

Published online by Cambridge University Press:  31 May 2019

Timothy D J Knowles*
Affiliation:
Bristol Radiocarbon Accelerator Mass Spectrometry Facility, University of Bristol, Bristol, BS8 1UU, UK
Paul S Monaghan
Affiliation:
Bristol Radiocarbon Accelerator Mass Spectrometry Facility, University of Bristol, Bristol, BS8 1UU, UK
Richard P Evershed
Affiliation:
Bristol Radiocarbon Accelerator Mass Spectrometry Facility, University of Bristol, Bristol, BS8 1UU, UK Organic Geochemistry Unit, School of Chemistry, University of Bristol, Bristol, BS8 1TS, UK
*
*Corresponding author. Email: tim.knowles@bristol.ac.uk.
Rights & Permissions [Opens in a new window]

Abstract

The Bristol Radiocarbon Accelerator Mass Spectrometry (BRAMS) Facility was established at the University of Bristol after the commissioning of our dedicated sample preparation laboratories and the installation and acceptance of the BrisMICADAS AMS in 2016. Routine measurements commenced in mid-2016, once validation was completed for each sample type. Herein, we give an overview of the standard pretreatment methods currently employed in the Facility and the results of radiocarbon (14C) determinations on a wide range of standards, blank materials, and intercomparison samples which have been measured during our extensive pretreatment method validation program and during our routine 14C analyses.

Information

Type
Conference Paper
Copyright
© 2019 by the Arizona Board of Regents on behalf of the University of Arizona 
Figure 0

Figure 1 The BrisMICADAS AMS at the University of Bristol.

Figure 1

Table 1 Current 14C blanks in use at BRAMS.

Figure 2

Table 2 Determined F14C values for a range of standards and intercomparison samples.

Figure 3

Figure 2 (A) F14C values determined for IAEA-C7 oxalic acid to date arranged in order of analysis; (B) F14C values determined for IAEA-C8 oxalic acid to date arranged in order of analysis; (C) normalized F14C values from IAEA-C7 and -C8 targets arranged in order of determined normalized F14C value. Horizontal black lines represent literature values. The red line indicates the expected trend from normally distributed data. (Please see electronic version for color figures.)

Figure 4

Table 3 Mean blank values measured at BRAMS.