Transcatheter Harmony pulmonary valve placement in the right pulmonary artery followed by stenting of a hypoplastic left pulmonary artery

Published online by Cambridge University Press:  04 June 2026

Lubna Hashim*
Affiliation:
Medical College of Wisconsin, Milwaukee, WI, USA
Matthew W. Buelow
Affiliation:
Cardiology, Medical College of Wisconsin, Milwaukee, WI, USA
Susan R. Foerster
Affiliation:
Pediatric Cardiology, Medical College of Wisconsin, Milwaukee, WI, USA
Todd M. Gudausky
Affiliation:
Pediatric Cardiology, Medical College of Wisconsin, Milwaukee, WI, USA
Osamah Aldoss
Affiliation:
Pediatric Cardiology, Medical College of Wisconsin, Milwaukee, WI, USA
*
Corresponding author: Lubna Hashim; Email: hashimlubna5@gmail.com
Rights & Permissions [Opens in a new window]

Abstract

We report the case of a 60-year-old man with repaired Tetralogy of Fallot and long-standing severe pulmonary insufficiency, complicated by asymmetric pulmonary blood flow and anatomy unsuitable for standard right ventricular outflow tract valve implantation. Cardiac imaging demonstrated a pyramidal right ventricular outflow tract that did not meet the oversizing criteria for a Harmony TPV 25, with the lack of interference with the inflow part of the device. In addition, the left pulmonary artery was severely hypoplastic with proximal stenosis. To avoid jailing the left pulmonary artery and high-risk unstable right ventricular outflow tract implant, a transcatheter Harmony valve was deployed in the right pulmonary artery while protecting the left pulmonary artery, followed by stenting of the left pulmonary artery. The goal was to ultimately eliminate the vast majority of pulmonary insufficiency and maintain antegrade flow across the left pulmonary artery. Hemodynamics demonstrated elevated right-sided pressures prior to intervention, which improved post-procedure. The patient tolerated the procedure well, with a transient postoperative diuretic requirement. At 10-month follow-up, he remained asymptomatic with improved left ventricular ejection fraction and a well-functioning Harmony valve on echocardiography. This case highlights the feasibility of branch pulmonary artery valve implantation using the Harmony valve in patients with unfavourable right ventricular outflow tract anatomy and demonstrates the value of simultaneous left pulmonary artery stenting to maintain relatively balanced pulmonary perfusion. Transcatheter branch pulmonary artery implantation may represent a viable option in carefully selected patients for whom conventional right ventricular outflow tract implantation is not possible.

Information

Type
Case Report
Copyright
© The Author(s), 2026. Published by Cambridge University Press
Figure 0

Figure 1. Figure 1 long description.(a) CTA 3D reconstruction showing the severely hypoplastic LPA (black arrow pointing to the origin of LPA). (b) and (c) perimeter plot and virtual implant in the RVOT demonstrated the poor interference of the inflow part of TPV 25 Harmony valve and high potential risk for jailing LPA (Black arrow).

Figure 1

Figure 2. Figure 2 long description.Repeat analysis of RPA implant showing good candidacy for TPV 25 Harmony valve with continued concerns for jailing LPA (White arrow).

Figure 2

Figure 3. Figure 3 long description.Cross-sectional measurements of both RVOT and RPA at different levels as shown by the multiple blue dots. The left panel for RVOT and right panel for the RPA.

Figure 3

Figure 4. Figure 4 long description.Series of procedural angiograms: (a) Baseline RPA anatomy while LPA wire protection. White arrow showing the LPA origin (Projection RAO/cranial). (b) Repeat angiogram after fully exposed Harmony valve and before release showing the proximity of inflow portion of the device to the LPA (White arrow). The White start pointing to the most distal portion of the outflow part of the device by the RPA bifurcation (Projection RAO/cranial). (c) Post-LPA stenting angiogram confirming positioning and patency of LPA (White arrow). The white stars most distal part of the device by the RPA bifurcation and the other star most proximal part of the inflow part of the device in the RVOT (Projection LAO/cranial).

Figure 4

Figure 5. Figure 5 long description.Follow-up CT scan demonstrated a well-positioned Harmony valve (A) and patent and well-positioned LPA stent.